Information

This product is part of preventa XPCMC configurable safety controller range. It is a configurable safety controller. It is supplied with 24 V DC. It has 32 safety inputs. It conforms to Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1, PLE safety level conforming to EN/ISO 13849-1 and SIL 3 level conforming to IEC 61508. It embeds 1 RJ45 port for serial link communication with Modbus protocol. Transmission rate are 1200/2400/4800/9600 and 19200bps, and another SUB-D 9-pin male port for CANopen communication. Transmission rate are 20/50/125 and 250kbps. This product measures 153mm depth, 151.5mm height, and 74mm width. It weighs 0.84kg. This safety controller is designed for monitoring multiple safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. This product is certified by CSA, UL and TÜV. It conforms to EN 954-1/EN/ISO 13849-1, EN/IEC 61496-1, IEC 61508, EN/IEC 60204-1, EN 1760-1/ISO 13856-1, EN 574/ISO 13851 and EN/IEC 60947-5-1 standards. The Safety controller XPSMC is configurable and addressable using software XPSMCWIN running on a PC and using a USB/RJ45 cable type TCSMCNAM3M002P to connect to the safety controller. It installs with a mounting plate for mounting on rail. Preventa XPSMC configurable safety controller is designed to provide a solution for safety applications requiring conformity to Performance Level PL e/Category 4 EN ISO 13849-1 and SIL3 EN/IEC 61508. The configurable safety controller consists of 6 variants with 16 or 32 digital inputs and 8 digital outputs and communication possibilities of Modbus RTL Serial, Profibus DP and CANopen.

Technical Specifications

Range of product

Preventa Safety automation

Product or component type

Configurable safety controller

safety module name

XPSMC

Safety use category

Category 4 maximum conforming to EN 954-1/EN/ISO 13849-1 PLE maximum conforming to EN/ISO 13849-1 SIL 3 maximum conforming to IEC 61508

Type of start

Configurable

standards

EN/IEC 60947-5-1 EN 574/ISO 13851 EN 1760-1/ISO 13856-1 EN/IEC 61496-1 IEC 61508 EN 954-1/EN/ISO 13849-1 EN/IEC 60204-1

product certifications

UL TÜV CSA

[Us] rated supply voltage

24 V DC - 20...20 %

Number of inputs

32

Communication port protocol

CANopen with 1 SUB-D 9-pin male port(s), serial link, transmission rate: 20 kbps, 50 kbps, 125 kbps, 250 kbps, 500 kbps, 800 kbps or 1 Mbps Modbus with 1 RJ45 port(s), serial link, transmission rate: 1200 bps, 2400 bps, 4800 bps, 9600 bps or 19200 bps

Safety level

Can reach PL e/category 4 conforming to EN 954-1/EN/ISO 13849-1 Can reach SIL 3 conforming to IEC 61508

Function of module

Dynamic monitoring of hydraulic valves on linear presses Eccentric press Emergency stop monitoring, with or without time delay, 1 or 2-channel wiring Enabling switch monitoring, 2 or 3 contacts Foot switch monitoring Guard monitoring for injection presses and blowing machines Guard monitoring with 1 or 2 limit switches Hydraulic press Magnetic switch monitoring Monitoring safety stop at top dead centre on eccentric press Muting function of light curtains Position selector Safety mat monitoring Safety time delays Shaft/chain breaking monitor Zero speed detection Light curtain monitoring category 4 conforming to EN/IEC 61496 Two-hand control category 3 conforming to EN 574/ISO 13851

Synchronisation time between inputs

Depending on configuration selected

Power consumption in W

12 W

Input protection type

External fuse 16 A

[Uc] control circuit voltage

28.8 V

Maximum line resistance

100 Ohm <2000 m

Output type

2 relays, 2 NO contacts (4 NO total) circuit(s) Solid state, 6 circuit(s), volt-free

Breaking capacity

2 A at 24 V for static output circuit 1.5 A at 24 V (DC-13) time constant: 50 ms for relay output

Output thermal current

4 A for both outputs simultaneously 6 A for 1 output and 2 A for the other for relay output

[Ith] conventional free air thermal current

16 A for relay output 6.5 A for static output circuit

Associated fuse rating

16 A gL for power supply 4 A gL for relay output 6 A fast blow for relay output

Minimum output current

10 mA for relay output

Minimum output voltage

17 V for relay output

Response time

Configurable : 20 ms or 30 ms with software XPSMCWIN

[Ui] rated insulation voltage

300 V (pollution degree 2) conforming to IEC 60647-5-1, DIN VDE 0110 part 1

[Uimp] rated impulse withstand voltage

4 kV overvoltage category III conforming to IEC 60647-5-1, DIN VDE 0110 part 1

Method of access

Slave

Exchange size

14 words

Number of addresses

1…127 for CANopen 1…247 for Modbus

Parity

Even for Modbus No for Modbus Odd for Modbus

Data format

1 start bit/8 data bits 1 stop bit even or odd 2 stop bits without parity RTU (Remote Terminal Unit) mode

Supported modbus function

01: 8-bit output data/32-bit input data 02: 32-bit input data/8-bit output data 03: information and errors

Local signalling

48 LEDs

mounting support

Mounting plate

Depth

153 mm

height

151.5 mm

Width

74 mm

Net weight

0.84 kg

IP degree of protection

IP20 conforming to EN/IEC 60529

Ambient air temperature for operation

-10…55 °C

Ambient air temperature for storage

-25…85 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

9.4 cm

Package 1 Width

17.8 cm

Package 1 Length

25.8 cm

Package 1 Weight

1.28 kg

Unit Type of Package 2

S04

Number of Units in Package 2

6

Package 2 Height

30.0 cm

Package 2 Width

40.0 cm

Package 2 Length

60.0 cm

Package 2 Weight

8.305 kg

Warranty

18 months