1SFA896112R7000

PSR60-600-70 Softstarter (100-240V Sup (PSR60-600-70)

Trade Price

£651.18

Per

1

Unit

EA

Pack Quantity

1

1SFA896112R7000
1SFA896112R7000
1SFA896112R7000
1SFA896112R7000

Information

The softstarter PSR60-600-70 has a rated maximum operational current of 60 A with an operating voltage span from 208...600 V AC. The rated control voltage is between 100...240 V AC at 50/60 Hz. PSR features a two-phase control soft start and stop through a voltage ramp. It has built-in bypass for easy installation and energy saving. A RUN and a TOR signal is available from a relay output in NO (normally open state). The start/stop ramp and time is easy to set by three potentiometers on the front. PSR is often used in combination with a manual motor starter (MMS) from ABB, so mechanical connection kits are available. Another popular option is Fieldbus communication, which can be enabled by an external adaptor and a Fieldbus plug. The PSR range is our most compact softstarters with basic functionality and values. They are suitable for small three-phase motors with nominal currents from 3...105 A and can manage up to 100 starts per hour. Common applications are, for example, pumps, fans, compressors, and conveyors.

Technical Specifications

Minimum Order Quantity:

1 piece

Customs Tariff Number:

85371091

Product Net Width:

180 mm

Product Net Height:

220 mm

Product Net Depth / Length:

70 mm

Product Net Weight:

2.1 kg

Rated Operational Voltage:

208 ... 600 V AC

Rated Control Supply Voltage (Us):

100 ... 240 V AC

Rated Control Circuit Voltage (Uc):

24 V DC

Rated Frequency (f):

50/60 HzMain Circuit 50 / 60 Hz

Rated Operational Power - In-Line Connection (Pe):

(230 V) 15 kW(400 V) 30 kW(500 V) 37 kW

Rated Operational Current - In-Line Connection (Ie):

60 A

Service Factor Percentage:

100 %

Overload Protection:

Recommended MS495 45 ... 63

Integrated Electronic Overload:

No

Adjustable Rated Motor Current Ie:

No

Starting Capacity at Maximum Rated Current Ie:

4xIe for 6s

Ramp Time:

0 ... 20 second [unit of time]1 ... 10 second [unit of time]

Initial Voltage During Start:

40 ... 70 %

Step Down Voltage Special Ramp:

100 ... 60 %

Current Limit Function:

No

Switch for Inside Delta Connection:

No

Run Signal Relay:

Yes

By-pass Signal Relay:

Yes

Fault Signal Relay:

No

Overload Signal Relay:

No

Signal Indication Completed Start Ramp (LED):

Green

Signal Indication Ready to Start/Standby ON (LED):

Green

Signal Indication Running R (LED):

Green

Signal Indication Ramping Up/Down (LED):

Green

Number of Starts Per Hour at 3.5*Ie for 7 sec. 50% ON Time 50% OFF Time:

10

Communication:

FiledBusPlug(Optional)

Degree of Protection:

IP10

Terminal Type:

Main Circuit: Bars

Connecting Capacity Main Circuit:

Rigid 1x 10 ... 95 mm²Rigid 2 x 6 ... 35 mm²

Connecting Capacity Control Circuit:

1 x 0.75 ... 2.52 x 0.75 ... 2.5 mm²Rigid 1 x 0.75 ... 2.5 mm²Rigid 2 x 0.75 ... 1.5 mm²

Connecting Capacity Supply Circuit:

Rigid 1 x 0.75 ... 2.5 mm²

Tightening Torque:

Control Circuit 0.6 N·mMain Circuit 8 N·mSupply Circuit 0.6 N·m

Product Main Type:

PSR60

Function:

Soft start with voltage rampSoft stop with voltage ramp

Maximum Operating Voltage UL/CSA:

Main Circuit 600 V

Tightening Torque UL/CSA:

Control Circuit 5.3 in·lbMain Circuit 70.8Supply Circuit 5.3 in·lb

Ambient Air Temperature:

Operation -25 ... +60 °CStorage -40 ... +70 °C

RoHS Status:

Following EU Directive 2002/95/EC August 18, 2005 and amendment

Package Level 1 Width:

195 mm

Package Level 1 Depth / Length:

86 mm

Package Level 1 Height:

230 mm

Package Level 1 Gross Weight:

2.3 kg

Package Level 1 EAN:

7320500362594

Package Level 1 Units:

box 1 piece

Object Classification Code:

Q

ETIM 7:

EC000640 - Soft starter

ETIM 8:

EC000640 - Soft starter

ETIM 9:

EC000640 - Soft starter

eClass:

V11.0 : 27370907

UNSPSC:

39121521

IDEA Granular Category Code (IGCC):

4740 >> Soft starter

Document Links