Trade Price
£166.42
Per
1
Unit
EA
Pack Quantity
1
This product is part of the Zelio Logic range, an offer of smart relays for simple automation systems from 10 to 40 I/Os. The analogue I/O extension module provides 2 input/outputs. It is an extension module with an analogue output range of 0 to 10V and a maximum load current of 10mA for analogue output. It provides 10bit on the input range and 10bit on the output range. The temperature probe is Pt 100, 3-wire conforming to IEC 751. It is furnished with screw terminal for electrical connections. It is an IP20 and IP40 rated product. It weighs 0.11kg. This product meets EN/IEC 61000-4-12, EN/IEC 61000-4-5, EN/IEC 61000-4-3, EN/IEC 61000-4-4 level 3, EN/IEC 61000-4-6 level 3, EN/IEC 61000-4-2 level 3, EN/IEC 60068-2-6 Fc, EN/IEC 61000-4-11 and EN/IEC 60068-2-27 Ea standards. Simple to select, install and program, Zelio Logic is suitable for all your applications. Flexible, it offers you the choice of 2 ranges, compact or modular, extendable and 2 programming languages (FBD or LADDER). Easy to use, Zelio Logic provides a real alternative to solutions based on cabled logic or specific cards.
Range of product
Zelio Logic
Product or component type
Analogue I/O extension module
analogue input number
2
analogue input type
Common mode
Analogue input range
0...10 V 0...20 mA -25...125 °C
Temperature probe type
Pt 100, 3-wire conforming to IEC 751
Maximum permissible voltage
30 V for analogue input circuit
[Imp] maximum permanent current
30 mA for analogue input circuit
analogue input resolution
10 bits on the input range
Input impedance
18 kOhm, input range: 0...10 V for analogue input circuit 247 Ohm, input range: 0...20 mA for analogue input circuit
analogue output number
2
Analogue output range
0...10 V
Analogue output resolution
10 bits on the output range
Load type
Resistive load for analogue output
Maximum load current
10 mA for analogue output
Short-circuit protection
With analogue output
LSB value
0.15 °C, - 25...125 °C for analogue input circuit 20 µA, 0...20 mA for analogue input circuit 9.8 mV, 0...10 V for analogue input circuit 9.8 mV, 0...10 V for analogue output
Conversion time
Smart relay cycle time for analogue input circuit Smart relay cycle time for analogue output
Conversion error
+/- 1 % of the full scale value, input range: 0...10 V (25 °C) for analogue output +/- 1 % of the full scale value, input range: 0...10 V (55 °C) for analogue output +/- 1 %, input range: 0...10 V (25 °C) for analogue input circuit +/- 1 %, input range: 0...10 V (55 °C) for analogue input circuit +/- 1 %, input range: 0...20 mA (25 °C) for analogue input circuit +/- 1 %, input range: 0...20 mA (55 °C) for analogue input circuit +/- 1.5 °C, input range: - 25...125 °C (25 °C) for analogue input circuit +/- 1.5 °C, input range: - 25...125 °C (55 °C) for analogue input circuit
Repeat accuracy
< +/- 0.3 °C, input range: - 25...125 °C at 25 °C for analogue input circuit <= +/- 1 %, input range: 0...10 V at 25 °C for analogue input circuit <= +/- 1 %, input range: 0...10 V at 55 °C for analogue output <= +/- 1 %, input range: 0...20 mA at 25 °C for analogue input circuit
Operating distance
10 m with screened cable for analogue input circuit 10 m with screened cable for analogue output
Reverse polarity protection
Analogue input circuit: with
Connections - terminals
Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) semi-solid Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) solid Screw terminals, 2 x 0.25...2 x 1.5 mm² (AWG 23...AWG 16) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end
tightening torque
0.5 N.m
Net weight
0.11 kg
product certifications
GOST UL C-Tick CSA
standards
EN/IEC 61000-4-12 EN/IEC 61000-4-5 EN/IEC 61000-4-3 EN/IEC 61000-4-4 level 3 EN/IEC 61000-4-6 level 3 EN/IEC 61000-4-2 level 3 EN/IEC 60068-2-6 Fc EN/IEC 61000-4-11 EN/IEC 60068-2-27 Ea
IP degree of protection
IP20 (terminal block) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529
Environmental characteristic
EMC directive conforming to EN/IEC 61000-6-2 EMC directive conforming to EN/IEC 61000-6-3 EMC directive conforming to EN/IEC 61000-6-4 EMC directive conforming to EN/IEC 61131-2 zone B Low voltage directive conforming to EN/IEC 61131-2
Disturbance radiated/conducted
Class B conforming to EN 55022-11 group 1
Pollution degree
2 conforming to EN/IEC 61131-2
Ambient air temperature for operation
-20…40 °C conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2
Ambient air temperature for storage
-40…70 °C
Operating altitude
2000 m
Maximum altitude transport
3048 m
Relative humidity
95 % without condensation or dripping water
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.1 cm
Package 1 Width
6.5 cm
Package 1 Length
11.0 cm
Package 1 Weight
105.0 g
Unit Type of Package 2
S03
Number of Units in Package 2
48
Package 2 Height
30.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
5.503 kg
Warranty
18 months