1SFL647001R7011

AF1250-30-11 100-250V 50/60Hz Contactor (AF1250-30-11)

Trade Price

£4,770.45

Per

1

Unit

EA

Pack Quantity

1

1SFL647001R7011

Information

AF1250...AF2650 3 Pole contactor * Part number: AF1250-30-11 * AF1250 ... AF2050 contactors are mainly used for controlling power circuits up to 1000 V AC or 850 V DC, AF2650 for controlling power up to 1000 V AC. These contactors are of the block type design with 3 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request). * Built-in surge suppression * Add-on auxiliary contact blocks for side mounting and a wide range of accessories

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

210 mm

Product Net Depth / Length

242 mm

Product Net Height

344 mm

Product Net Weight

14.6 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

1

Number of Auxiliary Contacts NC

1

Rated Operational Voltage

Main Circuit 1000 V

Rated Frequency (f)

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 1050 A

Rated Operational Current AC-1 (Ie)

(1000 V) 40 °C 1260 A(1000 V) 55 °C 1040 A(1000 V) 70 °C 875 A(690 V) 40 °C 1260 A(690 V) 55 °C 1040 A(690 V) 70 °C 875 A

Rated Breaking Capacity AC-3

8 x Ie AC-3

Rated Making Capacity AC-3

10 x Ie AC-3

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 7200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 1500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 4000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 8000 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 5200 A

Maximum Breaking Capacity

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 7500 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 7000 A

Maximum Electrical Switching Frequency

(AC-1) 300 cycles per hour

Rated Operational Current DC-1 (Ie)

(220 V) 3 Poles in Series, 40 °C 1250 A(600 V) 3 Poles in Series, 40 °C 1250 A(850 V) 3 Poles in Series, 40 °C 1250 A

Rated Operational Current DC-3 (Ie)

(220 V) 3 Poles in Series, 40 °C 1250 A(600 V) 3 Poles in Series, 40 °C 1250 A(850 V) 3 Poles in Series, 40 °C 1250 A

Rated Operational Current DC-5 (Ie)

(220 V) 3 Poles in Series, 40 °C 1250 A(600 V) 3 Poles in Series, 40 °C 1250 A(850 V) 3 Poles in Series, 40 °C 1250 A

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Mechanical Durability

0.5 million

Maximum Mechanical Switching Frequency

300 cycles per hour

Coil Operating Limits

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)

Rated Control Circuit Voltage (Uc)

50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V

Coil Consumption

Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 880 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 880 V·APull-in at Max. Rated Control Circuit Voltage DC 880 V·A

Operate Time

Between Coil De-energization and NC Contact Closing 50 ... 70 msBetween Coil De-energization and NO Contact Opening 53 ... 73 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms

Connecting Capacity Main Circuit

Bar 50 mm²

Connecting Capacity Auxiliary Circuit

Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm²

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Connecting Terminals (delivered in open position) Main Poles

M 3.5 (+,-) pozidriv 2 screw with cable clamp

Terminal Type

Main Circuit: Bars

Horsepower Rating NEMA

(230 V AC) Three Phase 300 Hp(460 V AC) Three Phase 600 Hp(575 V AC) Three Phase 600 Hp

Maximum Operating Voltage UL/CSA

Main Circuit 1000 V

General Use Rating UL/CSA

(1000 V AC) 1210 A

Ambient Air Temperature

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C

Maximum Operating Altitude Permissible

Without Derating 3000 m

Resistance to Shock acc. to IEC 60068-2-27

Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g

RoHS Status

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

Package Level 1 Units

box 1 piece

Package Level 1 Width

280 mm

Package Level 1 Depth / Length

375 mm

Package Level 1 Height

310 mm

Package Level 1 Gross Weight

16 kg

Package Level 1 EAN

7320500355091

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3709324

E-Number (Norway)

4115382

E-Number (Sweden)

4115382