Trade Price
£194.92
Per
1
Unit
EACH
Pack Quantity
1
Eaton Moeller series xEffect - FAZ MCB. Miniature circuit breaker (MCB), 10 A, 3p+N, characteristic: K
Product Length/Depth
80 mm
Product Height
75.5 mm
Product Width
72 mm
Product Weight
0.423 kg
Compliances
RoHS conform
Certifications
IEC/EN 60947-2
IEC/EN 60898
EN45545-2
IEC 61373
Rated operational current for specified heat dissipation (In)
10 A
Rated short-circuit breaking capacity (EN 60898) at 230 V
0 kA
Mounting Method
Top-hat rail IEC/EN 60715
Current limiting class
3
Rated short-circuit breaking capacity (EN 60898) at 400 V
0 kA
Amperage Rating
10 A
Terminal capacity of screw terminals for main cable
10 mm² (2x)
Frequency rating - max
60 Hz
Rated short-circuit breaking capacity (IEC 60947-2) at 400 V
10 kA
Number of poles (total)
4
Terminal protection
Finger and hand touch safe, DGUV VS3, EN 50274
Rated short-circuit breaking capacity (IEC 60947-2) at 230 V
10 kA
Special features
Ambient temperature hint: a 1 °C increase results in a 0.5% linear reduction of current carrying capacity
Ambient operating temperature - max
75 °C
Heat dissipation per pole, current-dependent
0 W
Built-in depth
70.5 mm
Features
Concurrently switching N-neutral
Additional equipment possible
Lifespan, electrical
10000 operations
Connectable conductor cross section (solid-core) - min
1 mm²
Number of poles
Three-pole + N
Ambient operating temperature - min
-25 °C
Selectivity class
3
Terminal capacity (control cable)
25 mm² (1x)
Used with
FAZ
Miniature circuit breaker
Mounting position
As required
Equipment heat dissipation, current-dependent
5.3 W
Tripping characteristic
K
Frequency rating - min
50 Hz
Static heat dissipation, non-current-dependent
0 W
Application
Switchgear for industrial and advanced commercial applications
xEffect - Switchgear for industrial and advanced commercial applications
Voltage type
AC
Number of poles (protected)
3
Frame
45 mm
Terminals (top and bottom)
Twin-purpose terminals
Heat dissipation capacity
0 W
Release characteristic
K
Width in number of modular spacings
4
Busbar material thickness
0.8 mm - 2 mm
Power loss
5.3 W
Enclosure width
80 mm
Voltage rating
240 V AC / 415 V AC
Connectable conductor cross section (solid-core) - max
25 mm²
Degree of protection
IP40 (when fitted)
IP20
Overvoltage category
III
Pollution degree
2
Connectable conductor cross section (multi-wired) - min
1 mm²
Rated impulse withstand voltage (Uimp)
4 kV
Voltage rating at DC
60 V DC (per pole)
Admissible back-up fuse - max
125 A gL/gG
Rated switching capacity (IEC/EN 60947-2)
10 kA
Connectable conductor cross section (multi-wired) - max
25 mm²
Mounting width per pole
17.5 mm
Type
FAZ
Miniature circuit breaker
Operational switching capacity
7.5 kA
Direction of incoming supply
As required
Rated operational voltage (Ue) - max
400 V
Mounting width
17.5 mm
Rated insulation voltage (Ui)
440 V
Datasheet