1SFL467001R1311

AF146-30-11-13 100-250V50/60HZ-DC (AF146-30-11-13)

Trade Price

£695.19

Per

1

Unit

EA

Pack Quantity

1

1SFL467001R1311

Information

AF116...AF146 3 Pole contactors - 55 to 200kW AC/DC operated 1NO+1NC aux * Part number: AF146-30-11-13 * AF116.AF140 contactors are mainly used for controlling 3-phase motors and power circuits up to 690V AC. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 coils to cover control voltages between 24...500 V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening - can withstand short voltage dips and voltage sags (SEMI F47 conditions of use on request). * Built-in surge suppression * Add-on auxiliary contact blocks for side mounting and a wide range of accessories

Technical Specifications

Minimum Order Quantity

1 piece

Customs Tariff Number

85364900

Product Net Width

90 mm

Product Net Depth / Length

126 mm

Product Net Height

150 mm

Product Net Weight

1.55 kg

Number of Main Contacts NO

3

Number of Main Contacts NC

0

Number of Auxiliary Contacts NO

1

Number of Auxiliary Contacts NC

1

Rated Operational Voltage

Main Circuit 1000 V

Rated Frequency (f)

Main Circuit 50 / 60 Hz

Conventional Free-air Thermal Current (Ith)

acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 225 A

Rated Operational Current AC-1 (Ie)

(1000 V) 40 °C 225 A(1000 V) 55 °C 200 A(1000 V) 60 °C 200 A(1000 V) 70 °C 175 A(690 V) 40 °C 225 A(690 V) 55 °C 200 A(690 V) 60 °C 200 A(690 V) 70 °C 175 A

Rated Operational Current AC-3 (Ie)

(415 V) 55 °C 146 A(440 V) 55 °C 146 A(500 V) 55 °C 130 A(690 V) 55 °C 93 A(1000 V) 55 °C 60 A(380 / 400 V) 55 °C 146 A(220 / 230 / 240 V) 55 °C 146

Rated Operational Current AC-3e (Ie)

(415 V) 60 °C 146 A(440 V) 60 °C 146 A(500 V) 60 °C 130 A(690 V) 60 °C 93 A(1000 V) 60 °C 54 A(380 / 400 V) 60 °C 146 A(220 / 230 / 240 V) 60 °C 146 A

Rated Operational Power AC-3 (Pe)

(415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW

Rated Operational Power AC-3e (Pe)

(415 V) 75 kW(440 V) 90 kW(500 V) 90 kW(690 V) 90 kW(1000 V) 75 kW(380 / 400 V) 75 kW(220 / 230 / 240 V) 45 kW

Rated Breaking Capacity AC-3

8 x Ie AC-3

Rated Breaking Capacity AC-3e

8.5 x Ie AC-3e

Rated Making Capacity AC-3

10 x Ie AC-3

Rated Making Capacity AC-3e

12 x Ie AC-3e

Short-Circuit Protective Devices

gG Type Fuses 315 A

Rated Short-time Withstand Current Low Voltage (Icw)

at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 1168 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 200 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 477 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 1460 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 674 A

Maximum Breaking Capacity

cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 3000 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 1500 A

Maximum Electrical Switching Frequency

(AC-1) 300 cycles per hour(AC-2 / AC-4) 150 cycles per hour(AC-3) 300 cycles per hour

Rated Insulation Voltage (Ui)

acc. to IEC 60947-4-1 and VDE 0110 (Gr. C) 1000 Vacc. to UL/CSA 600 V

Rated Impulse Withstand Voltage (Uimp)

Main Circuit 8 kV

Mechanical Durability

5 million

Maximum Mechanical Switching Frequency

300 cycles per hour

Coil Operating Limits

(acc. to IEC 60947-4-1) 0.85 x Uc Min. ... 1.1 x Uc Max. (at θ <= 70 °C)

Rated Control Circuit Voltage (Uc)

50 Hz 100 ... 250 V60 Hz 100 ... 250 VDC Operation 100 ... 250 V

Coil Consumption

Holding at Max. Rated Control Circuit Voltage 50 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage 60 Hz 6 V·AHolding at Max. Rated Control Circuit Voltage DC 3 WPull-in at Max. Rated Control Circuit Voltage 50 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage 60 Hz 130 V·APull-in at Max. Rated Control Circuit Voltage DC 135 W

Operate Time

Between Coil De-energization and NO Contact Opening 37 ... 47 msBetween Coil Energization and NO Contact Closing 25 ... 55 ms

Connecting Capacity Main Circuit

Flexible 1 x 10 ... 70 mm²Rigid Cu-Cable 1 x 10 ... 95 mm²

Connecting Capacity Auxiliary Circuit

Flexible with Ferrule 2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Flexible 2x0.75 ... 2.5 mm²Solid 2 x 1 ... 4 mm²Stranded 1 x 1 .... 4 mm²

Degree of Protection

acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP00

Terminal Type

Double Clamp

Maximum Operating Voltage UL/CSA

Main Circuit 1000 V

General Use Rating UL/CSA

(600 V AC) 200 A

Horsepower Rating UL/CSA

(200 V AC) Three Phase 40 hp(208 V AC) Three Phase 40 hp(220 ... 240 V AC) Three Phase 50 hp(440 ... 480 V AC) Three Phase 100 hp(550 ... 600 V AC) Three Phase 125 hp

Ambient Air Temperature

Close to Contactor Fitted with Thermal O/L Relay (0.85 ... 1.1 Uc) -25 ... 50 °CClose to Contactor without Thermal O/L Relay (0.85 ... 1.1 Uc) -40 ... 70 °CClose to Contactor for Storage -40 ... 70 °C

Maximum Operating Altitude Permissible

Without Derating 3000 m

RoHS Status

Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019

ABB EcoSolutions

Yes

Circular Design Principles Recyclability Rate

Design for Closing Resource Loops - Standard EN45555 - 87.8 %

Group Waste to Landfill Target

Non-hazardous waste is sent to a landfill, where there is no alternative option available within 100km of a facility

Improved Resource Efficiency for Customers

Product Efficiency - Product requires less energy to operate compared to similar product on market or older products from the same line

Sustainable Material Content

Recycled Metal - 37 %

Package Level 1 Units

box 1 piece

Package Level 1 Width

207 mm

Package Level 1 Depth / Length

216 mm

Package Level 1 Height

150 mm

Package Level 1 Gross Weight

1.75 kg

Package Level 1 EAN

7320500476994

Object Classification Code

Q

ETIM 4

EC000066 - Magnet contactor, AC-switching

ETIM 5

EC000066 - Magnet contactor, AC-switching

ETIM 6

EC000066 - Power contactor, AC switching

ETIM 7

EC000066 - Power contactor, AC switching

ETIM 8

EC000066 - Power contactor, AC switching

eClass

V11.0 : 27371003

UNSPSC

39121529

IDEA Granular Category Code (IGCC)

4758 >> Iec Contactors

E-Number (Finland)

3706370

E-Number (Norway)

4117629

Document Links