ATV12P075M2

ATV12 0.75KW 240V 1PH IP20 PLATE

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

ATV12P075M2

Information

Altivar Machine ATV12 is an offer of variable speed drives for commercial equipment and simple machines. It works at a rated power up to 0.75kW / 1hp and a rated voltage from 200V to 240V AC. It is designed on a base plate for mounting on the machine frame. The frame surface area should allow heat to dissipate. It has advanced PID and catch on the fly functions, basic cabling, and easy motor control setting. Based on the needs, it can be delivered without heatsink, with embedded EMC filter, or as standard version. The Altivar 12 drive integrates as standard the Modbus communication protocol. This Altivar Machine ATV12 is designed for simple applications, in industry, commercial machines and HVAC machines such as conveyors, pumps, extractors, access barriers and treadmills. It conforms to IEC, UL and other international standards. SoMove software compatibility enables saving and transfering of configurations to spare drive, reducing maintenance downtime. It features an optimized application of power and torque for ventilation and pumping applications, this allows up to 30% energy savings. The ATV12 range meets basic machine requirements united with simplicity.

Technical Specifications

Range of product

Altivar 12

Product or component type

Variable speed drive

Product specific application

Simple machine

Mounting mode

Cabinet mount

Communication port protocol

Modbus

Supply frequency

50/60 Hz +/- 5 %

[Us] rated supply voltage

200...240 V - 15...10 %

Nominal output current

4.2 A

Motor power hp

1 hp

Motor power kW

0.75 kW

EMC filter

Integrated

IP degree of protection

IP20

Discrete input number

4

Discrete output number

2

analogue input number

1

analogue output number

1

Relay output number

1

Physical interface

2-wire RS 485

Connector type

1 RJ45

Continuous output current

4.2 A at 4 kHz

Method of access

Server Modbus serial

Speed drive output frequency

0.5…400 Hz

Speed range

1…20

Sampling duration

20 ms, tolerance +/- 1 ms for logic input 10 ms for analogue input

Linearity error

+/- 0.3 % of maximum value for analogue input

Frequency resolution

Analog input: converter A/D, 10 bits Display unit: 0.1 Hz

Time constant

20 ms +/- 1 ms for reference change

Transmission rate

9.6 kbit/s 19.2 kbit/s 38.4 kbit/s

Transmission frame

RTU

Number of addresses

1…247

Data format

8 bits, configurable odd, even or no parity

Communication service

Read holding registers (03) 29 words Write single register (06) 29 words Write multiple registers (16) 27 words Read/write multiple registers (23) 4/4 words Read device identification (43)

Type of polarization

No impedance

4 quadrant operation possible

False

Asynchronous motor control profile

Sensorless flux vector control Voltage/frequency ratio (V/f) Quadratic voltage/frequency ratio

Maximum output frequency

4 kHz

Transient overtorque

150…170 % of nominal motor torque depending on drive rating and type of motor

Acceleration and deceleration ramps

S U Linear from 0 to 999.9 s

Motor slip compensation

Preset in factory Adjustable

Switching frequency

2...16 kHz adjustable 4...16 kHz with derating factor

Nominal switching frequency

4 kHz

Braking to standstill

By DC injection

Brake chopper integrated

False

Line current

10.2 A at 100 V (heavy duty) 8.5 A at 120 V (heavy duty)

Maximum input current

8.5 A

Maximum output voltage

240 V

Apparent power

2.0 kVA at 240 V (heavy duty)

Maximum transient current

6.3 A during 60 s (heavy duty) 6.9 A during 2 s (heavy duty)

Network frequency

50...60 Hz

Relative symmetric network frequency tolerance

5 %

Prospective line Isc

1 kA

Base load current at high overload

4.2 A

Power dissipation in W

Natural: 44.0 W

With safety function Safely Limited Speed (SLS)

False

With safety function Safe brake management (SBC/SBT)

False

With safety function Safe Operating Stop (SOS)

False

With safety function Safe Position (SP)

False

With safety function Safe programmable logic

False

With safety function Safe Speed Monitor (SSM)

False

With safety function Safe Stop 1 (SS1)

False

With sft fct Safe Stop 2 (SS2)

False

With safety function Safe torque off (STO)

False

With safety function Safely Limited Position (SLP)

False

With safety function Safe Direction (SDI)

False

Protection type

Line supply overvoltage Line supply undervoltage Overcurrent between output phases and earth Overheating protection Short-circuit between motor phases Against input phase loss in three-phase Thermal motor protection via the drive by continuous calculation of I²t

tightening torque

0.8 N.m

insulation

Electrical between power and control

Quantity per set

Set of 1

Width

72 mm

height

143 mm

Depth

102.2 mm

Net weight

0.7 kg

Operating altitude

> 1000...2000 m with current derating 1 % per 100 m <= 1000 m without derating

Operating position

Vertical +/- 10 degree

product certifications

NOM CSA C-Tick UL GOST RCM KC

Marking

CE

standards

UL 508C UL 618000-5-1 EN/IEC 61800-5-1 EN/IEC 61800-3

Assembly style

On base plate

Electromagnetic compatibility

Electrical fast transient/burst immunity test level 4 conforming to EN/IEC 61000-4-4 Electrostatic discharge immunity test level 3 conforming to EN/IEC 61000-4-2 Immunity to conducted disturbances level 3 conforming to EN/IEC 61000-4-6 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to EN/IEC 61000-4-3 Surge immunity test level 3 conforming to EN/IEC 61000-4-5 Voltage dips and interruptions immunity test conforming to EN/IEC 61000-4-11

Environmental class (during operation)

Class 3C3 according to IEC 60721-3-3 Class 3S2 according to IEC 60721-3-3

Maximum acceleration under shock impact (during operation)

150 m/s² at 11 ms

Maximum acceleration under vibrational stress (during operation)

10 m/s² at 13...200 Hz

Maximum deflection under vibratory load (during operation)

1.5 mm at 2...13 Hz

Overvoltage category

Class III

Regulation loop

Adjustable PID regulator

Electromagnetic emission

Radiated emissions environment 1 category C2 conforming to EN/IEC 61800-3 2...16 kHz shielded motor cable Conducted emissions with integrated EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 2, 4, 8, 12 and 16 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2...12 kHz shielded motor cable <5 m Conducted emissions with integrated EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 2, 4 and 16 kHz shielded motor cable <10 m Conducted emissions with additional EMC filter environment 1 category C1 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <20 m Conducted emissions with additional EMC filter environment 1 category C2 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m Conducted emissions with additional EMC filter environment 2 category C3 conforming to EN/IEC 61800-3 4...12 kHz shielded motor cable <50 m

Vibration resistance

1 gn (f = 13…200 Hz) conforming to EN/IEC 60068-2-6 1.5 mm peak to peak (f = 3…13 Hz) - drive unmounted on symmetrical DIN rail - conforming to EN/IEC 60068-2-6

Shock resistance

15 gn conforming to EN/IEC 60068-2-27 for 11 ms

Relative humidity

5…95 % without condensation conforming to IEC 60068-2-3 5…95 % without dripping water conforming to IEC 60068-2-3

Noise level

0 dB

Pollution degree

2

Ambient air transport temperature

-25…70 °C

Ambient air temperature for operation

-10…40 °C without derating 40…60 °C with current derating 2.2 % per °C

Ambient air temperature for storage

-25…70 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

12.000 cm

Package 1 Width

18.700 cm

Package 1 Length

19.500 cm

Package 1 Weight

974.000 g

Unit Type of Package 2

P06

Number of Units in Package 2

45

Package 2 Height

75.000 cm

Package 2 Width

60.000 cm

Package 2 Length

80.000 cm

Package 2 Weight

56.155 kg

Warranty

18 months

Document Links