Trade Price
£9,009.64
Per
1
Unit
EA
Pack Quantity
1
C.BREAKER SACE EMAX2 E2.2N 1250 FIXED THREE-POLE WITH TERMINALS REAR HORIZONTAL AND SOLID-STATE RELEASE IN AC EKIP/HI-TOUCH-LSIG R 1250 FITTED WITH: 4 AUXILIARY CONTACT AND C.BREAKER IN POSITION OPEN-CLOSED
ABB EcoSolutions
Yes
Circular Design Principles Recyclability Rate
Design for Closing Resource Loops - Standard EN45555 - 79.1 %
Group Waste to Landfill Target
UL 2799 Zero Waste To Landfill Validation available
RoHS Status
Following EU Directive 2011/65/EU and Amendment 2015/863 July 22, 2019
SCIP
dbba8de8-e106-464e-9f7a-70e1c52d73e8 Italy (IT)
Simplified SCIP
07b2ee6d-9669-48f2-81cb-7096d374a22f Finland (FI)e2ad3f74-e732-49ae-924f-de25de5667ce Greece (GR)913a7bdc-abb0-4868-b764-e2c4478df87e Poland (PL)c78e0d7b-9b07-4a76-b11f-90394d04a8b0 Poland (PL)50f75dab-6e56-4334-a09d-f71f465f8d84 Portugal (PT)e7db332f-d8d9-4961-8d2b-f868098c88a1 Sweden (SE)40d8706c-b2ff-4906-aed2-3b2c6342d505 Hungary (HU)de42216d-1174-4e90-850b-187aa7e153ad Belgium (BE)d975d8fe-3465-4b4a-90c4-36eb53195c74 Spain (ES)5cff99fb-8282-4cc3-85e7-7c2e12077868 Bulgaria (BG)7d0796b3-23d2-4227-8367-4ed5dc9049b7 France (FR)1323d27d-b94a-4844-819a-6a0fc4241ad6 Croatia (HR)4f4a91d6-cf17-48a1-8d11-1b767d85d409 Hungary (HU)81cb16d3-b575-498a-8950-e58a1d30f17f Norway (NO)c4b9fbbe-b1a1-4005-8a2e-2a2e0fbc60a2 Poland (PL)5863bdce-65f0-46ab-bbe3-a55ee310aa03 Czech Republic (CZ)faba19e6-285a-4f36-b3ca-ec5ca0de5b98 Denmark (DK)97279c38-73bf-46c4-b7a3-c4e760f6e2a7 Estonia (EE)3b415c89-d3cb-421c-ad9f-2d086c97adb0 Germany (DE)3fb1a001-1405-4954-8413-cab41f6633fc Germany (DE)6c3497ce-0d18-41a5-a99e-17673c3900a2 Germany (DE)1ef18321-c03c-4252-8bc2-dd7541c07d92 Germany (DE)1ea37df1-ebc2-4bb3-9b49-40f9749c09d0 Belgium (BE)f100e551-2c6f-496a-89d5-eba4656323da Sweden (SE)c4572356-6e9b-468e-8684-27ead26e969c Netherlands (NL)64c37c6a-d24b-4dd1-8836-2ff6d99bb685 France (FR)
Order Code US and Canada
Z2NREHBK200A000000XX
EAN
8015644748098
Minimum Order Quantity
1 piece
Customs Tariff Number
85362090
Product Net Width
276 mm
Product Net Height
371 mm
Product Net Depth / Length
270 mm
Product Net Weight
41 kg
Package Level 1 Units
box 1 piece
Package Level 1 Width
515 mm
Package Level 1 Height
610 mm
Package Level 1 Depth / Length
515 mm
Package Level 1 Gross Weight
46 kg
Package Level 1 EAN
8015644748098
Current Type
AC
Electrical Durability
Ue =< 440 V 15000 cycleUe = 500 ... 690 V 15000 cycle30 cycles per hour
Mechanical Durability
25000 cycle60 cycles per hour
Number of Poles
3
Power Loss
83 W
Product Main Type
SACE Emax 2
Product Name
Air Circuit Breaker
Product Type
Air Circuit Breaker
Rated Service Short-Circuit Breaking Capacity, in % of Icu (Ics)
100 %
Rated Current (In)
1250 A
Rated Voltage (Ur)
690 V
Rated Impulse Withstand Voltage (Uimp)
acc. to IEC 60947-2 12 kV
Rated Insulation Voltage (Ui)
AC 1000 V
Rated Operational Voltage
690 V AC
Rated Service Short-Circuit Breaking Capacity (Ics)
(220 V AC) 66 kA(230 V AC) 66 kA(380 V AC) 66 kA(400 V AC) 66 kA(415 V AC) 66 kA(440 V AC) 66 kA(500 V AC) 66 kA(660 V AC) 66 kA(690 V AC) 66 kA
Rated Short-time Withstand Current Low Voltage (Icw)
for 1 s 66 kAfor 3 s 50 kA
Rated Ultimate Short-Circuit Breaking Capacity (Icu)
(400 V AC) 66 kA(415 V AC) 66 kA(440 V AC) 66 kA(500 V AC) 66 kA(525 V AC) 66 kA(690 V AC) 66 kA
Rated Uninterrupted Current (Iu)
1250 A
Recommended Screw Driver
Main Circuit M12
Release
Ekip Hi-Touch LSIG
Release Type
EL
Short-Circuit Performance Level
N
Standards
IEC
Sub-type
E2.2
Terminal Connection Type
Rear flat Horizontal
Terminal Type
Bolt
Tightening Torque
70 N·m
Version
F
ETIM 7
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 8
EC000228 - Power circuit-breaker for trafo/generator/installation protection
ETIM 9
EC000228 - Power circuit-breaker for trafo/generator/installation protection
IDEA Granular Category Code (IGCC)
4926 >> Air circuit breakers
Object Classification Code
Q
UNSPSC
39121615
WEEE Category
5. Small Equipment (No External Dimension More Than 50 cm)
eClass
V11.1 : 27370409