UVU-NZM

Delay unit

Trade Price

£620.97

Per

1

Unit

EACH

Pack Quantity

1

UVU-NZM

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Delay unit

Technical Specifications

Product Length/Depth

100 mm

Product Height

114 mm

Product Width

74 mm

Product Weight

0.847 kg

Compliances

IEC

RoHS conform

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Frame

NZM1/2/3/4

Rated control supply voltage (Us) at AC, 50 Hz - min

24 V

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Suitable for

Off-load switch

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Voltage rating at AC

220 - 550 V AC

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Rated control supply voltage (Us) at DC - min

24 V

Delay time

70 - 4000 ms (undervoltage releases, off-delayed)

Power consumption

50 VA

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

Rated control supply voltage (Us) at AC, 50 Hz - max

550 V

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

Connection type

With bolt connection

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Special features

Delay unit for combination with special undervoltage releases.

For use with emergency-stop devices in connection with an emergency-stop button.

not UL/CSA approved

Voltage dips of less than the setting between 0.06 – 16 s do not cause disconnection of the NZM circuit-breaker or N switch-disconnector.

Delay time can be set from: 70 ms – 4 s.

With additional external capacitor: 30,000 µF ≧ 35 V to 8 s, 90,000 µF ≧ 35 V to 16 s.

A special release is required.

Cannot be installed simultaneously with separate NZM...-XHIV early-make auxiliary contact or NZM...-XA... shunt release.

Delay unit for separate installation. Fixing: top-hat rail or screws.

For other operating voltages use a control transformer.

Rated operation current (Ie)

< 0.5 A

Undelayed short-circuit release - min

0 A

Rated control supply voltage (Us) at AC, 60 Hz - min

24 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Terminal capacity (solid/flexible conductor)

20 - 14 AWG (1x) at shunt release

20 - 16 AWG (2x) at shunt release

0.5 mm² - 1.5 mm² (2x) at shunt release with ferrule

0.5 mm² - 1.5 mm² (2x) for undervoltage releases, off-delayed with ferrule

0.5 mm² - 2.5 mm² (1x) at shunt release with ferrule

18 - 14 AWG (1x) for undervoltage releases, off-delayed

0.5 mm² - 2.5 mm² (1x) for undervoltage releases, off-delayed with ferrule

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Voltage rating at DC

24 V DC

Functions

Delayed

Rated control supply voltage (Us) at DC - max

24 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Delay time with additional external capacitor

8 s (30 mF)

16 s (90 mF)

Type

Accessory

Undervoltage release

Undervoltage release, off-delayed

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Rated control supply voltage (Us) at AC, 60 Hz - max

550 V

Used with

N(S)1(-4), 2(-4), 3(-4), 4(-4)

50/60 Hz

220 V - 240 V

380 V - 440 V

480 V - 550 V

DC/AC

24 V

NZM1(-4), 2(-4), 3(-4), 4(-4)

N(S)1(-4), 2(-4), 3(-4), 4(-4)

50/60 Hz

220 V - 240 V

380 V - 440 V

480 V - 550 V

DC/AC

24 V

Number of contacts (normally open contacts)

0

Undelayed short-circuit release - max

0 A

Electric connection type

Screw connection

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Number of contacts (normally closed contacts)

0

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Number of contacts (change-over contacts)

0

Voltage type

AC/DC

Document Links

Datasheet