1SFL677001R7011

AF1650-30-11 100-250V AC/DC Contactor (AF1650-30-11)

Trade Price

£8,830.97

Per

1

Unit

EA

Pack Quantity

1

1SFL677001R7011

Information

AF1250...AF2650 3 Pole contactor * Part number: AF1650-30-11 * AF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC, AF2650 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request). * Built-in surge suppression * Add-on auxiliary contact blocks for side mounting and a wide range of accessories

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

438 mm

Product Net Depth / Length

244 mm

Product Net Height

392 mm

Product Net Weight

33 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

1

Number of Auxiliary Contacts NC

1

Rated Operational Voltage

Main Circuit 1000 V

Rated Frequency (f)

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1650 A

Rated Operational Current AC-1 (Ie)

(1000 V) 40 °C 1650 A(1000 V) 55 °C 1450 A(1000 V) 70 °C 1270 A(690 V) 40 °C 1650 A(690 V) 55 °C 1450 A(690 V) 70 °C 1270 A

Rated Operational Current AC-3 (Ie)

(415 V) 55 °C 1060 A(440 V) 55 °C 1060 A(500 V) 55 °C 970 A(690 V) 55 °C 970 A(1000 V) 55 °C 400 A(380 / 400 V) 55 °C 1060 A(220 / 230 / 240 V) 55 °C 1060

Rated Operational Power AC-3 (Pe)

(415 V) 630 kW(440 V) 710 kW(500 V) 710 kW(690 V) 1000 kW(1000 V) 600 kW(380 / 400 V) 560 kW(220 / 230 / 240 V) 315 kW

Rated Making Capacity AC-3

10 x Ie AC-3

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 10000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 2200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 5500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 12000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 7500 A

Maximum Breaking Capacity

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 12000 A

Maximum Electrical Switching Frequency

(AC-1) 60 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 60 cycles per hour

Rated Operational Current DC-1 (Ie)

(110 V) 1-Pole, 40 °C 1650 A(110 V) 2 Poles in Series, 40 °C 1650 A(220 V) 3 Poles in Series, 40 °C 1650 A(600 V) 3 Poles in Series, 40 °C 1650 A(850 V) 3 Poles in Series, 40 °C 1650 A

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 1000 V

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Mechanical Durability

0.5 million

Maximum Mechanical Switching Frequency

300 cycles per hour

Coil Operating Limits

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)

Rated Control Circuit Voltage (Uc)

50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V

Coil Consumption

Holding at Max. Rated Control Circuit Voltage 50 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 48 V·AHolding at Max. Rated Control Circuit Voltage DC 20.5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 2450 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 2450 V·APull-in at Max. Rated Control Circuit Voltage DC 2290 V·A

Operate Time

Between Coil De-energization and NC Contact Closing 35 ... 55 msBetween Coil De-energization and NO Contact Opening 35 ... 55 msBetween Coil Energization and NC Contact Opening 50 ... 80 msBetween Coil Energization and NO Contact Closing 50 ... 80 ms

Connecting Capacity Main Circuit

Bar 100 mm²

Connecting Capacity Auxiliary Circuit

Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type

Main Circuit: Bars

NEMA Size

8

Horsepower Rating NEMA

(230 V AC) Three Phase 450 Hp(460 V AC) Three Phase 900 Hp(575 V AC) Three Phase 900 Hp

Maximum Operating Voltage UL/CSA

Main Circuit 1000 V

General Use Rating UL/CSA

(1000 V AC) 1650 A(600 V AC) 1650 A

Horsepower Rating UL/CSA

(220 ... 240 V AC) Three Phase 450 hp(440 ... 480 V AC) Three Phase 900 hp(550 ... 600 V AC) Three Phase 1150 hp

Ambient Air Temperature

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C

Maximum Operating Altitude Permissible

Without Derating 3000 m

RoHS Status

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Package Level 1 Units

box 1 piece

Package Level 1 Width

555 mm

Package Level 1 Depth / Length

365 mm

Package Level 1 Height

500 mm

Package Level 1 Gross Weight

35 kg

Package Level 1 EAN

7320500249703

Package Level 2 Units

1 piece

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3709258

E-Number (Norway)

4115390

E-Number (Sweden)

4115390

Document Links