RMNF22TB30

NFC CONTROL RELAY 3-PHASES

Trade Price

POA

Per

1

Unit

Pack Quantity

RMNF22TB30
RMNF22TB30
RMNF22TB30
RMNF22TB30

Information

This 3-phase control relay belongs to the Schneider Electric Harmony Control relays range. This 3-phase control relay is integrated with NFC technology which brings in digital operation instead of analog operation. This is a 8A multifunction 3-phase control relay which monitors 3-phase or 3-phase with Neutral network and has an adjustable time delay of 0.1s to 60min. With Harmony NFC App, different alarms can be combined using AND, OR and NOT logic to form unique monitoring combinations for the two relay outputs which are individually configurable. NFC 3-phase control relay is a single reference supporting 7 functions namely Phase loss, Phase sequence, Asymmetry, Undervoltage, Overvoltage, Under-frequency, and Over-frequency. The 3-phase control relay is IP20 (terminals), IP40 (housing), and IP40(front panel) protected. Furthermore, the 4 digit password enhances security by preventing unauthorized change of settings. This RMNF22 dimensions are 22.5mm (width) x 90mm (height) x 99mm (depth) and weighs 0.125Kg. It conforms to international standard EN/IEC 60255-1 and certifications like UL, CSA, CE, CCC, EAC, and RCM. It is sold as a single unit. Monitoring and testing are now intuitive as exact fault conditions can be identified through front LEDs and analyze data with Harmony NFC App. This saves time and boosts efficiency.

Technical Specifications

Range of produc

Harmony Control Relays

Relay type

Control relay

Product or component type

3-phase control relay

Network number of phases

3 phases

Relay name

RMNF22

Relay monitored parameters

Phase sequence Phase failure detection Overvoltage detection Undervoltage detection Overfrequency and underfrequency Asymmetry

Supported OS

Android

software version

V4.4 and above

App for product

Zelio NFC (downloadable from Google Play store)

Product compatibility

NFC enabled mobile device

Time delay type

On-delay 0.1 s...60 min Off-delay 0.1 s...60 min

Switching capacity in VA

2000 VA

NFC operating frequency

13.56 MHz

Maximum RF power transmitted

0.0002 mW

Reset time

1500 ms at maximum voltage

Maximum switching voltage

250 V AC

Minimum switching current

100 mA at 6 V

Maximum switching current

8 A AC

Supply voltage limits

166.4…576 V AC line to line 96…332.4 V AC line to neutral

Power consumption in VA

4 VA at 480 V AC 60 Hz

On-load factor

100 %

supply voltage frequency

50...60 Hz +/- 10 %

Output contacts

2 C/O

Setting accuracy of the switching threshold

+/- (1.5 % + 1 V)

Setting accuracy of time delay

+/- 3 % for 10 s...60 min time delay range +/- 300 ms for 0...10 s time delay range

Hysteresis

3 % of fixed for phase failure detection

Alarm threshold

166...576 V adjustable overvoltage and undervoltage detection (line to line) 96...332 V adjustable overvoltage and undervoltage detection (line to neutral) 5...150 V adjustable asymmetry 45...66 Hz adjustable overfrequency or underfrequency

Run-up delay at power-up max

650 ms

Maximum measuring cycle

150 ms measurement cycle as true rms value

Threshold adjustment voltage

2...20 % of Un selected

Repeat accuracy

+/- 0.5 % for input circuit +/- 3 % for time delay

Measurement error

< 0.05 %/Hz with frequency variation < 0.05 %/°C with temperature variation

Response time

<= 300 ms

Insulation resistance

> 100 MOhm at 500 V DC conforming to IEC 60255-27

[Ui] rated insulation voltage

400 V

[Uimp] rated impulse withstand voltage

4 kV during 1.2/50 µs

Dielectric test voltage

2.5 kV, 1 min AC 50 Hz conforming to IEC 60255-27

Mounting position

Any position

Connections - terminals

Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 2 x 0.5...2 x 1.5 mm² (AWG 20...AWG 16) flexible with cable end Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 1 x 0.5...1 x 2.5 mm² (AWG 20...AWG 14) flexible with cable end

Tightening torque

0.6…1 N.m conforming to IEC 60947-1 0.60…0.99 N.m conforming to IEC 60947-1

Housing material

Self-extinguishing plastic

Local signalling

LED Un: (steady), green for power ON LED R1: (steady), amber for relay energised LED R1: (blinking), amber for timing in progress LED R2: (steady), amber for relay energised LED R2: (blinking), amber for timing in progress LED PL: (steady), red for alarm phase failure triggered LED PS: (blinking), red for alarm phase sequence failure triggered LED UV: (steady), red for alarm undervoltage failure triggered LED OV: (blinking), red for alarm overvoltage failure triggered LED UF: (steady), red for alarm underfrequency failure triggered LED OF: (blinking), red for alarm overfrequency failure triggered LED ASYM: (steady), red for alarm asymmentry failure triggered

Mounting support

35 mm DIN rail conforming to IEC 60715

Electrical durability

100000 cycles

Mechanical durability

10000000 cycles

Utilisation category

AC-15 conforming to IEC 60947-5-1 DC-13 conforming to IEC 60947-5-1 AC-1 conforming to IEC 60947-4-1 DC-1 conforming to IEC 60947-4-1

[Ith] conventional free air thermal current

8 A

Contacts material

Cadmium free

Width

22.5 mm

height

90 mm

Depth

99 mm

Contacts type and composition

2 C/O

Net weight

0.125 kg

Immunity to microbreaks

10 ms

Electromagnetic compatibility

Voltage dips and interruptions immunity test - test level: 70 % (25/30 cycles) conforming to IEC 61000-4-11 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Conducted and radiated emissions class B group 1 conforming to CISPR 11 Conducted and radiated emissions class B conforming to CISPR 22 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 conforming to IEC 61000-4-3 Immunity for industrial environments conforming to IEC 61000-6-2 1 MHz damped oscillating wave - test level: 2.5 kV CM, 1 kV DM criteria B conforming to IEC 61000-4-18 Voltage dips and interruptions immunity test - test level: 0 % (0.5...25 cycles) conforming to IEC 61000-4-11 Magnetic field at power frequency - test level: 30 A/m (continuous)-300 A/m (1-3 s) level 4 conforming to IEC 61000-4-8 Surge immunity test - test level: 2 kV level 4 (differential mode) conforming to IEC 61000-4-5 Immunity for residential, commercial and light-industrial environments conforming to IEC 61000-6-1 Voltage dips and interruptions immunity test - test level: 40 % (10/12 cycles) conforming to IEC 61000-4-11 Voltage interruptions - test level: 0 % criteria C (250/300 cycles) conforming to IEC 61000-4-29 Electrical fast transient/burst immunity test - test level: 4 kV criteria B (direct) conforming to IEC 61000-4-4 Emission standard for industrial environments conforming to IEC 61000-6-4 Emission standard for residential, commercial and light-industrial environments conforming to IEC 61000-6-3 Surge immunity test - test level: 4 kV level 4 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Conducted RF disturbances level 3 conforming to IEC 61000-4-6

Standards

IEC 60255-1

product certifications

CE UL CSA CCC EAC RCM

Directives

2014/30/EU - electromagnetic compatibility 2014/35/EU - low voltage directive 2014/53/EU - radio equipment directive

Ambient air temperature for storage

-40…70 °C

Ambient air temperature for operation

-20…60 °C

Relative humidity

93…97 % at 25…55 °C conforming to IEC 60068-2-30

Vibration resistance

0.075 mm (f= 10…58.1 Hz) not in operation conforming to IEC 60068-2-6 1 gn (f= 58.1…150 Hz) not in operation conforming to IEC 60068-2-6 0.035 mm (f= 10…58.1 Hz) in operation conforming to IEC 60068-2-6 0.5 gn (f= 58.1…150 Hz) in operation conforming to IEC 60068-2-6

Shock resistance

15 gn (duration = 11 ms) for not in operation conforming to IEC 60068-2-27 5 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27

IP degree of protection

IP20 (terminals) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP40 (front panel) conforming to IEC 60529

Pollution degree

3 conforming to IEC 60664-1 3 conforming to UL 508

Overvoltage category

III conforming to IEC 60664-1 III conforming to UL 508

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

9.6 cm

Package 1 Width

2.5 cm

Package 1 Length

10.8 cm

Package 1 Weight

136.0 g

Unit Type of Package 2

S02

Number of Units in Package 2

36

Package 2 Height

15 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

5.578 kg

Unit Type of Package 3

P06

Number of Units in Package 3

576

Package 3 Height

75 cm

Package 3 Width

60 cm

Package 3 Length

80 cm

Package 3 Weight

98 kg

Warranty

18 months