Trade Price
£172.84
Per
1
Unit
EA
Pack Quantity
1
This device is a panel mount or flush mount power meter with a 96mm by 96mm bezel size having backlit LCD display of 128 by 128 pixels. The meter measures active energy as per accuracy class Class 1.0 complying to IEC 62053-21 standard with sampling rate of 64 samples per cycle. Able to measures all three vectors of power and energy such as Active, Apparent & Reactive beside Voltages, Current, Frequency and Power Factor. Plus the total Harmonic Distortion and Individual harmonics up to 15th Harmonic order. The meter will function in either 50Hz or 60Hz network frequency and accepts universal control power voltages ranging from 44 to 300 V Line to Neutral AC or DC voltages. Rated current for this meter is either 1A or 5A input. it supports up to 13 different types of wiring schemes under Single Phase, Two Phase or Three Phase configuration types. The range of measurement voltage between Phases is 35 to 480 V Line to Line AC at 45 to 65 Hz while it is 20 to 277 V between Line and Neutral. It is having RS485 communication port over Modbus RTU protocol. Product dimensions are as follows: width 3.78 in (96 mm), depth 2.16 in (54 mm), height 3.78 in (96 mm) and product weight 10.58 oz (300 g).
Range
EasyLogic
Product name
EasyLogic PM2200
Device short name
PM2220
Product or component type
Power meter
Device application
Power monitoring Sub billing
Power quality analysis
total harmonic distortion up to the 15th harmonic
Type of measurement
Apparent power min/max, total Active and reactive power min/max, total Current min/max, avg Voltage min/max, avg Frequency min/max, avg Total current harmonic distortion THD (I) per phase Total voltage harmonic distortion THD (U) per phase Power factor min/max, avg Apparent energy total Active and reactive energy total
Metering type
Active, reactive, apparent energy (signed, four quadrant) Current I, I1, I2, I3 Peak demand currents Peak demand power PM, QM, SM Unbalance current Active power P, P1, P2, P3 Reactive power Q, Q1, Q2, Q3 Demand power P, Q, S Voltage U, U21, U32, U13, V, V1, V2, V3 Apparent power S, S1, S2, S3 Calculated neutral current
Accuracy class
Class 1 active energy conforming to IEC 62053-21 Class 1 reactive energy conforming to IEC 62053-24 Class 5 harmonic distorsion (I THD & U THD)
Measurement accuracy
Apparent power +/- 1 % Active energy +/- 1 % Reactive energy +/- 1 % Active power +/- 1 % Voltage +/- 0.5 % Power factor +/- 0.01 Current +/- 0.5 % Frequency +/- 0.05 %
Measurement current
5…6000 mA
Measurement voltage
35…480 V AC 50/60 Hz between phases 20…277 V AC 50/60 Hz between phase and neutral 480…999000 V AC 50/60 Hz with external VT
Frequency measurement range
45…65 Hz
[Us] rated supply voltage
44...277 V AC 45...65 Hz +/- 10 % 44...277 V DC +/- 10 %
Network frequency
50 Hz 60 Hz
Ride-through time
100 ms 120 V AC typical 400 ms 230 V AC typical 50 ms 125 V DC typical
[In] rated current
1 A 5 A
Maximum power consumption in VA
6 VA at 277 V AC
Maximum power consumption in W
3.3 W (power lines (AC)) 2 W at 277 V (power lines (DC))
input impedance
Current (impedance <= 0.3 mOhm) Voltage (impedance > 5 MOhm)
Tamperproof of settings
Protected by access code
Display type
Backlit LCD
Display colour
Monochrome
Display resolution
128 x 128 pixels
Demand intervals
Configurable from 1 to 60 min
Information displayed
Demand current (past value) Demand current (present value) Demand power (past value) Demand power (present value) Voltage Current Frequency Energy consumption Harmonic distortion Power factor Active power Apparent power Reactive power Unbalanced in % Harmonic amplitude
Control type
4 x button
Local signalling
Red LED: output signal 1...9999000 pulse/ k_h (kWh, kVAh, kVARh) Green LED: module operation and integrated communication
Number of inputs
0
Number of outputs
0
Communication port protocol
Modbus RTU at 4800 bps, 9600 bps, 19200 bps, 38.4 Kbps even/odd or none - 2 wires, insulation 2500 V
Communication port support
Screw terminal block: RS485
data recording
Time stamping Min/max for 8 parameters
Function available
Real time clock
Sampling rate
64 samples/cycle
Cybersecurity
Enable/disable communication ports
Communication service
Remote monitoring
User language
Spanish French English Russian Portuguese German Chinese
Product certifications
CE conforming to IEC 61010-1 CULus conforming to UL 61010-1 CULus conforming to CSA C22.2 No 61010-1 RCM EAC C-Tick
Mounting mode
Clip-on
Mounting position
Vertical
Mounting support
Framework
Provided equipment
1 x installation guide
Measurement category
Category III 480 V Category II 480…600 V
Electrical insulation class
Double insulation Class II
Flame retardance
V-0 conforming to UL 94
Connections - terminals
Current transformer: screw connection (bottom) 6 Voltage inputs: screw connection (top) 4
Material
Polycarbonate
Width
96 mm
Depth
76.09 mm total: 61.64 mm embedded:
height
96 mm
Net weight
300 g
Compatibility code
PM2220
Service life
7 year(s)
IP degree of protection
IP54 front: conforming to IEC 60529 IP30 body: conforming to IEC 60529
Relative humidity
5…95 % at 50 °C
Pollution degree
2
Ambient air temperature for operation
-10…60 °C
Ambient air temperature for storage
-25…70 °C
Operating altitude
<= 2000 m
Electromagnetic compatibility
Electrostatic discharge conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test conforming to IEC 61000-4-4 Surge immunity test conforming to IEC 61000-4-5 Conducted RF disturbances conforming to IEC 61000-4-6 Magnetic field at power frequency conforming to IEC 61000-4-8 Voltage dips and interruptions immunity test conforming to IEC 61000-4-11 Emission tests conforming to FCC part 15 class A
Overvoltage category
III
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.9 cm
Package 1 Width
12.2 cm
Package 1 Length
11.7 cm
Package 1 Weight
270 g
Warranty
18 months
Datasheet