It is a remote controlled source changeover system for Compact NSX, Compact NS and Masterpact devices. It is composed of an ACP plate and of an automatic UA controller. This ACP provides in a single unit the protection of the controller, the control and the connection to the devices. The UA controller is used to create a source-changeover transfer from one source to another depending on the presence of voltage UN on the “Normal” source. UA controller integrates also the start up of an engine generator set, the shedding and reconnection of non-priority circuits, the transfer to the “Replacement” source if one of the phases on the “Normal” source fails. The control voltage is from 220VAC to 240VAC 50/60Hz.
Range of product
NSX100...250 Compact NS100...630 MasterPact NW MasterPact NT NSX400...630 Compact NS630b...1600
Product or component type
Interface and control unit
accessory / separate part category
Interlocking accessory
Range compatibility
ComPact (ComPact NS) circuit breaker ComPact (ComPact NSX) circuit breaker Masterpact (MasterPact NT) circuit breaker Masterpact (MasterPact NW) circuit breaker
Device short name
ACP + UA
[Us] rated supply voltage
220...240 V AC at 50/60 Hz
Operating mode
Automatic operation Forced operation on normal source Stop (both normal and replacement source off) Forced operation on replacement source
Interlocked device
MasterPact NT NSX400...630 MasterPact NW NSX100...250 Compact NS100...630 Compact NS630b...1600
Selection modes
Circuit breaker on R Circuit breaker on N
Test function
By pressing the test button on the front of the controller
Complementary function
Voluntary transfer to replacement source (e.g. energy management commands) Forced normal source if replacement source not operational during peak-tariff Selection of type of normal source (single-phase or three-phase) Setting of maximum startup time for the replacement source Additional contact: transfer to replacement source only if contact is closed
Local signalling
On Off Fault trip
Input type
Contacts customer voluntary order to transfer to source R
Output type
Contacts customer: indication of operation in automatic or stop mode
[Ith] conventional free air thermal current
8 A
[Ie] rated operational current
AC-12: 4 A AC 440 V AC-12: 5 A AC 380/415 V AC-12: 8 A AC 110 V AC-12: 8 A AC 220/240 V AC-12: 8 A AC 24 V AC-12: 8 A AC 48 V AC-13: 6 A AC 110 V AC-13: 6 A AC 220/240 V AC-13: 7 A AC 24 V AC-13: 7 A AC 48 V AC-14: 4 A AC 110 V AC-14: 4 A AC 220/240 V AC-14: 5 A AC 24 V AC-14: 5 A AC 48 V AC-15: 3 A AC 220/240 V AC-15: 4 A AC 110 V AC-15: 5 A AC 24 V AC-15: 5 A AC 48 V DC-12: 0.4 A DC 250 V DC-12: 0.6 A DC 110 V DC-12: 2 A DC 48 V DC-12: 8 A DC 24 V DC-13: 2 A AC 24 V
Product compatibility
Compact NS630b...1600 Compact NSX100...250 Compact NSX400...630
standards
IEC 947-5-1
IP degree of protection
IP20 connectors: conforming to EN 60529 IP40 front: conforming to EN 60529 IP30 side: conforming to EN 60529
IK degree of protection
Front: IK07 conforming to EN 50102
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
12.7 cm
Package 1 Width
16.0 cm
Package 1 Length
27.5 cm
Package 1 Weight
4.019 kg
Warranty
18 months