Eaton Moeller® series DILA Contactor relay, 24 V 50 Hz, 4 N/O, Spring-loaded terminals, AC operation
Product Length/Depth
75 mm
Product Height
68 mm
Product Width
45 mm
Product Weight
0.225 kg
Compliances
CE Marked
Certifications
IEC 60947-4-1
EN 60947-4-1
UL 508
CSA Std. C22.2 No. 14-05
VDE
CSA-C22.2 No. 14-05
IEC/EN 60947-4-1
CSA File No.: 012528
UL File No.: E29184
CSA Class No.: 3211-03
IEC/EN 60947
CE
UL
EN 60947-5-1
CSA
VDE 0660
UL Category Control No.: NKCR
Catalog Notes
This item can only be ordered until December 31, 2023 with a maximum delivery date of May 31, 2024.
Rated operational current for specified heat dissipation (In)
15.5 A
Terminal capacity (flexible with ferrule)
1 x (0.75 - 1.5) mm², Spring-loaded terminals with or without ferrule DIN 46228
2 x (0.75 - 1.5) mm², Spring-loaded terminals with or without ferrule DIN 46228
10.11 Short-circuit rating
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
Rated control supply voltage (Us) at AC, 50 Hz - min
24 V
Conventional thermal current ith at 60°C (3-pole, open)
16 A
10.4 Clearances and creepage distances
Meets the product standard's requirements.
Mounting method
DIN rail
Operating voltage at DC - max
220 VDC
10.2.3.1 Verification of thermal stability of enclosures
Meets the product standard's requirements.
Ambient storage temperature - min
40 °C
Fitted with:
Positive operation contacts
Rated control supply voltage (Us) at AC, 50 Hz - max
24 V
Operating voltage at DC - min
24 VDC
Ambient operating temperature - max
60 °C
Features
Positive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module
Ambient operating temperature - min
-25 °C
10.6 Incorporation of switching devices and components
Does not apply, since the entire switchgear needs to be evaluated.
10.2.6 Mechanical impact
Does not apply, since the entire switchgear needs to be evaluated.
10.3 Degree of protection of assemblies
Does not apply, since the entire switchgear needs to be evaluated.
Application
Contactor relays
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V
4 A
Operating frequency
9000 Operations/h
Voltage type
AC
Product category
DILA relays
Power consumption, pick-up, 50 Hz
24 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Heat dissipation capacity Pdiss
0 W
Connection type (auxiliary circuit)
Spring clamp connection
Short-circuit protection rating without welding
10 A gG/gL, 500 V, Max. Fuse, Contacts
Switching time (AC operated, make contacts, opening delay) - min
9 ms
Operating voltage at AC, 60 Hz - max
500 V
Terminal capacity (solid/stranded AWG)
18 - 14, Spring-loaded terminals
10.9.2 Power-frequency electric strength
Is the panel builder's responsibility.
Degree of protection
IP20
Overvoltage category
III
Switching time (AC operated, make contacts, opening delay) - max
18 ms
Ambient storage temperature - max
80 °C
Voltage type of operating voltage
AC/DC
Pollution degree
3
Power consumption, pick-up, 60 Hz
24 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Switching time (AC operated, make contacts, closing delay) - max
21 ms
Rated impulse withstand voltage (Uimp)
6000 V AC
Connection
Spring-loaded terminals
Operating voltage at AC, 60 Hz - min
17 V
10.2.2 Corrosion resistance
Meets the product standard's requirements.
10.2.4 Resistance to ultra-violet (UV) radiation
Meets the product standard's requirements.
10.2.7 Inscriptions
Meets the product standard's requirements.
Number of contacts (normally open contacts)
4
Switching time (AC operated, make contacts, closing delay) - min
15 ms
Number of auxiliary contacts (normally open contacts)
4
Shock resistance
7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Power consumption, sealing, 60 Hz
1.4 W, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Ambient operating temperature (enclosed) - min
25 °C
Operating voltage at AC, 50 Hz - max
500 V
10.12 Electromagnetic compatibility
Is the panel builder's responsibility. The specifications for the switchgear must be observed.
10.2.5 Lifting
Does not apply, since the entire switchgear needs to be evaluated.
Number of auxiliary contacts (normally closed contacts, delayed switching)
0
Stripping length (main cable)
10 mm
Ambient operating temperature (enclosed) - max
40 °C
Rated control supply voltage (Us) at DC - min
0 V
10.8 Connections for external conductors
Is the panel builder's responsibility.
Number of auxiliary contacts (normally open contacts, leading)
0
Protection
Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Power consumption, sealing, 50 Hz
1.4 W, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
3.4 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Climatic proofing
Damp heat, constant, to IEC 60068-2-78
Damp heat, cyclic, to IEC 60068-2-30
Code number
40D
Connection to SmartWire-DT
No
Static heat dissipation, non-current-dependent Pvs
1.4 W
Rated operational current (Ie) at AC-15, 500 V
1.5 A
Rated control supply voltage (Us) at DC - max
0 V
10.9.3 Impulse withstand voltage
Is the panel builder's responsibility.
10.5 Protection against electric shock
Does not apply, since the entire switchgear needs to be evaluated.
Safe isolation
400 V AC, Between auxiliary contacts, According to EN 61140
400 V AC, Between coil and auxiliary contacts, According to EN 61140
Operating voltage at AC, 50 Hz - min
17 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V
4 A
10.13 Mechanical function
The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.
10.9.4 Testing of enclosures made of insulating material
Is the panel builder's responsibility.
Number of contacts (normally closed contacts)
0
Heat dissipation per pole, current-dependent Pvid
0.5 W
Actuating voltage
24 V 50 Hz
Switching capacity (auxiliary contacts, general use)
15 A, 600 V AC, (UL/CSA)
1 A, 250 V DC, (UL/CSA)
Equipment heat dissipation, current-dependent Pvid
0 W
Rated switch current
16 A
Rated operational current (Ie)
10 A at 24 V, DC L/R <= 15 ms (with 1 contact in series)
5 A at 220 V, DC L/R <= 15 ms (with 3 contacts in series)
4 A at 60 V, DC L/R <= 50 ms (with 3 contacts in series)
6 A at 110 V, DC L/R <= 15 ms (with 3 contacts in series)
1 A at 220 V, DC L/R <= 15 ms (with 1 contact in series)
10 A at 60 V, DC L/R <= 15 ms (with 2 contacts in series)
3 A at 110 V, DC L/R <= 15 ms (with 1 contact in series)
6 A at 60 V, DC L/R <= 15 ms (with 1 contact in series)
2 A at 110 V, DC L/R <= 50 ms (with 3 contacts in series)
1 A at 220 V, DC L/R <= 50 ms (with 3 contacts in series)
4 A at 24 V, DC L/R <= 50 ms (with 3 contacts in series)
16 A
Pick-up voltage
0.8 - 1.1 V AC x Uc (voltage tolerance - single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz)
Terminal capacity (solid)
2 x (0.75 - 2.5) mm², Spring-loaded terminals
1 x (0.75 - 2.5) mm², Spring-loaded terminals
Number of auxiliary contacts (normally closed contacts)
0
10.2.3.2 Verification of resistance of insulating materials to normal heat
Meets the product standard's requirements.
10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects
Meets the product standard's requirements.
Lifespan, mechanical
20,000,000 Operations (AC operated)
Control circuit reliability
λ < 5 x 10-7 (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
Number of auxiliary contacts (change-over contacts)
0
Rated operational voltage (Ue) at AC - max
690 V
Rated control supply voltage (Us) at AC, 60 Hz - min
0 V
10.7 Internal electrical circuits and connections
Is the panel builder's responsibility.
10.10 Temperature rise
The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.
Screwdriver size
0.6 x 3.5 mm, Spring-loaded terminals
Duty factor
100 %
Rated control supply voltage (Us) at AC, 60 Hz - max
0 V
Switching capacity (auxiliary contacts, pilot duty)
A600, AC operated (UL/CSA)
P300, DC operated (UL/CSA)
Rated insulation voltage (Ui)
690 V