NZM4-XHIV

Auxiliary, 2N/O(EM), screw terms

Trade Price

£98.08

Per

1

Unit

EACH

Pack Quantity

1

NZM4-XHIV

Information

Eaton Moeller series NZM - Molded Case Circuit Breaker. Auxiliary contact, 2early N/O, operates as an early-make contact, 4

Technical Specifications

Product Length/Depth

107 mm

Product Height

51 mm

Product Width

64 mm

Product Weight

0.129 kg

Compliances

RoHS conform

Certifications

IEC60947

CSA certified

CSA (Class No. 1437-01)

UL489

CE marking

UL listed

CSA (File No. 22086)

UL (File No. E140305)

UL (Category Control Number DIHS)

CSA-C22.2 No. 5-09

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Lamp holder

None

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Mounting Method

Other

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Voltage rating at AC

500 V AC

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.8 Connections for external conductors

Is the panel builder's responsibility.

Connection type

Screw

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Special features

C300/R300 (auxiliary contacts, UL/CSA, pilot duty)

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Terminal capacity (solid/flexible conductor)

0.75 mm² - 2.5 mm² (2x) at auxiliary contacts with ferrule

0.75 mm² - 2.5 mm² (1x) at auxiliary contacts with ferrule

18 - 14 AWG (1x) at auxiliary contacts

18 - 14 AWG (2x) at auxiliary contacts

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Voltage rating at DC

220 VDC

Fuse short-circuit protection - max

10 A gG/gL

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Used with

FAZ-B6 (max. miniature circuit breaker)

Number of contacts (normally open contacts)

2

Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V

4 A

Model

Integrable

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Conventional thermal current Ith of auxiliary contacts

4 A

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Number of contacts (normally closed contacts)

0

Rated operational current

2.5 A at 240 V AC (UL/CSA)

1 A at 250 V DC (UL/CSA)

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Number of contacts (change-over contacts)

0