LTMR100MFM

CONTROLLER MODBUS 5 100A 115 230V

Trade Price

£528.38

Per

1

Unit

EA

Pack Quantity

1

LTMR100MFM

Information

TeSys T is a motor management system that provides full motor monitoring, control, and protection when used with short circuit protection and a contactor. TeSys T manages most critical processes while reducing downtime and increasing productivity. TeSys T is a flexible system that integrates seamlessly into your automation system through five major communication protocols. TeSys T predicts what will happen in the process, as it accurately monitors current, voltage, and power over a wide range. This controller is the central component in the motor management system. The module manages the basic functions of the motor management system. It manages the measurement of 3 phase current via integral current transformers from 0.4 to 100 A or up to 810 A by external current transformers. It also measures ground current with internal or external ground sensors, motor temperature and the inputs and outputs for the various motor control modes, detected fault management and other functions. Modbus protocol is used by this controller. This module has 6 discrete logic inputs, 3 relay logic outputs and a relay output for detected fault signaling overload relay. The current range of this controller is 5 to 100 amperes. 120 to 240 VAC is used to power this controller. Controller has the following certifications: UL, CSA NOM, ATEX, BV, EAC, RINA, LROS, DNV, ABS, GL, KERI, RMRoS, C-Tick and CCC.

Technical Specifications

Range

TeSys

Product name

TeSys T

Device short name

LTMR

Product or component type

Motor controller

Device application

Equipment monitoring and control

Measurement current

5…100 A

[Us] rated supply voltage

100...240 V AC 50/60 Hz

Current consumption

8...62.8 mA

Supply voltage limits

93.5…264 V AC

Communication port protocol

Modbus

Bus type

Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, RJ45 with 2 shielded twisted pairs Modbus 2-wire RS 485 interface, addressing 1...247, transmission rate 1.2...19.2 kbit/s, terminal block with 2 shielded twisted pairs

[Ui] rated insulation voltage

690 V conforming to EN/IEC 60947-1 690 V conforming to CSA C22.2 No 14 690 V conforming to UL 508

[Uimp] rated impulse withstand voltage

4 kV supply, inputs and outputs conforming to EN/IEC 60947-4-1 6 kV current or voltage measurement circuit conforming to EN/IEC 60947-4-1 0.8 kV communication circuit conforming to EN/IEC 60947-4-1

Short-circuit withstand

100 kA conforming to EN/IEC 60947-4-1

Associated fuse rating

4 A gG for output 0.5 A gG for control circuit

Protection type

Load fluctuation Earth-leakage protection Overload (long time) Overload Locked rotor Thermal protection Thermal overload protection Power factor variation Reverse polarity protection Phase failure Phase unbalance

Network and machine diagnosis type

Motor control command recording Starting current and time Trip history information Phase fault and earth fault trip counters Running hours counter/operating time Remaining operating time before overload tripping Fault recording Trip context information Event recording Waiting time after overload tripping

Logic input number

6

Input current

3.1 mA at 100 V 7.5 mA at 240 V

Current state 0 guaranteed

Logic input: 0...40 V and <= 15 mA for 25 ms

Current state 1 guaranteed

Logic input: 79...264 V and >= 2 mA for 25 ms

maximum output switching frequency

2 Hz

Load current

5 A at 250 V AC for logic output 5 A at 30 V DC for logic output

Permissible power

480 VA (AC-15), Ie = 2 A, 500000 cycles (output) 30 W (DC-13), Ie = 1.25 A, 500000 cycles (output)

Maximum operating rate

1800 cyc/h

Contacts type and composition

1 NO + 1 NC fault signal 3 NO

Metering type

Temperature Earth-fault current Average current Iavg Imbalance current Phase current I1, I2, I3 RMS

Measurement accuracy

5...15 % earth fault current internal measurement 1 % voltage (100...830 V) 3 % power factor 5 % earth fault current external measurement +/- 30 min/year internal clock 0,02 temperature 5 % active and reactive power 0,02 current

Overvoltage category

III

Connection pitch

5.08 mm

Connections - terminals

Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.25…2.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 1 cable(s) 0.2…2.5 mm² (AWG 24...AWG 14) solid without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) flexible with cable end Control circuit: connector 2 cable(s) 0.2…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.5…1.5 mm² (AWG 24...AWG 14) flexible without cable end Control circuit: connector 2 cable(s) 0.2…1 mm² (AWG 24...AWG 14) solid without cable end

Tightening torque

Control circuit: 0.5…0.6 N.m flat screwdriver 3 mm

Pollution degree

3

Electromagnetic compatibility

Electrostatic discharge, 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF fields, 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transients immunity test (other circuits), level 3, 2 kV, conforming to EN/IEC 61000-4-4 Fast transients immunity test (on supply and relay outputs), level 4, 4 kV, conforming to EN/IEC 61000-4-4 Voltage dips and interruptions immunity test, 70 %, 500 ms, conforming to EN/IEC 61000-4-11 Conducted RF disturbances, 10 V, conforming to EN/IEC 61000-4-6 Temperature sensor: surges (serial mode), 0.5 kV, conforming to EN/IEC 61000-4-5 Temperature sensor: surges (common mode), 1 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (serial mode), 1 kV, conforming to EN/IEC 61000-4-5 Communication: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (serial mode), 2 kV, conforming to EN/IEC 61000-4-5 Relay outputs and supply: surges (common mode), 4 kV, conforming to EN/IEC 61000-4-5 Control circuit: surges (common mode), 2 kV, conforming to EN/IEC 61000-4-5

Width

91 mm

height

61 mm

Depth

122.5 mm

Net weight

0.53 kg

Web services

Web server

Compatibility code

LTMR

standards

IACS E10 IEC 60947-4-1 UL 508 EN 60947-4-1 CSA C22.2 No 14

product certifications

LROS (Lloyds register of shipping) UL ABS ATEX EAC CCC BV RINA DNV C-Tick RMRoS CSA GL NOM KERI

Protective treatment

12 x 24 hour cycles conforming to EN/IEC 60068-2-30 48 h conforming to EN/IEC 60070-2-11 TH conforming to EN/IEC 60068

Fire resistance

650 °C conforming to EN/IEC 60695-2-12 960 °C conforming to UL 94

Ambient air temperature for operation

-20…60 °C

Ambient air temperature for storage

-40…80 °C

Operating altitude

<= 2000 m without derating

Mechanical robustness

Vibrations mounted on symmetrical rail: 1 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Vibrations plate mounted: 4 Gn, 5...300 Hz conforming to EN/IEC 60068-2-6 Shocks half sine wave acceleration: 15 Gn for 11 ms conforming to EN/IEC 60068-2-27

IP degree of protection

IP20

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7.2 cm

Package 1 Width

10.0 cm

Package 1 Length

13.6 cm

Package 1 Weight

536.0 g

Unit Type of Package 2

S02

Number of Units in Package 2

10

Package 2 Height

15.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

5.586 kg

Warranty

18 months

Document Links