Trade Price
£2,411.70
Per
1
Unit
EA
Pack Quantity
1
AF400...AF750 3 Pole contactor * Part number: AF460-30-11 * AF400 ... AF750 contactors are mainly used for controlling 3-phase motors and power circuits up to 1000 V AC or 600 V DC. These contactors are of the block type design with 3 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltages sags (SEMI F47 conditions of use on request). * Built-in surge suppression * Add-on auxiliary contact blocks for side mounting and a wide range of accessories * AF400 ... AF750 are equipped with low voltage inputs for control, for example by a PLC.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Product Net Width
186 mm
Product Net Depth / Length
216 mm
Product Net Height
278 mm
Product Net Weight
10.6 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
1
Number of Auxiliary Contacts NC
1
Rated Operational Voltage
Main Circuit 1000 V
Rated Frequency (f)
Main Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 700 A
Rated Operational Current AC-1 (Ie)
(1000 V) 40 °C 700 A(1000 V) 55 °C 600 A(1000 V) 60 °C 600 A(1000 V) 70 °C 480 A(690 V) 40 °C 700 A(690 V) 55 °C 600 A(690 V) 70 °C 480 A
Rated Operational Current AC-3 (Ie)
(415 V) 55 °C 460 A(440 V) 55 °C 460 A(500 V) 55 °C 460 A(690 V) 55 °C 400 A(1000 V) 55 °C 200 A(380 / 400 V) 55 °C 460 A(220 / 230 / 240 V) 55 °C 460
Rated Operational Power AC-3 (Pe)
(415 V) 250 kW(440 V) 250 kW(500 V) 315 kW(690 V) 355 kW(1000 V) 280 kW(380 / 400 V) 250 kW(220 / 230 / 240 V) 132 kW
Rated Breaking Capacity AC-3
8 x Ie AC-3
Rated Making Capacity AC-3
10 x Ie AC-3
Short-Circuit Protective Devices
gG Type Fuses 800 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 4400 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 840 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 2500 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 4600 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 3100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 5000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 4500 A
Maximum Electrical Switching Frequency
(AC-1) 300 cycles per hour(AC-2 / AC-4) 60 cycles per hour(AC-3) 300 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 700 A(110 V) 2 Poles in Series, 40 °C 700 A(220 V) 3 Poles in Series, 40 °C 700 A(600 V) 3 Poles in Series, 40 °C 700 A
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
Main Circuit 8 kV
Mechanical Durability
3 million
Maximum Mechanical Switching Frequency
300 cycles per hour
Coil Operating Limits
(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)
Rated Control Circuit Voltage (Uc)
DC Operation 24 ... 60 V
Coil Consumption
Holding at Max. Rated Control Circuit Voltage 50 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 12 V·AHolding at Max. Rated Control Circuit Voltage DC 5 V·APull-in at Max. Rated Control Circuit Voltage 50 Hz 900 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 900 V·APull-in at Max. Rated Control Circuit Voltage DC 900 V·A
Operate Time
Between Coil De-energization and NC Contact Closing 45 ... 55 msBetween Coil De-energization and NO Contact Opening 48 ... 58 msBetween Coil Energization and NC Contact Opening 45 ... 115 msBetween Coil Energization and NO Contact Closing 50 ... 120 ms
Connecting Capacity Main Circuit
Bar 47 mm²Rigid Al-Cable 2x240 mm²Rigid Cu-Cable 240 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 1x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 2 x 1 .... 4 mm²
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00
Terminal Type
Main Circuit: Bars
NEMA Size
6
Horsepower Rating NEMA
(200 V AC) Three Phase 150 Hp(230 V AC) Three Phase 200 Hp(460 V AC) Three Phase 400 Hp(575 V AC) Three Phase 400 Hp
Maximum Operating Voltage UL/CSA
Main Circuit 1000 V
General Use Rating UL/CSA
(600 V AC) 650 A
Horsepower Rating UL/CSA
(200 V AC) Three Phase 150 hp(208 V AC) Three Phase 150 hp(220 ... 240 V AC) Three Phase 200 hp(440 ... 480 V AC) Three Phase 400 hp(550 ... 600 V AC) Three Phase 500 hp
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Shock Direction: A 5 gShock Direction: B1 5 gShock Direction: B2 5 gShock Direction: C1 5 gShock Direction: C2 5 g
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
ABB EcoSolutions
Yes
Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 63.1 %
Group Waste to Landfill Target
Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility
Improved Resource Efficiency for Customers
Product Efficiency - Product considered more energy-efficient compared to similar product on market or older products from the same line
Sustainable Material Content
Recycled Metal - 37 %
Package Level 1 Units
box 1 piece
Package Level 1 Width
280 mm
Package Level 1 Depth / Length
375 mm
Package Level 1 Height
310 mm
Package Level 1 Gross Weight
12 kg
Package Level 1 EAN
7320500217887
Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
ETIM 6
EC000066 - Power contactor, AC switching
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Norway)
4115290
E-Number (Sweden)
3228342