Trade Price
POA
Per
1
Unit
Pack Quantity
Range
TeSys
Product name
TeSys F
Product or component type
Star delta starter
Device short name
LC3F
contactor application
Motor control
utilisation category
AC-3
Device presentation
Pre-wired
Poles description
3 x 3P
power pole contact composition
3 x 3 NO
[Ue] rated operational voltage
Power circuit: <= 1000 V AC 16 Hz 2/3...200 Hz
[Ie] rated operational current
400 A (at <55 °C) at <= 440 V AC AC-3 for power circuit
Motor power kW
185 kW at 220/230 V AC 50/60 Hz 315 kW at 380/400 V AC 50/60 Hz 355 kW at 415 V AC 50/60 Hz 375 kW at 440 V AC 50/60 Hz
Control circuit type
AC at 50/60 Hz
[Uc] control circuit voltage
220/230 V AC 50/60 Hz
Auxiliary contact composition
1 NC for KM1 star contactor 1 NO for KM1 star contactor 2 NC for KM2 line contactor 1 NO for KM2 line contactor 1 NC for KM3 delta contactor 2 NO for KM3 delta contactor
[Uimp] rated impulse withstand voltage
8 kV
[Ui] rated insulation voltage
1000 V conforming to IEC 60947-4-1 1500 V conforming to VDE 0110 group C
Interlocking type
Without start delta mechanical interlock
mounting support
Plate
standards
EN 60947-1 EN 60947-4-1 JIS C8201-4-1 IEC 60947-4-1 IEC 60947-1
product certifications
CSA UL RINA ABS RMRoS CB LROS (Lloyds register of shipping) DNV CCC
[Ith] conventional free air thermal current
500 A 40 °C
Irms rated making capacity
4000 A conforming to IEC 60947-4-1
Rated breaking capacity
3200 A conforming to IEC 60947-4-1
[Icw] rated short-time withstand current
3600 A 40 °C - 10 s 2400 A 40 °C - 30 s 1700 A 40 °C - 1 min 1200 A 40 °C - 3 min 1000 A 40 °C - 10 min
Associated fuse rating
500 A gG at <= 440 V 400 A aM at <= 440 V
Connections - terminals
Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 2 1…2.5 mm² - cable stiffness: flexible with cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: flexible without cable end Control circuit: screw clamp terminals 1 1…4 mm² - cable stiffness: solid without cable end Control circuit: screw clamp terminals 2 1…4 mm² - cable stiffness: solid without cable end Power circuit: bar 2 - busbar cross section: 30 x 5 mm Power circuit: bolted connection Power circuit: lugs-ring terminals 2 150 mm²
connections bolt diameter
M10
Tightening torque
Control circuit: 1.2 N.m Power circuit: 35 N.m
Operating time
40...65 ms closing 100...170 ms opening
Mechanical durability
10 Mcycles
Maximum operating rate
2400 cyc/h 55 °C
Starting time
20 s
Control circuit voltage limits
Operational: 0.85...1.1 Uc at 40...400 Hz (at <55 °C) Drop-out: 0.35...0.55 Uc at 40...400 Hz (at <55 °C)
Inrush power in VA
1075 VA 40...400 Hz cos phi 0.9 (at 20 °C)
Hold-in power consumption in VA
15 VA 40...400 Hz cos phi 0.9 (at 20 °C)
Heat dissipation
14 W
Width
725 mm
height
180 mm
Depth
276 mm
Net weight
37 kg
IP degree of protection
IP20 front face with shrouds conforming to IEC 60529 IP20 front face with shrouds conforming to VDE 0106
Protective treatment
TH
Ambient air temperature for storage
-60…80 °C
Ambient air temperature for operation
-5…55 °C -40…70 °C at Uc
Operating altitude
3000 m with derating factor
Mechanical robustness
Shocks contactor closed: 15 Gn for 11 ms Vibrations contactor closed: 5 Gn, 5...300 Hz Shocks contactor open: 6 Gn for 11 ms Vibrations contactor open: 1.5 Gn, 5...300 Hz
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Warranty
18 months
Datasheet