DILMC7-10(*VDC)

Contactor, 3-pole+1N/O, 3kW

Trade Price

£45.90

Per

1

Unit

EACH

Pack Quantity

1

DILMC7-10(*VDC)
DILMC7-10(*VDC)
DILMC7-10(*VDC)
DILMC7-10(*VDC)

Information

Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 3 kW, 1 N/O, *V DC, DC operation, Spring-loaded terminals

Technical Specifications

Product Length/Depth

75 mm

Product Height

68 mm

Product Width

45 mm

Product Weight

0.286 kg

Certifications

UL

IEC/EN 60947-4-1

UL File No.: E29096

CE

CSA File No.: 012528

CSA Class No.: 2411-03, 3211-04

VDE 0660

UL 60947-4-1

IEC/EN 60947

CSA

CSA-C22.2 No. 60947-4-1-14

UL Category Control No.: NLDX

Catalog Notes

Contacts according to EN 50012

Terminal capacity (flexible with ferrule)

1 x (0.75 - 1.5) mm²

2 x (0.75 - 1.5) mm²

Rated operational current for specified heat dissipation (In)

7 A

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Rated operational power at AC-3, 380/400 V, 50 Hz

3 kW

Conventional thermal current ith (3-pole, enclosed)

18 A

Rated operational power at AC-4, 380/400 V, 50 Hz

2.2 kW

Rated operational current (Ie) at AC-4, 440 V

5 A

Rated control supply voltage (Us) at AC, 50 Hz - min

0 V

Conventional thermal current ith at 60°C (3-pole, open)

20 A

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Number of contacts (normally closed) as main contact

0

Short-circuit current rating (high fault at 480 V)

30/100 kA, Fuse, SCCR (UL/CSA)

65 kA, CB, SCCR (UL/CSA)

25 A, Class RK5/ 20 A Class J, max. Fuse, SCCR (UL/CSA)

16 A, max. CB, SCCR (UL/CSA)

Conventional thermal current ith at 55°C (3-pole, open)

21 A

Rated operational power (NEMA)

2.2 kW

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Ambient storage temperature - min

40 °C

Fitted with:

Varistor suppressor circuit

Rated breaking capacity at 380/400 V

70 A

Short-circuit current rating (basic rating)

45 A, max. Fuse, SCCR (UL/CSA)

60 A, max. CB, SCCR (UL/CSA)

5 kA, SCCR (UL/CSA)

Rated control supply voltage (Us) at AC, 50 Hz - max

0 V

Rated breaking capacity at 660/690 V

40 A

Rated operational current (Ie) at DC-1, 220 V

15 A

Special purpose rating of elevator control

0.75 HP, 200 V 60 Hz 3-ph, (UL/CSA)

3.7 A, 200 V 60 Hz 3-ph, (UL/CSA)

2 HP, 480 V 60 Hz 3-ph, (UL/CSA)

3.4 A, 480 V 60 Hz 3-ph, (UL/CSA)

1.5 HP, 240 V 60 Hz 3-ph, (UL/CSA)

3 HP, 600 V 60 Hz 3-ph, (UL/CSA)

3.9 A, 600 V 60 Hz 3-ph, (UL/CSA)

6 A, 240 V 60 Hz 3-ph, (UL/CSA)

Ambient operating temperature - max

60 °C

Assigned motor power at 115/120 V, 60 Hz, 1-phase

0.25 HP

Rated operational power at AC-4, 440 V, 50 Hz

2.4 kW

Electrical connection type of main circuit

Spring clamp connection

Power consumption (sealing) at DC

3 W

Number Of Poles

Three-pole

Ambient operating temperature - min

-25 °C

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

Terminal capacity (flexible)

1 x (0.75 - 2.5) mm²

2 x (0.75 - 2.5) mm²

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Application

Contactors for Motors

Operating frequency

9000 mechanical Operations/h (DC operated)

Voltage type

DC

Short-circuit protection rating (type 1 coordination) at 400 V

35 A gG/gL

Product category

Contactors

Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V

5 A

Rated operational power at AC-3, 690 V, 50 Hz

3.5 kW

Heat dissipation capacity Pdiss

0 W

Assigned motor power at 460/480 V, 60 Hz, 3-phase

3 HP

Special purpose rating of tungsten incandescent lamps

14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)

14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)

Rated operational current (Ie) at AC-4, 500 V

4.5 A

Rated operational power at AC-3, 240 V, 50 Hz

2.2 kW

Operating voltage at AC, 60 Hz - max

690 V

Terminal capacity (solid/stranded AWG)

18 - 14

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Degree of protection

IP20

Overvoltage category

III

Ambient storage temperature - max

80 °C

Pollution degree

3

Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V

22 A

Rated impulse withstand voltage (Uimp)

8000 V AC

Connection

Spring-loaded terminals

Operating voltage at AC, 60 Hz - min

24 V

Rated operational power at AC-4, 660/690 V, 50 Hz

2.9 kW

Frame size

FS1

Conventional thermal current ith (1-pole, enclosed)

45 A

Rated operational current (Ie) at AC-3, 660 V, 690 V

4 A

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V

7 A

Number of contacts (normally open contacts)

1

Short-circuit protection rating (type 2 coordination) at 400 V

20 A gG/gL

Special purpose rating of ballast electrical discharge lamps

12 A (600V 60Hz 3phase, 347V 60Hz 1phase)

12 A (480V 60Hz 3phase, 277V 60Hz 1phase)

Number of auxiliary contacts (normally open contacts)

1

Special purpose rating of definite purpose rating

42 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)

7 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)

Rated operational power at AC-3, 500 V, 50 Hz

3.5 kW

Shock resistance

5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms

10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms

3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms

7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

Rated operational current (Ie) at DC-1, 110 V

20 A

Assigned motor power at 230/240 V, 60 Hz, 3-phase

2 HP

Drop-out voltage

At least smoothed two-phase bridge rectifier or three-phase rectifier

0.6 - 0.15 x UC, DC operated

Resistance per pole

4.6 mΩ

Ambient operating temperature (enclosed) - min

25 °C

Stripping length (control circuit cable)

10 mm

Operating voltage at AC, 50 Hz - max

690 V

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Special purpose rating of refrigeration control (CSA only)

60 A, LRA 480 V 60 Hz 3phase; (CSA)

10 A, FLA 480 V 60 Hz 3phase; (CSA)

10 A, FLA 600 V 60 Hz 3phase; (CSA)

60 A, LRA 600 V 60 Hz 3phase; (CSA)

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Stripping length (main cable)

10 mm

Ambient operating temperature (enclosed) - max

40 °C

Special purpose rating of resistance air heating

12 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)

12 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)

Rated control supply voltage (Us) at DC - min

12 V

Short-circuit current rating (high fault at 600 V)

30/100 kA, Fuse, SCCR (UL/CSA)

25 A, Class RK5/20 A, Class J, max. Fuse, SCCR (UL/CSA)

10.8 Connections for external conductors

Is the panel builder's responsibility.

Number of main contacts (normally open contact)

3

Rated breaking capacity at 220/230 V

70 A

Rated operational current (Ie) at AC-4, 400 V

5 A

Short-circuit protection rating (type 2 coordination) at 690 V

16 A gG/gL

Assigned motor power at 575/600 V, 60 Hz, 3-phase

5 HP

Protection

Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)

Rated operational power at AC-3, 440 V, 50 Hz

4.5 kW

Rated breaking capacity at 500 V

50 A

Rated operational power at AC-3, 415 V, 50 Hz

4 kW

Climatic proofing

Damp heat, cyclic, to IEC 60068-2-30

Damp heat, constant, to IEC 60068-2-78

Emitted interference

According to EN 60947-1

Connection to SmartWire-DT

No

Static heat dissipation, non-current-dependent Pvs

3 W

Rated control supply voltage (Us) at DC - max

250 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

Utilization category

AC-1: Non-inductive or slightly inductive loads, resistance furnaces

AC-3: Normal AC induction motors: starting, switch off during running

AC-4: Normal AC induction motors: starting, plugging, reversing, inching

Rated operational current (Ie) at AC-3, 440 V

7 A

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Safe isolation

400 V AC, Between coil and contacts, According to EN 61140

400 V AC, Between the contacts, According to EN 61140

Operating voltage at AC, 50 Hz - min

24 V

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Heat dissipation per pole, current-dependent Pvid

0.1 W

Actuating voltage

*V DC

Switching time (DC operated, make contacts, opening delay) - max

12 ms

Switching capacity (auxiliary contacts, general use)

1 A, 250 V DC, (UL/CSA)

10 A, 600 V AC, (UL/CSA)

Switching time (DC operated, make contacts, closing delay) - max

31 ms

Rated operational current (Ie) at AC-4, 660 V, 690 V

4 A

Equipment heat dissipation, current-dependent Pvid

0 W

Assigned motor power at 200/208 V, 60 Hz, 3-phase

1.5 HP

Pick-up voltage

0.8 - 1.1 V DC x Uc

0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts)

Suitable for

Also motors with efficiency class IE3

Conventional thermal current ith at 40°C (3-pole, open)

22 A

Terminal capacity (solid)

2 x (0.75 - 2.5) mm²

1 x (0.75 - 2.5) mm²

Number of auxiliary contacts (normally closed contacts)

0

Interference immunity

According to EN 60947-1

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

Lifespan, mechanical

10,000,000 Operations (DC operated)

Short-circuit protection rating (type 1 coordination) at 690 V

20 A gG/gL

Rated making capacity up to 690 V (cos phi to IEC/EN 60947)

112 A

Rated operational power at AC-4, 240 V, 50 Hz

1.5 kW

Rated operational power at AC-4, 500 V, 50 Hz

2.5 kW

Rated operational current (Ie) at DC-1, 60 V

20 A

Rated operational power at AC-4, 220/230 V, 50 Hz

1 kW

Rated operational voltage (Ue) at AC - max

690 V

Rated control supply voltage (Us) at AC, 60 Hz - min

0 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

Power consumption (pick-up) at DC

3 W

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Switching capacity (main contacts, general use)

20 A, Maximum motor rating (UL/CSA)

Conventional thermal current ith at 50°C (3-pole, open)

21 A

Rated operational current (Ie) at AC-3, 500 V

5 A

Assigned motor power at 230/240 V, 60 Hz, 1-phase

1 HP

Screwdriver size

3.5 mm, Spring-loaded terminals

Duty factor

100 %

Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V

7 A

Conventional thermal current ith of main contacts (1-pole, open)

50 A

Rated control supply voltage (Us) at AC, 60 Hz - max

0 V

Arcing time

10 ms

Rated operational power at AC-4, 415 V, 50 Hz

2.3 kW

Switching capacity (auxiliary contacts, pilot duty)

A600, AC operated (UL/CSA)

P300, DC operated (UL/CSA)

Rated insulation voltage (Ui)

690 V

Altitude

Max. 2000 m

Document Links

Datasheet