This Acti9 iPRD surge arrester kit protects 1P+N installations. It allows quick replacement of damaged cartridges. This type 2 device is recommended for high risk level in incoming panel board. The iPRD ensures secondary protection of loads to be protected and is placed in cascade with the incoming surge arresters. This surge arrester is required when the loads to be protected are at a distance of more than 10 m from the incoming surge arrester. The associated circuit breaker Isc breaking capacity can go up to 15kA. This Acti9 iPRD is compatible with TT and TN-C earthing system. The Imax maximum discharge current is 20kA .The In nominal discharge current is 5kA. The Uc maximum continuous operating voltage in DM differential mode (between phase and neutral) is 350VAC. The Uc maximum continuous operating voltage in CM common mode (between earth and neutral) is 350VAC. The Up Voltage protection level in DM differential mode (between phase and neutral) is below or equal to 1.4kV. The Up Voltage protection level in CM common mode and in DM differential mode is below or equal to 1.4kV. The Ue rated operational voltage is 230VAC or 400VAC+/- 10%. The operating frequency is 50Hz. The product colour is light grey (RAL7035) in an enclosure. The dimensions are (W) 200mm x (H) 267mm x (D) 112mm. The degree of protection is IP65 in an weatherproof enclosure. The operating temperature is -35°C to +70°C. The storage temperature is -40°C to +80°C.
range of product
Acti9
Product or component type
Surge arrester kit
Device application
Distribution
Provided equipment
surge arrester iPRD20r 2P miniature circuit breaker (MCB) iC60H 2P neutral bar enclosure cable
Poles description
1P + N
Surge arrester type
Electrical distribution network
Surge arrester class type
Type 2
Surge arrester technology
MOV + GDT
Earthing system
TN-C TT
[Ue] rated operational voltage
230/400 V AC (+/- 10 %) at 50 Hz
Nominal discharge current
Common mode: 5 kA (L/PE) Common mode: 5 kA (N/PE) Differential mode: 5 kA (L/N)
Maximum discharge current
Common mode: 20 kA L/PE Common mode: 20 kA N/PE Differential mode: 20 kA L/N
[Uc] maximum continuous operating voltage
Common mode: 260 V L/PE Common mode: 350 V N/PE Differential mode: 350 V L/N
Maximum [Up] voltage protection level
Differential mode <1.4 kV type 2 L/N Common mode <1.4 kV type 2 N/PE
[Ut] temporary overvoltage
337 V L/N 5 s withstand 1200 V N/PE 200 ms safe failure mode 442 V L/PE 5 s withstand 1453 V L/PE 200 ms safe failure mode
Disconnector device type
Associated circuit breaker iC60H 20 A curve C - Icu 15 kA
Enclosure type
Mini enclosure for modular device
Enclosure mounting
Surface
type of front cover
Transparent
Type of rail
DIN
Locking options description
Optional keylock
Enclosure material
Self-extinguishing polymer
Height
Acti9 iC60: 85 mm Acti9 iPRD: 85 mm Kaedra enclosure: 267 mm
Width
Acti9 iC60: 36 mm Acti9 iPRD: 36 mm Kaedra enclosure: 200 mm
Depth
Acti9 iC60: 78.5 mm Acti9 iPRD: 69 mm Kaedra enclosure: 112 mm
Colour
Door: transparent green Enclosure: light grey (RAL 7035)
product certifications
CE
IP degree of protection
IP65 (weatherproof enclosure) conforming to IEC 60529
IK degree of protection
IK03 surge arrester conforming to IEC 62262 IK03 miniature circuit-breaker conforming to IEC 62262 IK09 weatherproof enclosure conforming to EN 50102
Relative humidity
95 % at 55 °C
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
21.0 cm
Package 1 Width
22.0 cm
Package 1 Length
26.5 cm
Package 1 Weight
1.562 kg
Unit Type of Package 2
P12
Number of Units in Package 2
64
Package 2 Height
112.0 cm
Package 2 Width
100.0 cm
Package 2 Length
120.0 cm
Package 2 Weight
107.6 kg
Warranty
18 months