C.BREAKER TMAX XT1N 160 FIXED FOUR-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 80-800 A
ABB EcoSolutions
Yes
Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Group Waste to Landfill Target
UL 2799 Zero Waste To Landfill Validation available
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
38ea6003-efeb-440b-8258-294c4647d79c Italy (IT)
Simplified SCIP
13d4e4b4-a0b7-4b0e-a670-bf1e01e9dc3d Poland (PL)383e131d-8ac9-464b-891c-edec40806df8 Norway (NO)4edfba22-9fdd-4b59-8ab8-17d5ad0e1490 Finland (FI)fa2a42d4-3bc2-4227-a0c8-cd97d76849db Netherlands (NL)ed0d7f17-8e19-4ea9-a0c0-ae7a50079494 Germany (DE)d5a17c63-7902-4635-832b-0cb8363bedac Denmark (DK)f0964070-7e0c-4541-9359-2d1975aa9945 Germany (DE)54f8c0e4-78d5-4efc-bb4a-e7bf97518408 Croatia (HR)7508a0e6-9533-4ab0-bfe5-bc229327607a Czech Republic (CZ)a9f952fd-daf0-4a35-9c2f-b2a31a011ae8 Poland (PL)18281490-6f95-4f80-a336-0e6b162be180 Netherlands (NL)d308258b-32b9-4087-bf09-6a66e3109ef4 Netherlands (NL)0a45d19b-4a2a-440f-af7c-53ac264325b3 Estonia (EE)fdd57062-d9fc-4bfd-9079-4a3a96ea94b1 Greece (GR)fb836575-46ef-4da4-9067-d404dc5946bb Portugal (PT)c67644e0-dda8-4107-b8e9-978fdcebea28 Sweden (SE)11f8b80f-ea71-4297-a53f-4258d5d3b90f Germany (DE)1259445e-a1fd-4893-9b9f-08f9edc89b4f Germany (DE)92b4386c-e5ab-444f-95be-43e1758d7166 France (FR)5e4ea114-26ff-402c-acb5-2e5fc34e10d1 Netherlands (NL)8cffde16-12dc-4fce-933f-374d54f4fa47 Spain (ES)6e68ca4c-fe07-4278-bd95-1afbb79714d2 Netherlands (NL)d930dbf9-748d-45b2-a1a8-47f2ccd1c44d Bulgaria (BG)5934e348-5f4f-4876-8065-3c684e919acd Sweden (SE)6e68ca4c-fe07-4278-bd95-1afbb79714d2 Netherlands (NL)3acd809e-c5d0-4f20-91c3-1f3d01b455b4 Poland (PL)f9e3242c-3f43-48ef-8ba4-46b6975a3fdd France (FR)c67644e0-dda8-4107-b8e9-978fdcebea28 Sweden (SE)11f8b80f-ea71-4297-a53f-4258d5d3b90f Germany (DE)1259445e-a1fd-4893-9b9f-08f9edc89b4f Germany (DE)92b4386c-e5ab-444f-95be-43e1758d7166 France (FR)5e4ea114-26ff-402c-acb5-2e5fc34e10d1 Netherlands (NL)8cffde16-12dc-4fce-933f-374d54f4fa47 Spain (ES)13d4e4b4-a0b7-4b0e-a670-bf1e01e9dc3d Poland (PL)383e131d-8ac9-464b-891c-edec40806df8 Norway (NO)4edfba22-9fdd-4b59-8ab8-17d5ad0e1490 Finland (FI)fa2a42d4-3bc2-4227-a0c8-cd97d76849db Netherlands (NL)ed0d7f17-8e19-4ea9-a0c0-ae7a50079494 Germany (DE)d5a17c63-7902-4635-832b-0cb8363bedac Denmark (DK)f0964070-7e0c-4541-9359-2d1975aa9945 Germany (DE)54f8c0e4-78d5-4efc-bb4a-e7bf97518408 Croatia (HR)7508a0e6-9533-4ab0-bfe5-bc229327607a Czech Republic (CZ)a9f952fd-daf0-4a35-9c2f-b2a31a011ae8 Poland (PL)18281490-6f95-4f80-a336-0e6b162be180 Netherlands (NL)d308258b-32b9-4087-bf09-6a66e3109ef4 Netherlands (NL)0a45d19b-4a2a-440f-af7c-53ac264325b3 Estonia (EE)fdd57062-d9fc-4bfd-9079-4a3a96ea94b1 Greece (GR)fb836575-46ef-4da4-9067-d404dc5946bb Portugal (PT)d930dbf9-748d-45b2-a1a8-47f2ccd1c44d Bulgaria (BG)5934e348-5f4f-4876-8065-3c684e919acd Sweden (SE)3acd809e-c5d0-4f20-91c3-1f3d01b455b4 Poland (PL)f9e3242c-3f43-48ef-8ba4-46b6975a3fdd France (FR)
Order Code US and Canada
XT1NE4080AFF000XXX
E-Number (Finland)
3640543
E-Number (Sweden)
3182421
EAN
8015644013172
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
101.6 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.4 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.466 kg
Package Level 1 EAN
8015644013172
Circuit Breaker Type to be Associated
Power Distribution
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour8000 cycle
Mechanical Durability
240 cycles per hour25000 cycle
Number of Poles
4
Opening Time
CB with SOR 15 msCB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 4.8 W
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Rated Current (In)
80 A
Rated Frequency (f)
50 / 60 Hz
Rated Voltage (Ur)
690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
800 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA(230 V AC) 50 kA(240 V AC) 50 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 18 kA(500 V AC) 15 kA(525 V AC) 11 kA(690 V AC) 5 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 22 kA(690 V AC) 6 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
Setting Range
56...80 A
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Version
F
ETIM 7
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Datasheet