This TM221 controller is part of the Modicon M221 Logic controller range. It has 24 logic I/O and it is supplied with 24V DC. It is supplied with removable screw terminal blocks for connecting the I/O, a removable screw terminal block for connecting the power supply, a button cell backup battery BR2032 and a cable for connecting the analog inputs. M221 logic controllers have three types of integrated communication port, Ethernet, RS 232/RS 485 serial link and USB mini-B programming port. It enables the control of simple machines. The capacity of M221 logic controllers can be enhanced with the Modicon TM3 expansion module offer.
Range of product
Modicon M221
Product or component type
Logic controller
[Us] rated supply voltage
24 V DC
Discrete input number
14, discrete input 4 fast input conforming to IEC 61131-2 Type 1
Analogue input number
2 at 0...10 V
Discrete output type
Transistor
Discrete output number
10 transistor 2 fast output
Discrete output voltage
24 V DC
Discrete output current
0.5 A
Discrete I/O number
24
Maximum number of I/O expansion module
7 (local I/O-Architecture) 14 (remote I/O-Architecture)
Supply voltage limits
20.4…28.8 V
Inrush current
35 A
Maximum power consumption in W
14 W at 24 V (with max number of I/O expansion module) 4.8 W at 24 V (without I/O expansion module)
Power supply output current
0.52 A 5 V for expansion bus 0.2 A 24 V for expansion bus
Discrete input logic
Sink or source (positive/negative)
Discrete input voltage
24 V
discrete input voltage type
DC
analogue input resolution
10 bits
LSB value
10 mV
Conversion time
1 ms per channel + 1 controller cycle time for analogue input analog input
Permitted overload on inputs
+/- 30 V DC for 5 min (maximum) for analog input +/- 13 V DC (permanent) for analog input
Voltage state 1 guaranteed
>= 15 V for input
Voltage state 0 guaranteed
<= 5 V for input
Discrete input current
7 mA for discrete input 5 mA for fast input
Input impedance
3.4 kOhm for discrete input 100 kOhm for analog input 4.9 kOhm for fast input
Response time
35 µs turn-off, I2...I5 terminal(s) for input 5 µs turn-on, I0, I1, I6, I7 terminal(s) for fast input 35 µs turn-on, other terminals terminal(s) for input 5 µs turn-off, I0, I1, I6, I7 terminal(s) for fast input 100 µs turn-off, other terminals terminal(s) for input 5 µs turn-on, turn-off, Q0...Q1 terminal(s) for output 50 µs turn-on, turn-off, Q2...Q3 terminal(s) for output 300 µs turn-on, turn-off, other terminals terminal(s) for output
Configurable filtering time
0 ms for input 3 ms for input 12 ms for input
discrete output logic
Positive logic (source)
Maximum current per output common
5 A
Output frequency
100 kHz for fast output (PWM/PLS mode) at Q0...Q1 5 kHz for output at Q2...Q3 0.1 kHz for output at Q4...Q9
Absolute accuracy error
+/- 1 % of full scale for analog input
Maximum leakage current
0.1 mA for transistor output
Maximum voltage drop
<1 V
Mechanical durability
20000000 cycles for transistor output
Maximum tungsten load
<12 W for output and fast output
Protection type
Overload and short-circuit protection at 1 A
Reset time
1 s automatic reset
Memory capacity
256 kB for user application and data RAM with 10000 instructions 256 kB for internal variables RAM
Data backed up
256 kB built-in flash memory for backup of application and data
Data storage equipment
2 GB SD card (optional)
Battery type
BR2032 or CR2032X lithium non-rechargeable
Backup time
1 year at 25 °C (by interruption of power supply)
Execution time for 1 KInstruction
0.3 ms for event and periodic task
Execution time per instruction
0.2 µs Boolean
Exct time for event task
60 µs response time
Maximum size of object areas
255 %C counters 512 %M memory bits 8000 %MW memory words 512 %KW constant words 255 %TM timers
Realtime clock
With
Clock drift
<= 30 s/month at 25 °C
Regulation loop
Adjustable PID regulator up to 14 simultaneous loops
Positioning functions
Position PTO 2 axe(s)pulse/direction mode (100 kHz) Position PTO 1 axe(s)CW/CCW mode (100 kHz)
Function available
Frequency generator PLS PWM
Counting input number
4 fast input (HSC mode) at 100 kHz 32 bits
counter function
A/B Single phase Pulse/direction
Integrated connection type
USB port with mini B USB 2.0 connector Non isolated serial link serial 1 with RJ45 connector and RS232/RS485 interface Ethernet with RJ45 connector
Supply
(serial)serial link supply: 5 V, <200 mA
Transmission rate
1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 15 m for RS485 1.2...115.2 kbit/s (115.2 kbit/s by default) for bus length of 3 m for RS232 480 Mbit/s for USB
Communication port protocol
USB port: USB - SoMachine-Network Non isolated serial link: Modbus master/slave - RTU/ASCII or SoMachine-Network Ethernet
Port Ethernet
10BASE-T/100BASE-TX 1 port with 100 m copper cable
Communication service
Modbus TCP slave device Modbus TCP server Modbus TCP client Ethernet/IP adapter DHCP client
Local signalling
1 LED (green) for PWR 1 LED (green) for RUN 1 LED (red) for module error (ERR) 1 LED (green) for SD card access (SD) 1 LED (red) for BAT 1 LED per channel (green) for I/O state 1 LED (green) for SL Ethernet network activity (green) for ACT Ethernet network link (yellow) for Link (Link Status)
Electrical connection
removable screw terminal block for inputs removable screw terminal block for outputs terminal block, 3 terminal(s) for connecting the 24 V DC power supply connector, 4 terminal(s) for analogue inputs Mini B USB 2.0 connector for a programming terminal
Maximum cable distance between devices
Shielded cable: <10 m for fast input Unshielded cable: <30 m for output Unshielded cable: <30 m for digital input Unshielded cable: <1 m for analog input Shielded cable: <3 m for fast output
Insulation
Between input and internal logic at 500 V AC Between fast input and internal logic at 500 V AC Non-insulated between inputs Between output and internal logic at 500 V AC Non-insulated between analogue input and internal logic Non-insulated between analogue inputs
Marking
CE
Mounting support
Top hat type TH35-15 rail conforming to IEC 60715 Top hat type TH35-7.5 rail conforming to IEC 60715 plate or panel with fixing kit
height
90 mm
Depth
70 mm
Width
110 mm
Net weight
0.395 kg
standards
EN/IEC 61131-2 UL 508 CAN/CSA C22.2 No. 213 IACS E10 ANSI/ISA 12-12-01
product certifications
ABS EAC RCM cULus LR DNV-GL CE UKCA cULus HazLoc
Environmental characteristic
Ordinary and hazardous location
Resistance to electrostatic discharge
8 kV in air conforming to EN/IEC 61000-4-2 4 kV on contact conforming to EN/IEC 61000-4-2
Resistance to electromagnetic fields
10 V/m 80 MHz...1 GHz conforming to EN/IEC 61000-4-3 3 V/m 1.4 GHz...2 GHz conforming to EN/IEC 61000-4-3 1 V/m 2...2.7 GHz conforming to EN/IEC 61000-4-3
Resistance to magnetic fields
30 A/m 50/60 Hz conforming to EN/IEC 61000-4-8
Resistance to fast transients
2 kV (power lines) conforming to EN/IEC 61000-4-4 2 kV (relay output) conforming to EN/IEC 61000-4-4 1 kV (I/O) conforming to EN/IEC 61000-4-4 1 kV (Ethernet line) conforming to EN/IEC 61000-4-4 1 kV (serial link) conforming to EN/IEC 61000-4-4
Surge withstand
2 kV power lines (AC) common mode conforming to EN/IEC 61000-4-5 2 kV relay output common mode conforming to EN/IEC 61000-4-5 1 kV I/O common mode conforming to EN/IEC 61000-4-5 1 kV shielded cable common mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) differential mode conforming to EN/IEC 61000-4-5 1 kV power lines (AC) differential mode conforming to EN/IEC 61000-4-5 1 kV relay output differential mode conforming to EN/IEC 61000-4-5 0.5 kV power lines (DC) common mode conforming to EN/IEC 61000-4-5
Resistance to conducted disturbances
10 V 0.15...80 MHz conforming to EN/IEC 61000-4-6 3 V 0.1...80 MHz conforming to Marine specification (LR, ABS, DNV, GL) 10 V spot frequency (2, 3, 4, 6.2, 8.2, 12.6, 16.5, 18.8, 22, 25 MHz) conforming to Marine specification (LR, ABS, DNV, GL)
Electromagnetic emission
Conducted emissions - test level: 79 dBμV/m QP/66 dBμV/m AV ( power lines (AC)) at 0.15…0.5 MHz conforming to EN/IEC 55011 Conducted emissions - test level: 73 dBμV/m QP/60 dBμV/m AV ( power lines (AC)) at 0.5…300 MHz conforming to EN/IEC 55011 Conducted emissions - test level: 120...69 dBµV/m QP ( power lines) at 10…150 kHz conforming to EN/IEC 55011 Conducted emissions - test level: 63 dBμV/m QP ( power lines) at 1.5…30 MHz conforming to EN/IEC 55011 Radiated emissions - test level: 40 dBμV/m QP class A ( 10 m) at 30…230 MHz conforming to EN/IEC 55011 Conducted emissions - test level: 79...63 dBμV/m QP ( power lines) at 150…1500 kHz conforming to EN/IEC 55011 Radiated emissions - test level: 47 dBμV/m QP class A ( 10 m) at 200…1000 MHz conforming to EN/IEC 55011
Immunity to microbreaks
10 ms
Ambient air temperature for operation
-10…55 °C (horizontal installation) -10…35 °C (vertical installation)
Ambient air temperature for storage
-25…70 °C
Relative humidity
10…95 %, without condensation (in operation) 10…95 %, without condensation (in storage)
IP degree of protection
IP20 with protective cover in place
Pollution degree
<= 2
Operating altitude
0...2000 m
Storage altitude
0…3000 m
Vibration resistance
3.5 mm at 5…8.4 Hz on symmetrical rail 3.5 mm at 5…8.4 Hz on panel mounting 1 gn at 8.4…150 Hz on symmetrical rail 1 gn at 8.4…150 Hz on panel mounting
Shock resistance
147 m/s² for 11 ms
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
11.133 cm
Package 1 Width
14.136 cm
Package 1 Length
15.607 cm
Package 1 Weight
621.0 g
Unit Type of Package 2
CAR
Number of Units in Package 2
20
Package 2 Height
29.7 cm
Package 2 Width
39.8 cm
Package 2 Length
57.0 cm
Package 2 Weight
13.211 kg
Unit Type of Package 3
P12
Number of Units in Package 3
240
Package 3 Height
105.0 cm
Package 3 Width
120.0 cm
Package 3 Length
80.0 cm
Package 3 Weight
94 kg
Warranty
18 months
Datasheet