Trade Price
£435.23
Per
1
Unit
EA
Pack Quantity
1
C.BREAKER TMAX XT1N 160 FIXED THREE-POLE WITH FRONT TERMINALS AND THERMOMAGNETIC RELEASE TMD R 160-1600 A
ABB EcoSolutions
Yes
Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 55.9 %
Group Waste to Landfill Target
UL 2799 Zero Waste To Landfill Validation available
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
0b280405-0d14-4a6b-8897-b8525b9a94f7 Italy (IT)
Simplified SCIP
67dff7ca-3c8d-47c8-95df-b0d8260514b6 Bulgaria (BG)07132179-5384-4118-9010-c83de9d8a1c4 Sweden (SE)b35ca2ed-077f-4c44-acd7-17ede1d32acb Poland (PL)3ff67411-b530-449f-9d7b-dbadc1806665 France (FR)b8684c66-06c8-4156-b9d3-c89dfb153bfd Norway (NO)79524225-1e57-4fbf-a42a-4b2bfd5a5b52 Finland (FI)452300e5-ac9f-4755-8e47-073c2a1686ae Netherlands (NL)7ac38085-6a69-483b-8b39-f252cbc23625 Germany (DE)222efe7b-e5af-453f-9429-9b3b9691646c Denmark (DK)9a610e0e-0a51-4297-88b0-f1f18655fbd2 Germany (DE)ee5bf16a-a048-4b18-adf7-65253667909a Croatia (HR)feaed771-e9e1-4cf2-97f3-45eb348f9b3e Czech Republic (CZ)4298cfc5-9a3d-4056-bb07-2e16a831dac5 Poland (PL)f075e8c8-1a9f-4a84-851a-63058e83f034 Netherlands (NL)fbe80637-1987-44f6-94a8-9f03837ddffe Netherlands (NL)50f42c46-845e-4213-bed8-55c751e75c4c Estonia (EE)3924bc4e-e052-4abc-a88f-14fe2173b008 Greece (GR)c62e9051-58eb-43b5-a3f7-c815a487c5cc Portugal (PT)50f42c46-845e-4213-bed8-55c751e75c4c Estonia (EE)3924bc4e-e052-4abc-a88f-14fe2173b008 Greece (GR)a6f175ab-18e9-471c-be5e-4afd197a0ddb Sweden (SE)4db124e2-aa86-45c7-becf-21d5d82affbc Germany (DE)00e27a3e-d89e-4d85-82dd-556b23ce8747 Germany (DE)e0d96579-9773-49a3-9e73-52f19b714a09 France (FR)65f2bfc2-55eb-459a-b585-b6f271e7084f Netherlands (NL)5e808fd3-830e-4f50-ae11-3751c6d40912 Spain (ES)ee34bc11-ba20-4a3f-91ef-63e6b955b5d2 Poland (PL)c62e9051-58eb-43b5-a3f7-c815a487c5cc Portugal (PT)a6f175ab-18e9-471c-be5e-4afd197a0ddb Sweden (SE)4db124e2-aa86-45c7-becf-21d5d82affbc Germany (DE)00e27a3e-d89e-4d85-82dd-556b23ce8747 Germany (DE)e0d96579-9773-49a3-9e73-52f19b714a09 France (FR)65f2bfc2-55eb-459a-b585-b6f271e7084f Netherlands (NL)5e808fd3-830e-4f50-ae11-3751c6d40912 Spain (ES)1d6cafc1-fed7-4e03-ad5b-1eb0a3ea51cc Netherlands (NL)67dff7ca-3c8d-47c8-95df-b0d8260514b6 Bulgaria (BG)07132179-5384-4118-9010-c83de9d8a1c4 Sweden (SE)1d6cafc1-fed7-4e03-ad5b-1eb0a3ea51cc Netherlands (NL)b35ca2ed-077f-4c44-acd7-17ede1d32acb Poland (PL)3ff67411-b530-449f-9d7b-dbadc1806665 France (FR)9a610e0e-0a51-4297-88b0-f1f18655fbd2 Germany (DE)ee5bf16a-a048-4b18-adf7-65253667909a Croatia (HR)feaed771-e9e1-4cf2-97f3-45eb348f9b3e Czech Republic (CZ)4298cfc5-9a3d-4056-bb07-2e16a831dac5 Poland (PL)f075e8c8-1a9f-4a84-851a-63058e83f034 Netherlands (NL)fbe80637-1987-44f6-94a8-9f03837ddffe Netherlands (NL)ee34bc11-ba20-4a3f-91ef-63e6b955b5d2 Poland (PL)b8684c66-06c8-4156-b9d3-c89dfb153bfd Norway (NO)79524225-1e57-4fbf-a42a-4b2bfd5a5b52 Finland (FI)452300e5-ac9f-4755-8e47-073c2a1686ae Netherlands (NL)7ac38085-6a69-483b-8b39-f252cbc23625 Germany (DE)222efe7b-e5af-453f-9429-9b3b9691646c Denmark (DK)
Order Code US and Canada
XT1NE3160AFF000XXX
E-Number (Finland)
3640521
E-Number (Sweden)
3182427
EAN
8015644013127
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
76.2 mm
Product Net Height
130 mm
Product Net Depth / Length
70 mm
Product Net Weight
1.1 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
128 mm
Package Level 1 Height
135 mm
Package Level 1 Depth / Length
143 mm
Package Level 1 Gross Weight
1.143 kg
Package Level 1 EAN
8015644013127
Circuit Breaker Type to be Associated
Power Distribution
Connecting Capacity Main Circuit
Busbar 45.5 ... 80 mm²
Current Type
AC/DC
Electrical Durability
120 cycles per hour8000 cycle
Mechanical Durability
240 cycles per hour25000 cycle
Number of Poles
3
Opening Time
CB with SOR 15 msCB with UVR 15 ms
Order Multiple
1 piece
Power Loss
at Rated Operating Conditions per Pole 15 W
Product Main Type
SACE Tmax XT
Product Name
Moulded Case Circuit Breaker
Product Type
Automatic Circuit Breaker
Rated Current (In)
160 A
Rated Frequency (f)
50 / 60 Hz
Rated Voltage (Ur)
690 V
Rated Impulse Withstand Voltage (Uimp)
8 kV
Rated Instantaneous Short-Circuit Current Setting (Ii)
1600 A
Rated Insulation Voltage (Ui)
800 V
Rated Operational Voltage
690 V AC500 V DC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 50 kA(230 V AC) 50 kA(240 V AC) 50 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 18 kA(500 V AC) 15 kA(525 V AC) 11 kA(690 V AC) 5 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 36 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(220 V AC) 65 kA(230 V AC) 65 kA(240 V AC) 65 kA(380 V AC) 36 kA(415 V AC) 36 kA(440 V AC) 36 kA(500 V AC) 30 kA(525 V AC) 22 kA(690 V AC) 6 kA(250 V DC) 2 Poles in Series 36 kA(500 V DC) 3 Poles in Series 36 kA
Rated Uninterrupted Current (Iu)
160 A
Recommended Screw Driver
Main Circuit M6
Release
TMD
Release Type
TM
RoHS Date
NA
Setting Range
112...160 A
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
XT1
Terminal Connection Type
Front
Terminal Type
Bolt
Tightening Torque
6 N·m
Version
F
ETIM 7
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
Object Classification Code
Q
UNSPSC
39120000
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409
Datasheet