Trade Price
£19.23
Per
1
Unit
EA
Pack Quantity
1
Range of product
Harmony XAC
Product or component type
Contact block
Component name
XACS
Electrical circuit type
Control circuit
Contact block type
Single
Type of operator
Spring return
Product compatibility
XACA ZA2B... head
Mechanical interlocking
Without mechanical interlock
Contacts type and composition
1 NC
Mounting of block
Front mounting
contact operation
Slow-break
Connections - terminals
Screw clamp terminals, 1 x 2.5 mm² with or without cable end Screw clamp terminals, 2 x 1.5 mm² with or without cable end
Horizontal fixing centres
40 mm
Vertical fixing centres
30 mm
Mechanical durability
1000000 cycles
Contact code designation
A300 AC-15, Ue = 240 V, Ie = 3 A conforming to IEC 60947-5-1 appendix A Q300 DC-13, Ue = 250 V, Ie = 0.27 A conforming to IEC 60947-5-1 appendix A
[Ithe] conventional enclosed thermal current
10 A
[Ui] rated insulation voltage
500 V (pollution degree 3) conforming to IEC 60947-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Maximum resistance across terminals
25 MOhm
Short-circuit protection
10 A fuse protection by cartridge fuse type gG
Rated operational power in W
42 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 120 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 45 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 48 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C 60 W DC-13 for 1000000 cycles, operating rate <60 cyc/mn at 24 V, load factor = 0.5 (inductive load) conforming to IEC 60947-5-1 appendix C
Rated operational power in VA
140 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 24 V 50/60 Hz, load factor = 0.5 (inductive load) 385 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 48 V 50/60 Hz, load factor = 0.5 (inductive load) 455 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 230 V 50/60 Hz, load factor = 0.5 (inductive load) 525 VA AC-15 for 1000000 cycles, operating rate <60 cyc/mn at 127 V 50/60 Hz, load factor = 0.5 (inductive load)
Terminals description ISO n°1
(11-12)NC
Terminal identifier
(13-14)NO (11-12)NC
Net weight
0.07 kg
standards
IEC 60947-5-1 CSA C22.2 No 14 IEC 60947-5-1
Ambient air temperature for operation
-25…70 °C
Ambient air temperature for storage
-40…70 °C
Vibration resistance
15 gn (f= 10…500 Hz) conforming to IEC 60068-2-6
Shock resistance
100 gn conforming to IEC 60068-2-27
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.1 cm
Package 1 Width
7.3 cm
Package 1 Length
9.8 cm
Package 1 Weight
58.0 g
Unit Type of Package 2
S01
Number of Units in Package 2
30
Package 2 Height
15.0 cm
Package 2 Width
15.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
1.795 kg
Warranty
18 months
Datasheet
Product Catalogue