Eaton Moeller® series DILM Contactor, 3 pole, 380 V 400 V 3 kW, 1 N/O, *V DC, DC operation, Spring-loaded terminals
Product Length/Depth
75 mm
Product Height
68 mm
Product Width
45 mm
Product Weight
0.286 kg
Certifications
UL
IEC/EN 60947-4-1
UL File No.: E29096
CE
CSA File No.: 012528
CSA Class No.: 2411-03, 3211-04
VDE 0660
UL 60947-4-1
IEC/EN 60947
CSA
CSA-C22.2 No. 60947-4-1-14
UL Category Control No.: NLDX
Catalog Notes
Contacts according to EN 50012
Terminal capacity (flexible with ferrule)
1 x (0.75 - 1.5) mm²
2 x (0.75 - 1.5) mm²
Rated operational current for specified heat dissipation (In)
7 A
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Rated operational power at AC-3, 380/400 V, 50 Hz
3 kW
Conventional thermal current ith (3-pole, enclosed)
18 A
Rated operational power at AC-4, 380/400 V, 50 Hz
2.2 kW
Rated operational current (Ie) at AC-4, 440 V
5 A
Rated control supply voltage (Us) at AC, 50 Hz - min
0 V
Conventional thermal current ith at 60°C (3-pole, open)
20 A
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Number of contacts (normally closed) as main contact
0
Short-circuit current rating (high fault at 480 V)
30/100 kA, Fuse, SCCR (UL/CSA)
65 kA, CB, SCCR (UL/CSA)
25 A, Class RK5/ 20 A Class J, max. Fuse, SCCR (UL/CSA)
16 A, max. CB, SCCR (UL/CSA)
Conventional thermal current ith at 55°C (3-pole, open)
21 A
Rated operational power (NEMA)
2.2 kW
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Ambient storage temperature - min
40 °C
Fitted with:
Varistor suppressor circuit
Rated breaking capacity at 380/400 V
70 A
Short-circuit current rating (basic rating)
45 A, max. Fuse, SCCR (UL/CSA)
60 A, max. CB, SCCR (UL/CSA)
5 kA, SCCR (UL/CSA)
Rated control supply voltage (Us) at AC, 50 Hz - max
0 V
Rated breaking capacity at 660/690 V
40 A
Rated operational current (Ie) at DC-1, 220 V
15 A
Special purpose rating of elevator control
0.75 HP, 200 V 60 Hz 3-ph, (UL/CSA)
3.7 A, 200 V 60 Hz 3-ph, (UL/CSA)
2 HP, 480 V 60 Hz 3-ph, (UL/CSA)
3.4 A, 480 V 60 Hz 3-ph, (UL/CSA)
1.5 HP, 240 V 60 Hz 3-ph, (UL/CSA)
3 HP, 600 V 60 Hz 3-ph, (UL/CSA)
3.9 A, 600 V 60 Hz 3-ph, (UL/CSA)
6 A, 240 V 60 Hz 3-ph, (UL/CSA)
Ambient operating temperature - max
60 °C
Assigned motor power at 115/120 V, 60 Hz, 1-phase
0.25 HP
Rated operational power at AC-4, 440 V, 50 Hz
2.4 kW
Electrical connection type of main circuit
Spring clamp connection
Power consumption (sealing) at DC
3 W
Number Of Poles
Three-pole
Ambient operating temperature - min
-25 °C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
Terminal capacity (flexible)
1 x (0.75 - 2.5) mm²
2 x (0.75 - 2.5) mm²
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Application
Contactors for Motors
Operating frequency
9000 mechanical Operations/h (DC operated)
Voltage type
DC
Short-circuit protection rating (type 1 coordination) at 400 V
35 A gG/gL
Product category
Contactors
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V
5 A
Rated operational power at AC-3, 690 V, 50 Hz
3.5 kW
Heat dissipation capacity Pdiss
0 W
Assigned motor power at 460/480 V, 60 Hz, 3-phase
3 HP
Special purpose rating of tungsten incandescent lamps
14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Rated operational current (Ie) at AC-4, 500 V
4.5 A
Rated operational power at AC-3, 240 V, 50 Hz
2.2 kW
Operating voltage at AC, 60 Hz - max
690 V
Terminal capacity (solid/stranded AWG)
18 - 14
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Degree of protection
IP20
Overvoltage category
III
Ambient storage temperature - max
80 °C
Pollution degree
3
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V
22 A
Rated impulse withstand voltage (Uimp)
8000 V AC
Connection
Spring-loaded terminals
Operating voltage at AC, 60 Hz - min
24 V
Rated operational power at AC-4, 660/690 V, 50 Hz
2.9 kW
Frame size
FS1
Conventional thermal current ith (1-pole, enclosed)
45 A
Rated operational current (Ie) at AC-3, 660 V, 690 V
4 A
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V
7 A
Number of contacts (normally open contacts)
1
Short-circuit protection rating (type 2 coordination) at 400 V
20 A gG/gL
Special purpose rating of ballast electrical discharge lamps
12 A (600V 60Hz 3phase, 347V 60Hz 1phase)
12 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Number of auxiliary contacts (normally open contacts)
1
Special purpose rating of definite purpose rating
42 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
7 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Rated operational power at AC-3, 500 V, 50 Hz
3.5 kW
Shock resistance
5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5.7 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
3.4 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
3.4 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27 when tabletop-mounted, Half-sinusoidal shock 10 ms
7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Rated operational current (Ie) at DC-1, 110 V
20 A
Assigned motor power at 230/240 V, 60 Hz, 3-phase
2 HP
Drop-out voltage
At least smoothed two-phase bridge rectifier or three-phase rectifier
0.6 - 0.15 x UC, DC operated
Resistance per pole
4.6 mΩ
Ambient operating temperature (enclosed) - min
25 °C
Stripping length (control circuit cable)
10 mm
Operating voltage at AC, 50 Hz - max
690 V
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Special purpose rating of refrigeration control (CSA only)
60 A, LRA 480 V 60 Hz 3phase; (CSA)
10 A, FLA 480 V 60 Hz 3phase; (CSA)
10 A, FLA 600 V 60 Hz 3phase; (CSA)
60 A, LRA 600 V 60 Hz 3phase; (CSA)
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Stripping length (main cable)
10 mm
Ambient operating temperature (enclosed) - max
40 °C
Special purpose rating of resistance air heating
12 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
12 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Rated control supply voltage (Us) at DC - min
12 V
Short-circuit current rating (high fault at 600 V)
30/100 kA, Fuse, SCCR (UL/CSA)
25 A, Class RK5/20 A, Class J, max. Fuse, SCCR (UL/CSA)
10.8 Connections for external conductors
Is the panel builder's responsibility.
Number of main contacts (normally open contact)
3
Rated breaking capacity at 220/230 V
70 A
Rated operational current (Ie) at AC-4, 400 V
5 A
Short-circuit protection rating (type 2 coordination) at 690 V
16 A gG/gL
Assigned motor power at 575/600 V, 60 Hz, 3-phase
5 HP
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated operational power at AC-3, 440 V, 50 Hz
4.5 kW
Rated breaking capacity at 500 V
50 A
Rated operational power at AC-3, 415 V, 50 Hz
4 kW
Climatic proofing
Damp heat, cyclic, to IEC 60068-2-30
Damp heat, constant, to IEC 60068-2-78
Emitted interference
According to EN 60947-1
Connection to SmartWire-DT
No
Static heat dissipation, non-current-dependent Pvs
3 W
Rated control supply voltage (Us) at DC - max
250 V
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
Utilization category
AC-1: Non-inductive or slightly inductive loads, resistance furnaces
AC-3: Normal AC induction motors: starting, switch off during running
AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Rated operational current (Ie) at AC-3, 440 V
7 A
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Safe isolation
400 V AC, Between coil and contacts, According to EN 61140
400 V AC, Between the contacts, According to EN 61140
Operating voltage at AC, 50 Hz - min
24 V
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Heat dissipation per pole, current-dependent Pvid
0.1 W
Actuating voltage
*V DC
Switching time (DC operated, make contacts, opening delay) - max
12 ms
Switching capacity (auxiliary contacts, general use)
1 A, 250 V DC, (UL/CSA)
10 A, 600 V AC, (UL/CSA)
Switching time (DC operated, make contacts, closing delay) - max
31 ms
Rated operational current (Ie) at AC-4, 660 V, 690 V
4 A
Equipment heat dissipation, current-dependent Pvid
0 W
Assigned motor power at 200/208 V, 60 Hz, 3-phase
1.5 HP
Pick-up voltage
0.8 - 1.1 V DC x Uc
0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts)
Suitable for
Also motors with efficiency class IE3
Conventional thermal current ith at 40°C (3-pole, open)
22 A
Terminal capacity (solid)
2 x (0.75 - 2.5) mm²
1 x (0.75 - 2.5) mm²
Number of auxiliary contacts (normally closed contacts)
0
Interference immunity
According to EN 60947-1
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Lifespan, mechanical
10,000,000 Operations (DC operated)
Short-circuit protection rating (type 1 coordination) at 690 V
20 A gG/gL
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)
112 A
Rated operational power at AC-4, 240 V, 50 Hz
1.5 kW
Rated operational power at AC-4, 500 V, 50 Hz
2.5 kW
Rated operational current (Ie) at DC-1, 60 V
20 A
Rated operational power at AC-4, 220/230 V, 50 Hz
1 kW
Rated operational voltage (Ue) at AC - max
690 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
Power consumption (pick-up) at DC
3 W
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Switching capacity (main contacts, general use)
20 A, Maximum motor rating (UL/CSA)
Conventional thermal current ith at 50°C (3-pole, open)
21 A
Rated operational current (Ie) at AC-3, 500 V
5 A
Assigned motor power at 230/240 V, 60 Hz, 1-phase
1 HP
Screwdriver size
3.5 mm, Spring-loaded terminals
Duty factor
100 %
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V
7 A
Conventional thermal current ith of main contacts (1-pole, open)
50 A
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Arcing time
10 ms
Rated operational power at AC-4, 415 V, 50 Hz
2.3 kW
Switching capacity (auxiliary contacts, pilot duty)
A600, AC operated (UL/CSA)
P300, DC operated (UL/CSA)
Rated insulation voltage (Ui)
690 V
Altitude
Max. 2000 m