ETR4-11-A

Timer, on-delayed, 24-240V AC/DC

Trade Price

£108.91

Per

1

Unit

EACH

Pack Quantity

1

ETR4-11-A

Information

Eaton Moeller® series ETR4 Timing relay, 1W, 0.05s-100h, 24-240V50/60Hz, 24-240VDC, on-delayed

Technical Specifications

Product Length/Depth

103 mm

Product Height

82 mm

Product Width

23 mm

Product Weight

0.109 kg

Certifications

UL File No.: E29184

Standard IEC/EN 61812

CSA

CSA-22.2 No. 14

UL

VDE 0435

CE

CSA Class No.: 3211-03

UL Category Control No.: NKCR

CSA File No.: 012528

IEC/EN 61000-4-2

UL 508

IEC/EN 60947-5-1

IEC/EN 61000-4-3

IEC/EN 61812-1

Electric connection type

Screw connection

Functions

Fixed timing function

On-delayed

Delay-on energization

Degree of protection

Terminals: IP20

IP20

Lifespan, mechanical

30,000,000 Operations (DC operated)

30,000,000 Operations (AC operated)

Mounting position

As required

Number of contacts (change-over contacts)

1

Overvoltage category

III

Pollution degree

2

Product category

ETR4 timing relays

Rated impulse withstand voltage (Uimp)

6000 V AC

4000 V AC

Shock resistance

4 g, Make contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 20 ms

Suitable for

DIN rail (top hat rail) mounting

Terminal capacity

2 x (0.5 - 1.5) mm², flexible with ferrule

1 x (20 - 14) AWG, solid or stranded

2 x (0.5 - 1.5) mm², solid

1 x (0.5 - 2.5) mm², solid

1 x (0.5 - 2.5) mm², flexible with ferrule

Time range - min

0.05 s

Time range - max

360000 s

Type

Timer relay

Voltage type

AC/DC

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

60 °C

Ambient operating temperature (enclosed) - min

25 °C

Ambient operating temperature (enclosed) - max

45 °C

Ambient storage temperature - min

45 °C

Ambient storage temperature - max

85 °C

Climatic proofing

Damp heat, constant, to IEC 60068-2-78

Damp heat, cyclic, to IEC 60068-2-30

Air discharge

8 kV

Burst impulse

1 kV, Signal cable

According to IEC/EN 61000-4-4

2 kV, Supply cable

Contact discharge

6 kV

Electromagnetic fields

10 V/m at 80 - 1000 MHz (according to IEC EN 61000-4-3)

1 V/m at 2.0 - 2.7 GHz (according to IEC EN 61000-4-3)

3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)

Immunity to line-conducted interference

10 V (according to IEC/EN 61000-4-6)

Radio interference class

Class B (EN 55011, conducted)

Class B (EN 55011, radiated)

Surge rating

4 kV, asymmetrical, power pulses (Surge), EMC

According to IEC/EN 61000-4-5, power pulses (Surge), EMC

2 kV, symmetrical, power pulses (Surge), EMC

Conventional thermal current ith of auxiliary contacts (1-pole, open)

6 A

Mains voltage tolerance

24 - 240 V AC (at 50/60 Hz)

24 – 240 V DC

Nominal current

3 A

Rated breaking capacity

3 A at AC-14 (cos ϕ = 0.3 440 V)

1.1 x Iₑ (DC-11 L/R - 40 ms)

3 A at AC-15 (cos ϕ = 0.3 220 V)

Rated frequency - min

47 Hz

Rated frequency - max

63 Hz

Rated making capacity

1.1 x Iₑ (DC-11 L/R - 40 ms)

50 A (AC-15 cos ϕ = 0.3 220 V)

48 A (AC-14 cos ϕ = 0.3 400 V)

Rated operational current (Ie)

3 A at AC-14, 440 V

3 A at AC-14, 380 V 400 V 415 V

1.5 A at DC-11, 24 V

3 A at AC-15, 380 V 400 V 415 V

1.2 A at DC-11, L/R max. 50 ms

3 A at AC-15, 300 V

3 A at AC-15, 220 V 230 V 240 V

3 A at AC-14, 300 V (NC)

Rated operational voltage (Ue) at AC - min

24 V

Rated operational voltage (Ue) at AC - max

440 V

Rated operational voltage (Ue) at DC - min

24 V

Rated operational voltage (Ue) at DC - max

240 V

Safe isolation

250 V AC, Between auxiliary contacts, According to EN 61140

250 V AC, Between coil and auxiliary contacts, According to EN 61140

Short-circuit protection rating

Max. 6 A gG/gL, Fuse, Short-circuit rating without welding, Contacts

Max. 6 A gG/gL, fuse, Without welding, Contacts

Command time

50 ms, AC

30 ms, DC

Contact changeover time

4 ms

Duty factor

100 %

Operating frequency

4000 Operations/h

Pick-up voltage

0.85 - 1.1 V AC x Uc

0.7 - 1.1 V DC x Uc

Power consumption

2 VA at AC (Sealing power)

2 VA at AC (Pick-up power)

1.8 W at DC (Sealing power)

1.8 W at DC (Pick-up power)

Rated control supply voltage (Us) at AC, 50 Hz - min

24 V

Rated control supply voltage (Us) at AC, 50 Hz - max

240 V

Rated control supply voltage (Us) at AC, 60 Hz - min

24 V

Rated control supply voltage (Us) at AC, 60 Hz - max

240 V

Rated control supply voltage (Us) at DC - min

24 V

Rated control supply voltage (Us) at DC - max

240 V

Recovery time

70 ms (after 100 % time delay)

Repetition accuracy

<= 0.5 % (deviation)

Voltage tolerance

0.85 x Uc, AC operated min.

1.1 x Uc, DC operated max.

0.7 x Uc, DC operated min.

1.1 x Uc, AC operated max.

Equipment heat dissipation, current-dependent Pvid

0 W

Heat dissipation capacity Pdiss

0 W

Heat dissipation per pole, current-dependent Pvid

1.4 W

Rated operational current for specified heat dissipation (In)

6 A

Static heat dissipation, non-current-dependent Pvs

1.8 W

10.2.2 Corrosion resistance

Meets the product standard's requirements.

10.2.3.1 Verification of thermal stability of enclosures

Meets the product standard's requirements.

10.2.3.2 Verification of resistance of insulating materials to normal heat

Meets the product standard's requirements.

10.2.3.3 Resist. of insul. mat. to abnormal heat/fire by internal elect. effects

Meets the product standard's requirements.

10.2.4 Resistance to ultra-violet (UV) radiation

Meets the product standard's requirements.

10.2.5 Lifting

Does not apply, since the entire switchgear needs to be evaluated.

10.2.6 Mechanical impact

Does not apply, since the entire switchgear needs to be evaluated.

10.2.7 Inscriptions

Meets the product standard's requirements.

10.3 Degree of protection of assemblies

Does not apply, since the entire switchgear needs to be evaluated.

10.4 Clearances and creepage distances

Meets the product standard's requirements.

10.5 Protection against electric shock

Does not apply, since the entire switchgear needs to be evaluated.

10.6 Incorporation of switching devices and components

Does not apply, since the entire switchgear needs to be evaluated.

10.7 Internal electrical circuits and connections

Is the panel builder's responsibility.

10.8 Connections for external conductors

Is the panel builder's responsibility.

10.9.2 Power-frequency electric strength

Is the panel builder's responsibility.

10.9.3 Impulse withstand voltage

Is the panel builder's responsibility.

10.9.4 Testing of enclosures made of insulating material

Is the panel builder's responsibility.

10.10 Temperature rise

The panel builder is responsible for the temperature rise calculation. Eaton will provide heat dissipation data for the devices.

10.11 Short-circuit rating

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.12 Electromagnetic compatibility

Is the panel builder's responsibility. The specifications for the switchgear must be observed.

10.13 Mechanical function

The device meets the requirements, provided the information in the instruction leaflet (IL) is observed.

Document Links

Datasheet