1SBL367001R1400

AF52-30-00-14 250-500V50/60HZ-DC (AF52-30-00-14)

Trade Price

£196.10

Per

1

Unit

EA

Pack Quantity

1

1SBL367001R1400

Information

AF40...AF96 3 Pole contactors - 18.5 to 45kW AC/DC operated * Part number: AF52-30-00-14 * AF40 ... AF96 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening. * Built-in surge suppression * Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

55 mm

Product Net Depth / Length

111 mm

Product Net Height

125.5 mm

Product Net Weight

0.95 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

0

Number of Auxiliary Contacts NC

0

Standards

IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-1, UL 60947-4-1, CSA C22.2 No. 60947-1:22, CSA C22.2 No. 60947-4-1:22

Rated Operational Voltage

Main Circuit 690 V

Rated Frequency (f)

Control Circuit 50 / 60 HzMain Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 105 A

Rated Operational Current AC-1 (Ie)

(690 V) 40 °C 100 A(690 V) 60 °C 80 A(690 V) 70 °C 70 A

Rated Operational Current AC-3 (Ie)

(415 V) 60 °C 53 A(440 V) 60 °C 53 A(500 V) 60 °C 45 A(690 V) 60 °C 35 A(380 / 400 V) 60 °C 53 A(220 / 230 / 240 V) 60 °C 53 A

Rated Operational Current AC-3e (Ie)

(415 V) 60 °C 53 A(440 V) 60 °C 53 A(500 V) 60 °C 45 A(690 V) 60 °C 35 A(380 / 400 V) 60 °C 53 A(220 / 230 / 240 V) 60 °C 53 A

Rated Operational Power AC-3 (Pe)

(400 V) 22 kW(415 V) 30 kW(440 V) 30 kW(500 V) 30 kW(690 V) 30 kW(380 / 400 V) 22 kW(220 / 230 / 240 V) 15 kW

Rated Operational Power AC-3e (Pe)

(415 V) 30 kW(440 V) 30 kW(500 V) 30 kW(690 V) 30 kW(380 / 400 V) 22 kW(220 / 230 / 240 V) 15 kW

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 110 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 250 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 350 A

Maximum Breaking Capacity

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 950 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 600 A

Maximum Electrical Switching Frequency

(AC-1) 600 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 1200 cycles per hour

Rated Operational Current DC-1 (Ie)

(110 V) 2 Poles in Series, 40 °C 100 A(110 V) 2 Poles in Series, 60 °C 80 A(110 V) 2 Poles in Series, 70 °C 70 A(110 V) 3 Poles in Series, 40 °C 100 A(110 V) 3 Poles in Series, 60 °C 80 A(110 V) 3 Poles in Series, 70 °C 70 A(220 V) 3 Poles in Series, 40 °C 100 A(220 V) 3 Poles in Series, 60 °C 80 A(220 V) 3 Poles in Series, 70 °C 70 A(72 V) 1-Pole, 40 °C 100 A(72 V) 1-Pole, 60 °C 80 A(72 V) 1-Pole, 70 °C 70 A(72 V) 2 Poles in Series, 40 °C 100 A(72 V) 2 Poles in Series, 60 °C 80 A(72 V) 2 Poles in Series, 70 °C 70 A(72 V) 3 Poles in Series, 40 °C 100 A(72 V) 3 Poles in Series, 60 °C 80 A(72 V) 3 Poles in Series, 70 °C 70 A

Rated Operational Current DC-3 (Ie)

(110 V) 2 Poles in Series, 40 °C 100 A(110 V) 2 Poles in Series, 60 °C 80 A(110 V) 2 Poles in Series, 70 °C 70 A(110 V) 3 Poles in Series, 40 °C 100 A(110 V) 3 Poles in Series, 60 °C 80 A(110 V) 3 Poles in Series, 70 °C 70 A(220 V) 3 Poles in Series, 40 °C 100 A(220 V) 3 Poles in Series, 60 °C 80 A(220 V) 3 Poles in Series, 70 °C 70 A(72 V) 1-Pole, 40 °C 100 A(72 V) 1-Pole, 60 °C 80 A(72 V) 1-Pole, 70 °C 70 A(72 V) 2 Poles in Series, 40 °C 100 A(72 V) 2 Poles in Series, 60 °C 80 A(72 V) 2 Poles in Series, 70 °C 70 A(72 V) 3 Poles in Series, 40 °C 100 A(72 V) 3 Poles in Series, 60 °C 80 A(72 V) 3 Poles in Series, 70 °C 70 A

Rated Operational Current DC-5 (Ie)

(110 V) 2 Poles in Series, 40 °C 100 A(110 V) 2 Poles in Series, 60 °C 80 A(110 V) 2 Poles in Series, 70 °C 70 A(110 V) 3 Poles in Series, 40 °C 100 A(110 V) 3 Poles in Series, 60 °C 80 A(110 V) 3 Poles in Series, 70 °C 70 A(220 V) 3 Poles in Series, 40 °C 100 A(220 V) 3 Poles in Series, 60 °C 80 A(220 V) 3 Poles in Series, 70 °C 70 A(72 V) 1-Pole, 40 °C 100 A(72 V) 1-Pole, 60 °C 80 A(72 V) 1-Pole, 70 °C 70 A(72 V) 2 Poles in Series, 40 °C 100 A(72 V) 2 Poles in Series, 60 °C 80 A(72 V) 2 Poles in Series, 70 °C 70 A(72 V) 3 Poles in Series, 40 °C 100 A(72 V) 3 Poles in Series, 60 °C 80 A(72 V) 3 Poles in Series, 70 °C 70 A

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 690 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

6 kV

Maximum Mechanical Switching Frequency

3600 cycles per hour

Rated Control Circuit Voltage (Uc)

50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V

Coil Consumption

Average Holding Value 50 / 60 Hz 4 V·AAverage Holding Value 50 Hz 4 V·AAverage Holding Value 60 Hz 4 V·AAverage Holding Value DC 2 WAverage Holding Value, from Warm State 2 W

Operate Time

Between Coil De-energization and NC Contact Closing 19 ... 105 msBetween Coil De-energization and NO Contact Opening 17 ... 100 msBetween Coil Energization and NC Contact Opening 38 ... 95 msBetween Coil Energization and NO Contact Closing 42 ... 100 ms

Mounting on DIN Rail

TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715

Mounting by Screws (not supplied)

2 x M4 or 2 x M6 screws placed diagonally

Connecting Capacity Main Circuit

Flexible with Ferrule 1/2x 4 ... 35 mm²Flexible with Insulated Ferrule 1/2x 4 ... 35 mm²Rigid Stranded 1/2x 6 ... 35 mm²

Connecting Capacity Control Circuit

Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²

Wire Stripping Length

Control Circuit 10 mmMain Circuit 16 mm

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP10

Terminal Type

Screw Terminals

Maximum Operating Voltage UL/CSA

Main Circuit 600 V

General Use Rating UL/CSA

(600 V AC) 80 A

Horsepower Rating UL/CSA

(120 V AC) Single Phase 3 hp(200 ... 208 V AC) Three Phase 15 hp(220 ... 240 V AC) Three Phase 20 hp(240 V AC) Single Phase 10 hp(440 ... 480 V AC) Three Phase 40 hp(550 ... 600 V AC) Three Phase 50 hp

Connecting Capacity Main Circuit UL/CSA

Rigid Stranded 1/2x 10-2 AWG

Connecting Capacity Control Circuit UL/CSA

Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG

Tightening Torque UL/CSA

Control Circuit 11 in·lbMain Circuit 35 in·lb

Ambient Air Temperature

Close to Contactor Fitted with Thermal O/L Relay -40 ... 70 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C

Climatic Withstand

Category B according to IEC 60947-1 Annex Q

Maximum Operating Altitude Permissible

Without Derating 3000 m

Resistance to Shock acc. to IEC 60068-2-27

Closed, Shock Direction: A 25 gClosed, Shock Direction: B1 25 gClosed, Shock Direction: B2 15 gClosed, Shock Direction: C1 25 gClosed, Shock Direction: C2 25 gOpen, Shock Direction: B1 5 g

Resistance to Vibrations acc. to IEC 60068-2-6

5 ... 300 Hz 3 g closed position / 3 g open position

RoHS Status

Following EU Directive 2011/65/EU

Package Level 1 Units

box 1 piece

Package Level 1 Width

150 mm

Package Level 1 Depth / Length

150 mm

Package Level 1 Height

97 mm

Package Level 1 Gross Weight

1.05 kg

Package Level 1 EAN

3471523132344

Package Level 2 Units

box 10 piece

Package Level 2 Width

250 mm

Package Level 2 Depth / Length

300 mm

Package Level 2 Height

300 mm

Package Level 2 Gross Weight

10.5 kg

Package Level 3 Units

240 piece

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3707017

E-Number (Sweden)

3210040

Document Links