DILAC-40(24V50HZ)

Relay, 4N/O, contactor type

Trade Price

£43.70

Per

1

Unit

EACH

Pack Quantity

1

DILAC-40(24V50HZ)
DILAC-40(24V50HZ)
DILAC-40(24V50HZ)
DILAC-40(24V50HZ)

Information

Eaton Moeller® series DILA Contactor relay, 24 V 50 Hz, 4 N/O, Spring-loaded terminals, AC operation

Technical Specifications

Product Length/Depth

75 mm

Product Height

68 mm

Product Width

45 mm

Product Weight

0.225 kg

Compliances

CE Marked

Certifications

IEC 60947-4-1

EN 60947-4-1

UL 508

CSA Std. C22.2 No. 14-05

VDE

CSA-C22.2 No. 14-05

IEC/EN 60947-4-1

CSA File No.: 012528

UL File No.: E29184

CSA Class No.: 3211-03

IEC/EN 60947

CE

UL

EN 60947-5-1

CSA

VDE 0660

UL Category Control No.: NKCR

Catalog Notes

This item can only be ordered until December 31, 2023 with a maximum delivery date of May 31, 2024.

Rated operational current for specified heat dissipation (In)

15.5 A

Terminal capacity (flexible with ferrule)

1 x (0.75 - 1.5) mm², Spring-loaded terminals with or without ferrule DIN 46228

2 x (0.75 - 1.5) mm², Spring-loaded terminals with or without ferrule DIN 46228

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

Rated control supply voltage (Us) at AC, 50 Hz - min

24 V

Conventional thermal current ith at 60°C (3-pole, open)

16 A

10.4 Clearances and creepage distances

Meets the product standard's requirements.

Mounting method

DIN rail

Operating voltage at DC - max

220 VDC

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

Ambient storage temperature - min

40 °C

Fitted with:

Positive operation contacts

Rated control supply voltage (Us) at AC, 50 Hz - max

24 V

Operating voltage at DC - min

24 VDC

Ambient operating temperature - max

60 °C

Features

Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module

Ambient operating temperature - min

-25 °C

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

Application

Contactor relays

Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V

4 A

Operating frequency

9000 Operations/h

Voltage type

AC

Product category

DILA relays

Power consumption, pick-up, 50 Hz

24 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz

Heat dissipation capacity Pdiss

0 W

Connection type (auxiliary circuit)

Spring clamp connection

Short-circuit protection rating without welding

10 A gG/gL, 500 V, Max. Fuse, Contacts

Switching time (AC operated, make contacts, opening delay) - min

9 ms

Operating voltage at AC, 60 Hz - max

500 V

Terminal capacity (solid/stranded AWG)

18 - 14, Spring-loaded terminals

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

Degree of protection

IP20

Overvoltage category

III

Switching time (AC operated, make contacts, opening delay) - max

18 ms

Ambient storage temperature - max

80 °C

Voltage type of operating voltage

AC/DC

Pollution degree

3

Power consumption, pick-up, 60 Hz

24 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz

Switching time (AC operated, make contacts, closing delay) - max

21 ms

Rated impulse withstand voltage (Uimp)

6000 V AC

Connection

Spring-loaded terminals

Operating voltage at AC, 60 Hz - min

17 V

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.7 Inscriptions

Meets the product standard's requirements.

Number of contacts (normally open contacts)

4

Switching time (AC operated, make contacts, closing delay) - min

15 ms

Number of auxiliary contacts (normally open contacts)

4

Shock resistance

7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms

Power consumption, sealing, 60 Hz

1.4 W, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz

Ambient operating temperature (enclosed) - min

25 °C

Operating voltage at AC, 50 Hz - max

500 V

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

Number of auxiliary contacts (normally closed contacts, delayed switching)

0

Stripping length (main cable)

10 mm

Ambient operating temperature (enclosed) - max

40 °C

Rated control supply voltage (Us) at DC - min

0 V

10.8 Connections for external conductors

Is the panel builder's responsibility.

Number of auxiliary contacts (normally open contacts, leading)

0

Protection

Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)

Power consumption, sealing, 50 Hz

1.4 W, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz

3.4 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz

Climatic proofing

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Code number

40D

Connection to SmartWire-DT

No

Static heat dissipation, non-current-dependent Pvs

1.4 W

Rated operational current (Ie) at AC-15, 500 V

1.5 A

Rated control supply voltage (Us) at DC - max

0 V

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

Safe isolation

400 V AC, Between auxiliary contacts, According to EN 61140

400 V AC, Between coil and auxiliary contacts, According to EN 61140

Operating voltage at AC, 50 Hz - min

17 V

Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V

4 A

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

Number of contacts (normally closed contacts)

0

Heat dissipation per pole, current-dependent Pvid

0.5 W

Actuating voltage

24 V 50 Hz

Switching capacity (auxiliary contacts, general use)

15 A, 600 V AC, (UL/CSA)

1 A, 250 V DC, (UL/CSA)

Equipment heat dissipation, current-dependent Pvid

0 W

Rated switch current

16 A

Rated operational current (Ie)

10 A at 24 V, DC L/R <= 15 ms (with 1 contact in series)

5 A at 220 V, DC L/R <= 15 ms (with 3 contacts in series)

4 A at 60 V, DC L/R <= 50 ms (with 3 contacts in series)

6 A at 110 V, DC L/R <= 15 ms (with 3 contacts in series)

1 A at 220 V, DC L/R <= 15 ms (with 1 contact in series)

10 A at 60 V, DC L/R <= 15 ms (with 2 contacts in series)

3 A at 110 V, DC L/R <= 15 ms (with 1 contact in series)

6 A at 60 V, DC L/R <= 15 ms (with 1 contact in series)

2 A at 110 V, DC L/R <= 50 ms (with 3 contacts in series)

1 A at 220 V, DC L/R <= 50 ms (with 3 contacts in series)

4 A at 24 V, DC L/R <= 50 ms (with 3 contacts in series)

16 A

Pick-up voltage

0.8 - 1.1 V AC x Uc (voltage tolerance - single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz)

Terminal capacity (solid)

2 x (0.75 - 2.5) mm², Spring-loaded terminals

1 x (0.75 - 2.5) mm², Spring-loaded terminals

Number of auxiliary contacts (normally closed contacts)

0

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

Lifespan, mechanical

20,000,000 Operations (AC operated)

Control circuit reliability

λ < 5 x 10-7 (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)

Number of auxiliary contacts (change-over contacts)

0

Rated operational voltage (Ue) at AC - max

690 V

Rated control supply voltage (Us) at AC, 60 Hz - min

0 V

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

Screwdriver size

0.6 x 3.5 mm, Spring-loaded terminals

Duty factor

100 %

Rated control supply voltage (Us) at AC, 60 Hz - max

0 V

Switching capacity (auxiliary contacts, pilot duty)

A600, AC operated (UL/CSA)

P300, DC operated (UL/CSA)

Rated insulation voltage (Ui)

690 V

Document Links

Datasheet