Trade Price
£62.16
Per
1
Unit
EA
Pack Quantity
1
AF09...AF38 3 pole contactors - 4 to 18.5kW AC/DC operated * Part number: AF16-30-01-14 * AF09 ... AF38 contactors are mainly used for controlling 3-phase motors and power circuits up to 690 V AC and 220 V DC. These contactors are of the block type design with 3 main poles. * Control circuit: AC or DC operated with electronic coil interface accepting a wide control voltage range (e.g. 100...250 V AC and DC), only 4 control voltage ranges covering 24...500V 50/60 Hz and 20...500 V DC - can manage large control voltage variations - reduced panel energy consumption - very distinct closing and opening. * Built-in surge suppression * Add-on auxiliary contact blocks for front or side mounting and a wide range of accessories.
Minimum Order Quantity
1 piece
Customs Tariff Number
85364900
Product Net Width
45 mm
Product Net Depth / Length
77 mm
Product Net Height
86 mm
Product Net Weight
0.31 kg
Number of Main Contacts NO
3
Number of Main Contacts NC
0
Number of Auxiliary Contacts NO
0
Number of Auxiliary Contacts NC
1
Standards
IEC/EN 60947-1, IEC/EN 60947-4-1, UL 60947-4-1, CSA C22.2 No. 60947-4-1
Rated Operational Voltage
Auxiliary Circuit 690 VMain Circuit 690 V
Rated Frequency (f)
Auxiliary Circuit 50 / 60 HzControl Circuit 50 / 60 HzMain Circuit 50 / 60 Hz
Conventional Free-air Thermal Current (Ith)
acc. to IEC 60947-4-1, Open Contactors Θ = 40 °C 35 Aacc. to IEC 60947-5-1, Θ = 40 °C 16 A
Rated Operational Current AC-1 (Ie)
(690 V) 40 °C 30 A(690 V) 60 °C 30 A(690 V) 70 °C 26 A
Rated Operational Current AC-3 (Ie)
(415 V) 60 °C 18 A(440 V) 60 °C 18 A(500 V) 60 °C 15 A(690 V) 60 °C 10.5 A(380 / 400 V) 60 °C 18 A(220 / 230 / 240 V) 60 °C 18 A
Rated Operational Current AC-3e (Ie)
(415 V) 60 °C 18 A(440 V) 60 °C 18 A(500 V) 60 °C 15 A(690 V) 60 °C 10.5 A(380 / 400 V) 60 °C 18 A(220 / 230 / 240 V) 60 °C 18 A
Rated Operational Power AC-3 (Pe)
(400 V) 7.5 kW(415 V) 9 kW(440 V) 9 kW(500 V) 9 kW(690 V) 9 kW(380 / 400 V) 7.5 kW(220 / 230 / 240 V) 4 kW
Rated Operational Power AC-3e (Pe)
(415 V) 9 kW(440 V) 9 kW(500 V) 9 kW(690 V) 9 kW(380 / 400 V) 7.5 kW(220 / 230 / 240 V) 4 kW
Rated Operational Current AC-15 (Ie)
(500 V) 2 A(690 V) 2 A(24 / 127 V) 6 A(220 / 240 V) 4 A(400 / 440 V) 3 A
Rated Short-time Withstand Current Low Voltage (Icw)
at 40 °C Ambient Temp, in Free Air, from a Cold State 10 s 150 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 15 min 35 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 min 60 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 1 s 300 Aat 40 °C Ambient Temp, in Free Air, from a Cold State 30 s 80 Afor 0.1 s 140 Afor 1 s 100 A
Maximum Breaking Capacity
cos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 440 V 250 Acos phi=0.45 (cos phi=0.35 for Ie > 100 A) at 690 V 106 A
Maximum Electrical Switching Frequency
(AC-1) 600 cycles per hour(AC-15) 1200 cycles per hour(AC-2 / AC-4) 300 cycles per hour(AC-3) 1200 cycles per hour(DC-13) 900 cycles per hour
Rated Operational Current DC-1 (Ie)
(110 V) 1-Pole, 40 °C 20 A(110 V) 1-Pole, 60 °C 20 A(110 V) 1-Pole, 70 °C 20 A(110 V) 2 Poles in Series, 40 °C 30 A(110 V) 2 Poles in Series, 60 °C 30 A(110 V) 2 Poles in Series, 70 °C 26 A(110 V) 3 Poles in Series, 40 °C 30 A(110 V) 3 Poles in Series, 60 °C 30 A(110 V) 3 Poles in Series, 70 °C 26 A(220 V) 2 Poles in Series, 40 °C 20 A(220 V) 2 Poles in Series, 60 °C 20 A(220 V) 2 Poles in Series, 70 °C 20 A(220 V) 3 Poles in Series, 40 °C 30 A(220 V) 3 Poles in Series, 60 °C 30 A(220 V) 3 Poles in Series, 70 °C 26 A(72 V) 1-Pole, 40 °C 30 A(72 V) 1-Pole, 60 °C 30 A(72 V) 1-Pole, 70 °C 26 A(72 V) 2 Poles in Series, 40 °C 30 A(72 V) 2 Poles in Series, 60 °C 30 A(72 V) 2 Poles in Series, 70 °C 26 A(72 V) 3 Poles in Series, 40 °C 30 A(72 V) 3 Poles in Series, 60 °C 30 A(72 V) 3 Poles in Series, 70 °C 26 A
Rated Operational Current DC-3 (Ie)
(110 V) 1-Pole, 40 °C 8 A(110 V) 1-Pole, 60 °C 8 A(110 V) 1-Pole, 70 °C 8 A(110 V) 2 Poles in Series, 40 °C 30 A(110 V) 2 Poles in Series, 60 °C 30 A(110 V) 2 Poles in Series, 70 °C 26 A(110 V) 3 Poles in Series, 40 °C 30 A(110 V) 3 Poles in Series, 60 °C 30 A(110 V) 3 Poles in Series, 70 °C 26 A(220 V) 2 Poles in Series, 40 °C 8 A(220 V) 2 Poles in Series, 60 °C 8 A(220 V) 2 Poles in Series, 70 °C 8 A(220 V) 3 Poles in Series, 40 °C 30 A(220 V) 3 Poles in Series, 60 °C 30 A(220 V) 3 Poles in Series, 70 °C 26 A(72 V) 1-Pole, 40 °C 30 A(72 V) 1-Pole, 60 °C 30 A(72 V) 1-Pole, 70 °C 26 A(72 V) 2 Poles in Series, 40 °C 30 A(72 V) 2 Poles in Series, 60 °C 30 A(72 V) 2 Poles in Series, 70 °C 26 A(72 V) 3 Poles in Series, 40 °C 30 A(72 V) 3 Poles in Series, 60 °C 30 A(72 V) 3 Poles in Series, 70 °C 26 A
Rated Operational Current DC-5 (Ie)
(110 V) 1-Pole, 40 °C 4 A(110 V) 1-Pole, 60 °C 4 A(110 V) 1-Pole, 70 °C 4 A(110 V) 2 Poles in Series, 40 °C 20 A(110 V) 2 Poles in Series, 60 °C 20 A(110 V) 2 Poles in Series, 70 °C 20 A(110 V) 3 Poles in Series, 40 °C 30 A(110 V) 3 Poles in Series, 60 °C 30 A(110 V) 3 Poles in Series, 70 °C 26 A(220 V) 2 Poles in Series, 40 °C 4 A(220 V) 2 Poles in Series, 60 °C 4 A(220 V) 2 Poles in Series, 70 °C 4 A(220 V) 3 Poles in Series, 40 °C 16 A(220 V) 3 Poles in Series, 60 °C 16 A(220 V) 3 Poles in Series, 70 °C 16 A(72 V) 1-Pole, 40 °C 16 A(72 V) 1-Pole, 60 °C 16 A(72 V) 1-Pole, 70 °C 16 A(72 V) 2 Poles in Series, 40 °C 30 A(72 V) 2 Poles in Series, 60 °C 30 A(72 V) 2 Poles in Series, 70 °C 26 A(72 V) 3 Poles in Series, 40 °C 30 A(72 V) 3 Poles in Series, 60 °C 30 A(72 V) 3 Poles in Series, 70 °C 26 A
Rated Operational Current DC-13 (Ie)
(24 V) 6 A / 144 W(48 V) 2.8 A / 134 W(72 V) 1 A / 72 W(110 V) 0.55 A / 60 W(125 V) 0.55 A / 69 W(220 V) 0.27 A / 60 W(250 V) 0.27 A / 68 W(400 V) 0.15 A / 60 W(500 V) 0.13 A / 65 W(600 V) 0.1 A / 60 W
Rated Insulation Voltage (Ui)
acc. to IEC 60947-4-1 690 Vacc. to IEC 60947-5-1 690 Vacc. to UL/CSA 600 V
Rated Impulse Withstand Voltage (Uimp)
6 kV
Maximum Mechanical Switching Frequency
3600 cycles per hour
Rated Control Circuit Voltage (Uc)
50 Hz 250 ... 500 V60 Hz 250 ... 500 VDC Operation 250 ... 500 V
Operate Time
Between Coil De-energization and NC Contact Closing 13 ... 98 msBetween Coil De-energization and NO Contact Opening 11 ... 95 msBetween Coil Energization and NC Contact Opening 38 ... 90 msBetween Coil Energization and NO Contact Closing 40 ... 95 ms
Mounting on DIN Rail
TH35-15 (35 x 15 mm Mounting Rail) acc. to IEC 60715TH35-7.5 (35 x 7.5 mm Mounting Rail) acc. to IEC 60715
Mounting by Screws (not supplied)
2 x M4 screws placed diagonally
Connecting Capacity Main Circuit
Flexible with Ferrule 1/2x 0.75 ... 6 mm²Flexible with Insulated Ferrule 1x 0.75 ... 4 mm²Flexible with Insulated Ferrule 2x 0.75 ... 2.5 mm²Rigid Solid 1/2x 1 ... 4 mm²Rigid Stranded 1/2x 1 ... 6 mm²
Connecting Capacity Auxiliary Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Connecting Capacity Control Circuit
Flexible with Ferrule 1/2x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 1x 0.75 ... 2.5 mm²Flexible with Insulated Ferrule 2x 0.75 ... 1.5 mm²Rigid Solid 1/2x 1 ... 2.5 mm²Rigid Stranded 1/2x 1 ... 2.5 mm²
Wire Stripping Length
Auxiliary Circuit 10 mmControl Circuit 10 mmMain Circuit 10 mm
Degree of Protection
acc. to IEC 60529, IEC 60947-1, EN 60529 Auxiliary Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Coil Terminals IP20acc. to IEC 60529, IEC 60947-1, EN 60529 Main Terminals IP20
Terminal Type
Screw Terminals
Maximum Operating Voltage UL/CSA
Main Circuit 600 V
General Use Rating UL/CSA
(600 V AC) 30 A
Horsepower Rating UL/CSA
(120 V AC) Single Phase 1-1/2 hp(200 ... 208 V AC) Three Phase 5 hp(220 ... 240 V AC) Three Phase 5 hp(240 V AC) Single Phase 3 hp(440 ... 480 V AC) Three Phase 10 hp(550 ... 600 V AC) Three Phase 15 hp
Connecting Capacity Main Circuit UL/CSA
Rigid Solid 1/2x 16-10 AWGRigid Stranded 1/2x 16-10 AWG
Connecting Capacity Auxiliary Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Connecting Capacity Control Circuit UL/CSA
Rigid Solid 1/2x 18-14 AWGRigid Stranded 1/2x 18-14 AWG
Tightening Torque UL/CSA
Auxiliary Circuit 11 in·lbControl Circuit 11 in·lbMain Circuit 13 in·lb
Ambient Air Temperature
Close to Contactor Fitted with Thermal O/L Relay -25 ... 60 °CClose to Contactor without Thermal O/L Relay -40 ... 70 °CClose to Contactor for Storage -60 ... +80 °C
Climatic Withstand
Category B according to IEC 60947-1 Annex Q
Maximum Operating Altitude Permissible
Without Derating 3000 m
Resistance to Shock acc. to IEC 60068-2-27
Closed, Shock Direction: B1 25 gOpen, Shock Direction: B1 5 gShock Direction: A 30 gShock Direction: B2 15 gShock Direction: C1 25 gShock Direction: C2 25 g
Resistance to Vibrations acc. to IEC 60068-2-6
5 ... 300 Hz 4 g closed position / 2 g open position
RoHS Status
Following EU Directive 2011/65/EU
Package Level 1 Units
box 1 piece
Package Level 1 Width
87 mm
Package Level 1 Depth / Length
79 mm
Package Level 1 Height
47 mm
Package Level 1 Gross Weight
0.31 kg
Package Level 1 EAN
3471523110748
Package Level 2 Units
box 27 piece
Package Level 2 Width
250 mm
Package Level 2 Depth / Length
300 mm
Package Level 2 Height
315 mm
Package Level 2 Gross Weight
8.37 kg
Package Level 3 Units
1296 piece
Object Classification Code
Q
ETIM 4
EC000066 - Magnet contactor, AC-switching
ETIM 5
EC000066 - Magnet contactor, AC-switching
ETIM 6
EC000066 - Power contactor, AC switching
ETIM 7
EC000066 - Power contactor, AC switching
ETIM 8
EC000066 - Power contactor, AC switching
eClass
V11.0 : 27371003
UNSPSC
39121529
IDEA Granular Category Code (IGCC)
4758 >> Iec Contactors
E-Number (Finland)
3706247
E-Number (Sweden)
3211375