FAZ-D8/3

MCB, 8A, D-type, TP, 15kA

Trade Price

£99.75

Per

1

Unit

EACH

Pack Quantity

1

FAZ-D8/3
FAZ-D8/3
FAZ-D8/3
FAZ-D8/3

Information

Eaton Moeller series xEffect - FAZ MCB. FAZ, 3-pole, tripping characteristic: D, rated current In: 8 A

Technical Specifications

Product Length/Depth

80 mm

Product Height

75.5 mm

Product Width

54 mm

Product Weight

0.333 kg

Warranty

1 year

Compliances

UL CSA09 (with supplementary protector only)

RoHS conform

Certifications

UL 1077

CSA (File No. 204453)

UL (Category Control Number QVNU2, QVNU8)

CE marking

UL (File No. E177451)

North America (UL recognized, CSA certified)

IEC/EN 60898

IEC/EN 60947-2

CSA-C22.2 No. 235

CSA (Class No. 3215-30)

EN45545-2

IEC 61373

Catalog Notes

Magnetic range for higher startup inrush levels that are usually seen in motors and transformers, and other high inductive systems.

Application

Branch circuits, not as BCPD

Switchgear for industrial and advanced commercial applications

xEffect - Switchgear for industrial and advanced commercial applications

Number of poles

Three-pole

Number of poles (total)

3

Number of poles (protected)

3

Tripping characteristic

D

Release characteristic

D

Amperage Rating

8 A

Type

FAZ

Miniature circuit breaker

Voltage type

AC

Voltage rating

240 V AC / 415 V AC

Voltage rating at DC

60 V DC (per pole)

Voltage rating (UL CSA 13)

480 Y/277 V AC

Rated operational voltage (Ue) - max

400 V

Rated insulation voltage (Ui)

440 V

Rated impulse withstand voltage (Uimp)

4 kV

Frequency rating - min

50 Hz

Frequency rating - max

60 Hz

Rated switching capacity (IEC/EN 60947-2)

15 kA

Operational switching capacity

7.5 kA

Rated short-circuit breaking capacity (EN 60898) at 230 V

10 kA

Rated short-circuit breaking capacity (EN 60898) at 400 V

10 kA

Rated short-circuit breaking capacity (IEC 60947-2) at 230 V

15 kA

Rated short-circuit breaking capacity (IEC 60947-2) at 400 V

15 kA

Admissible back-up fuse - max

125 A gL/gG

Selectivity class

3

Overvoltage category

III

Pollution degree

2

Lifespan, electrical

10000 operations

Direction of incoming supply

As required

Frame

45 mm

Enclosure width

80 mm

Width in number of modular spacings

3

Built-in depth

70.5 mm

Mounting width per pole

17.5 mm

Mounting width

17.5 mm

Mounting Method

Top-hat rail IEC/EN 60715

Mounting position

As required

Degree of protection

IP20 (IEC)

IP20

IP40 (when fitted)

UL/CSA Type: -

Terminals (top and bottom)

Twin-purpose terminals

Connectable conductor cross section (solid-core) - min

1 mm²

Connectable conductor cross section (solid-core) - max

25 mm²

Connectable conductor cross section (multi-wired) - min

1 mm²

Connectable conductor cross section (multi-wired) - max

25 mm²

Terminal capacity of screw terminals for main cable

10 mm² (2x)

Terminal capacity (control cable)

25 mm² (1x)

Terminal protection

Finger and hand touch safe, DGUV VS3, EN 50274

Busbar material thickness

0.8 mm - 2 mm

Rated operational current for specified heat dissipation (In)

8 A

Equipment heat dissipation, current-dependent

4 W

Ambient operating temperature - min

-25 °C

Ambient operating temperature - max

75 °C

Current limiting class

3

Features

Additional equipment possible

Used with

FAZ

Miniature circuit breaker

Document Links

Datasheet