Eaton Moeller series NZM - Molded Case Circuit Breaker. Auxiliary contact, 2early N/O, operates as an early-make contact, 4
Product Length/Depth
107 mm
Product Height
51 mm
Product Width
64 mm
Product Weight
0.129 kg
Compliances
RoHS conform
Certifications
IEC60947
CSA certified
CSA (Class No. 1437-01)
UL489
CE marking
UL listed
CSA (File No. 22086)
UL (File No. E140305)
UL (Category Control Number DIHS)
CSA-C22.2 No. 5-09
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Lamp holder
None
10.4 Clearances and creepage distances
Meets the product standard's requirements.
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Mounting Method
Other
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Voltage rating at AC
500 V AC
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
10.8 Connections for external conductors
Is the panel builder's responsibility.
Connection type
Screw
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Special features
C300/R300 (auxiliary contacts, UL/CSA, pilot duty)
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Terminal capacity (solid/flexible conductor)
0.75 mm² - 2.5 mm² (2x) at auxiliary contacts with ferrule
0.75 mm² - 2.5 mm² (1x) at auxiliary contacts with ferrule
18 - 14 AWG (1x) at auxiliary contacts
18 - 14 AWG (2x) at auxiliary contacts
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Voltage rating at DC
220 VDC
Fuse short-circuit protection - max
10 A gG/gL
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Used with
FAZ-B6 (max. miniature circuit breaker)
Number of contacts (normally open contacts)
2
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
4 A
Model
Integrable
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
Conventional thermal current Ith of auxiliary contacts
4 A
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Number of contacts (normally closed contacts)
0
Rated operational current
2.5 A at 240 V AC (UL/CSA)
1 A at 250 V DC (UL/CSA)
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Number of contacts (change-over contacts)
0
Datasheet