SR2A101FU

SR2 10 I-O 100-240 VAC

Trade Price

£158.17

Per

1

Unit

EA

Pack Quantity

1

SR2A101FU

Information

This Zelio Logic SR2 compact smart relay / programmable controller uses a supply voltage of 100V to 240V alternating current. It has 10 inputs / outputs with screw-clamp terminals and has an integrated LCD display. It has compact design, allowing installation on DIN rail. It also offers simple programming, display and diagnosing of malfunctions display and navigation buttons. Its simple ladder programming makes it adapted for non-specialists.

Technical Specifications

Range of product

Zelio Logic

Product or component type

Compact smart relay

Local display

With

Number or control scheme lines

0…240 with ladder programming

Cycle time

6…90 ms

Backup time

10 years at 25 °C

Clock drift

12 min/year at 0…55 °C 6 s/month at 25 °C

Checks

Program memory on each power up

[Us] rated supply voltage

100...240 V AC

Supply voltage limits

85…264 V

Supply frequency

50/60 Hz

Maximum supply current

30 mA at 240 V (without extension) 80 mA at 100 V (without extension)

Power consumption in VA

7 VA without extension

Isolation voltage

1780 V

Protection type

Against inversion of terminals (control instructions not executed)

Discrete input number

6

Discrete input voltage

100...240 V AC

Discrete input current

0.6 mA

Discrete input frequency

47...53 Hz 57...63 Hz

Voltage state 1 guaranteed

>= 79 V for discrete input

Voltage state 0 guaranteed

<= 40 V for discrete input

Current state 1 guaranteed

>= 0.17 mA (discrete input)

Current state 0 guaranteed

<= 0.5 mA (discrete input)

analogue input number

0

Input impedance

350 kOhm for discrete input

Number of outputs

4 relay

Output voltage limits

5...30 V DC (relay output) 24...250 V AC

Contacts type and composition

NO for relay output

Output thermal current

8 A for all 4 outputs for relay output

Electrical durability

AC-12: 500000 cycles at 230 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1 AC-15: 500000 cycles at 230 V, 0.9 A for relay output conforming to EN/IEC 60947-5-1 DC-12: 500000 cycles at 24 V, 1.5 A for relay output conforming to EN/IEC 60947-5-1 DC-13: 500000 cycles at 24 V, 0.6 A for relay output conforming to EN/IEC 60947-5-1

Switching capacity in mA

>= 10 mA at 12 V (relay output)

Operating rate in Hz

0.1 Hz (at Ie) for relay output 10 Hz (no load) for relay output

Mechanical durability

10000000 cycles for relay output

[Uimp] rated impulse withstand voltage

4 kV conforming to EN/IEC 60947-1 and EN/IEC 60664-1

clock

Without

Response time

50 ms with ladder programming (from state 0 to state 1) for discrete input 50 ms with ladder programming (from state 1 to state 0) for discrete input 50...255 ms with FBD programming (from state 0 to state 1) for discrete input 50...255 ms with FBD programming (from state 1 to state 0) for discrete input 10 ms (from state 0 to state 1) for relay output 5 ms (from state 1 to state 0) for relay output

Connections - terminals

Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) semi-solid Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 25...AWG 14) solid Screw terminals, 1 x 0.25...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) solid Screw terminals, 2 x 0.25...2 x 0.75 mm² (AWG 24...AWG 18) flexible with cable end

tightening torque

0.5 N.m

Overvoltage category

III conforming to EN/IEC 60664-1

Net weight

0.25 kg

Immunity to microbreaks

10 ms

product certifications

C-Tick CSA GL UL GOST

standards

EN/IEC 61000-4-6 level 3 EN/IEC 61000-4-11 EN/IEC 61000-4-3 EN/IEC 61000-4-12 EN/IEC 61000-4-4 level 3 EN/IEC 61000-4-5 EN/IEC 60068-2-6 Fc EN/IEC 61000-4-2 level 3 EN/IEC 60068-2-27 Ea

IP degree of protection

IP20 (terminal block) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529

Environmental characteristic

EMC directive conforming to EN/IEC 61000-6-2 EMC directive conforming to EN/IEC 61000-6-3 EMC directive conforming to EN/IEC 61000-6-4 EMC directive conforming to EN/IEC 61131-2 zone B Low voltage directive conforming to EN/IEC 61131-2

Disturbance radiated/conducted

Class B conforming to EN 55022-11 group 1

Pollution degree

2 conforming to EN/IEC 61131-2

Ambient air temperature for operation

-20…40 °C in non-ventilated enclosure conforming to IEC 60068-2-1 and IEC 60068-2-2 -20…55 °C conforming to IEC 60068-2-1 and IEC 60068-2-2

Ambient air temperature for storage

-40…70 °C

Operating altitude

2000 m

Maximum altitude transport

3048 m

Relative humidity

95 % without condensation or dripping water

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

7.0 cm

Package 1 Width

10.0 cm

Package 1 Length

8.8 cm

Package 1 Weight

243.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

30

Package 2 Height

30.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

7.782 kg

Warranty