Trade Price
£283.47
Per
1
Unit
EA
Pack Quantity
1
This product is part of the Modicon TM3 range, an offer of expansion I/O modules for Modicon M221, M241, M251 and M262. The safety module provides 3 normally opened contacts and unlimited synchronisation time between inputs. It is a safety module with a rated supply voltage of 24V DC, an external supply current consumption of 100mA at 24V DC on power supply and a power consumption 0.2W at 5V DC, 3.6W at 24V DC. The main functions of this module are emergency stop, movable guard, multiple emergency stop, proximity sensor and electro-sensitive protection equipment (ESPE) monitoring. It is furnished with spring terminal for electrical connection. It is an IP20 rated product. Its dimensions are 43.7mm (Width) x 73mm (Depth) x 94mm (Height). It weighs 0.19kg. It is suitable for emergency stop, switch and safety light curtain monitoring applications. This product is certified by RCM, CSA, UL, TÜV, ANSI Haz Loc Class 1 Division 2, EAC. It supports wall mount using attached fasteners. Modicon TM3 expansion modules have been designed with a simple interlocking assembly mechanism. A bus expansion connector is used to distribute data and the power supply when assembling the Modicon TM3 modules with logic controllers. Boost the performance of your controller with the Modicon TM3 I/O system specially designed for the Modicon M221, M241 and M251 logic controllers.
Range of product
Modicon TM3 Safety
Product or component type
Safety module
Device short name
TM3SAFL
safety module application
For emergency stop, switch and safety light curtain monitoring
Function of module
Emergency stop monitoring 2-channel wiring Monitoring of a movable guard with 2 switches and automatic start Monitoring of a movable guard Multiple emergency stop monitoring 2-channel wiring Proximity sensor monitoring PNP/PNP Monitoring of electro-sensitive protection equipment (ESPE) PNP/PNP
Safety level
Can reach PL d/category 3 conforming to EN/ISO 13849-1: 2008 Can reach PL d/category 3 conforming to EN/ISO 13849-2: 2012 Can reach SILCL 2 conforming to EN/IEC 62061: 2005 Can reach SIL 2 conforming to EN/IEC 61508: 2010
Safety reliability data
DC = 95 % conforming to EN/ISO 13849-1 PFHd = 5E-9 1/h conforming to IEC 61508-1 1 operation/hour DC-13 24 V DC, <4 A PFHd = 30E-9 1/h conforming to IEC 61508-1 60 operations/hour DC-13 24 V DC, <1 A MTTFd = 500 years conforming to EN/ISO 13849-1 1 operation/hour DC-13 24 V DC, <4 A MTTFd = 85 years conforming to EN/ISO 13849-1 60 operations/hour DC-13 24 V DC, <1 A SFF = 95 % conforming to IEC 61508-1 HFT = 1 conforming to IEC 61508-1 Type = A conforming to IEC 61508-1
Synchronisation time between inputs
Unlimited
Connections - terminals
Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² flexible without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.2...1 x 2.5 mm² solid without cable end 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, with bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.25...1 x 2.5 mm² flexible with cable end, without bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 2 x 0.5...2 x 1.5 mm² flexible with cable end, with double bezel 13-14, 23-24, 33-34 Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² flexible without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.14...1 x 1.5 mm² solid without cable end other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 0.5 mm² flexible with cable end, with bezel other terminals Captive spring terminals, removable terminal block 1 x 0.25...1 x 1.5 mm² flexible with cable end, without bezel other terminals
Output type
Relay instantaneous opening, 3 NO circuit(s), potential free
Number of safety circuits
3 NO for relay instantaneous opening
Maximum switching voltage
230 V utilisation category AC-15 at 50 Hz (relay instantaneous opening) 24 V utilisation category DC-13 (relay instantaneous opening)
[Us] rated supply voltage
24 V - 15...20 % DC
Power consumption in W
0.2 W at 5 V DC 3.6 W at 24 V DC
Input protection type
Internal, electronic
[Uc] control circuit voltage
24 V DC
Maximum cable distance between devices
30 m
Breaking capacity
4 A 24 V 50 ms DC-13 relay output
Output thermal current
6 A per relay for relay output
[Ith] conventional free air thermal current
18 A
Associated fuse rating
4 A gG or gL for relay output conforming to EN/IEC 60947-5-1 6 A fast blow for relay output conforming to EN/IEC 60947-5-1
Minimum output current
10 mA for relay output
Output voltage
10 V relay output
Maximum response time on input open
40 ms
[Ui] rated insulation voltage
300 V (pollution degree 2) conforming to IEC 60647-5-1
[Uimp] rated impulse withstand voltage
4 kV overvoltage category III conforming to IEC 60647-5-1
Current consumption
100 mA at 24 V DC external supply
Local signalling
8 LEDs (green/red) for user
Electrical connection
Spring terminal
Product compatibility
Safety light curtains conforming to EN/IEC 61496-1 (type 4)
Standards
EN/ISO 13849-1:2008 EN/ISO 13849-2:2012 EN/IEC 62061:2005 EN/IEC 61508:2010 EN/IEC 60947-5-1:2010 EN/IEC 61131-2:2007 EN/IEC 60204-1:2005 EN/IEC 60204-1:2009/A1 IEC 61010-1:2010 EN 50581:2012
product certifications
CSA 61010-2-201 (pending) RCM UL 61010-2-201 EAC ANSI Haz Loc Class 1 Division 2 (pending) CSA Haz Loc Class 1 Division 2 (pending) TÜV
Marking
RCM UL CSA EAC CE TÜV EFUP 10
Electromagnetic compatibility
Electrostatic discharge immunity test - test level: 8 kV (air discharge) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test - test level: 6 kV (contact discharge) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80 MHz to 1 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 3 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 1 V/m (2 GHz...3 GHz) conforming to EN/IEC 61000-4-3 Magnetic field at power frequency - test level: 30 A/m (50...60 Hz) conforming to EN/IEC 61000-4-8 Electrical fast transient/burst immunity test - test level: 3 kV (power lines (DC)) conforming to EN/IEC 61000-4-4 Electrical fast transient/burst immunity test - test level: 2 kV (I/O) conforming to EN/IEC 61000-4-4 1.2/50 µs shock waves immunity test - test level: 1 kV (power lines (DC)) conforming to EN/IEC 61000-4-5 Conducted RF disturbances - test level: 10 V (0.15...80 MHz) conforming to EN/IEC 61000-4-6 Radiated emission - test level: 40 dBµV/m class A (24 V) conforming to EN 55011 Radiated emission - test level: 47 dBµV/m class A (24 V) conforming to EN 55011
Mounting support
Top hat type TH35-7.5 rail conforming to IEC 60715 Top hat type TH35-15 rail conforming to IEC 60715 wall mount using attached fasteners
height
94 mm
Depth
73 mm
Width
43.7 mm
Net weight
0.19 kg
standards
EN 60204-1 EN 1088/ISO 14119 EN/ISO 13850 EN/IEC 60947-1 EN/IEC 60947-5-1
Resistance to electrostatic discharge
8 kV in air conforming to EN/IEC 61000-4-2 6 kV on contact conforming to EN/IEC 61000-4-2
Resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2 GHz...3 GHz conforming to EN/IEC 61000-4-3
Resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Resistance to fast transients
3 kV for power lines (DC) (DC) conforming to EN/IEC 61000-4-4 2 kV for I/O lines conforming to EN/IEC 61000-4-4
Surge withstand
1 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 DC 1 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5 DC
Resistance to conducted disturbances
10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6
Electromagnetic emission
Radiated emissions - test level: 50 dBµV/m class A ( 24 V DC) at 30…230 Hz conforming to IEC 61131-3 Radiated emissions - test level: 57 dBµV/m class A ( 24 V DC) at 230…1000 Hz conforming to IEC 61131-3
Ambient air temperature for operation
-10…55 °C horizontal installation
Ambient air temperature for storage
-25…70 °C
Relative humidity
10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage)
IP degree of protection
IP20 (terminals) conforming to EN/IEC 60529
Pollution degree
2
Operating altitude
0...2000 m
Storage altitude
0…3000 m
Vibration resistance
+/- 3.5 mm (f= 5…150 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Mechanical robustness
Bumps 6 ms 300 shocks (25 gn) conforming to IEC 60068-2-27
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
7.5 cm
Package 1 Width
10.6 cm
Package 1 Length
12.5 cm
Package 1 Weight
262.0 g
Unit Type of Package 2
S03
Number of Units in Package 2
18
Package 2 Height
30.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
5.272 kg
Warranty
18 months
Datasheet