1SDA068133R1

XT4N 160 Ekip LSI In=63A 3p F F

Trade Price

£647.09

Per

1

Unit

EA

Pack Quantity

1

1SDA068133R1
1SDA068133R1
1SDA068133R1
1SDA068133R1

Information

C.BREAKER TMAX XT4N 250 FIXED THREE-POLE WITH FRONT TERMINALS AND SOLID-STATE RELEASE IN AC EKIP-LSI R 63 A

Technical Specifications

ABB EcoSolutions

Yes

Circular Design Principles Recyclability Rate

Design for Closing Resource Loops - Standard EN45555 - 58.5 %

Group Waste to Landfill Target

UL 2799 Zero Waste To Landfill Validation available

RoHS Status

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Order Code US and Canada

XT4NE3063FFF000XXX

EAN

8015644020309

Minimum Order Quantity

1 piece

Customs Tariff Number

85362090

Product Net Width

105 mm

Product Net Height

160 mm

Product Net Depth / Length

82.5 mm

Product Net Weight

2.5 kg

Package Level 1 Units

box 1 piece

Package Level 1 Width

145 mm

Package Level 1 Height

210 mm

Package Level 1 Depth / Length

168 mm

Package Level 1 Gross Weight

2.5 kg

Package Level 1 EAN

8015644020309

Circuit Breaker Type to be Associated

Power Distribution

Connecting Capacity Main Circuit

Busbar 85..200 mm²

Current Type

AC

Electrical Durability

120 cycles per hour8000 cycle

Mechanical Durability

240 cycles per hour25000 cycle

Number of Poles

3

Opening Time

CB with SOR 15 msCB with UVR 15 ms

Order Multiple

1 piece

Power Loss

at Rated Operating Conditions per Pole 1.40 W

Product Main Type

SACE Tmax XT

Product Name

Moulded Case Circuit Breaker

Product Type

Automatic Circuit Breaker

Rated Current (In)

63 A

Rated Frequency (f)

50/60 Hz

Rated Voltage (Ur)

690 V AC

Rated Impulse Withstand Voltage (Uimp)

8 kV

Rated Insulation Voltage (Ui)

1000 V AC

Rated Operational Voltage

690 V AC

Rated Service Short-Circuit Breaking Capacity (Ics)

(220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 20 kA(690 V AC) 10 kA

Rated Ultimate Short-Circuit Breaking Capacity (Icu)

(220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 20 kA(690 V AC) 10 kA

Rated Uninterrupted Current (Iu)

160 A

Recommended Screw Driver

Main Circuit M8

Release

Ekip LSI

Release Type

EL

Short-Circuit Performance Level

N

Standards

IEC

Sub-type

XT4

Terminal Connection Type

Front

Terminal Type

Bolt

Tightening Torque

8 N·m

Version

F

ETIM 7

EC000228 - Power circuit-breaker for trafo/generator/installation protection

ETIM 8

EC000228 - Power circuit-breaker for trafo/generator/installation protection

ETIM 9

EC000228 - Power circuit-breaker for trafo/generator/installation protection

Object Classification Code

Q

UNSPSC

39120000

WEEE Category

5. Small Equipment (No External Dimension More Than 50 cm)

eClass

V11.1 : 27370409

Document Links

Catalogue page

Datasheet