Trade Price
POA
Per
1
Unit
Pack Quantity
This modular timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers.
Range of product
Harmony Timer Relays
Product or component type
Multifunction relay
Device short name
RENF22
Supported OS
Android
software version
V4.4 and above
App for product
Zelio NFC (downloadable from Google Play store)
Discrete output type
Relay
Nominal output current
8 A
Contacts type and composition
2 C/O timed contact, cadmium free 1 C/O timed and instantaneous contact, cadmium free
Time delay type
Power on-delay On-delay and off-delay Pulse delay Asymmetrical on-delay and off-delay Interval Off-delay Symmetrical flashing Safe-guard Star-delta Asymmetrical flashing Bistable
Time delay range
0.1 s...999 h
Product compatibility
NFC enabled mobile device
[Us] rated supply voltage
24...240 V AC/DC
Release input voltage
<= 2.4 V
Voltage range
0.85...1.1 Un
Maximum RF power transmitted
0.0002 mW
NFC operating frequency
13.56 MHz
Supply frequency
50...60 Hz +/- 5 %
Connections - terminals
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque
0.6…1 N.m conforming to IEC 60947-1 0.60…0.99 N.m conforming to IEC 60947-1
Housing material
Self-extinguishing
Repeat accuracy
+/- 0.2 % for 10 s...999 h time delay range +/- 0.5 % for 100 ms...10 s time delay range
Temperature drift
+/- 0.05 %/°C
Voltage drift
+/- 0.2 %/V
Setting accuracy of time delay
+/- 1 % for 1...999 h time delay range at 25 °C +/- 2 % for 1 h time delay range at 25 °C +/- 20 ms for 100 ms...10 s time delay range at 25 °C
Control signal pulse width
100 ms with load in parallel 60 ms no-load
Insulation resistance
100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time
120 ms on de-energisation
Power consumption in VA
3 VA at 240 V AC
Power consumption in W
1.5 W at 240 V DC 0.6 W at 24 V DC
Switching capacity in VA
2000 VA
Minimum switching current
10 mA at 5 V
Maximum switching current
8 A
Maximum switching voltage
250 V
Electrical durability
100000 cycles for resistive load, 8 A at 250 V, AC
Mechanical durability
10000000 cycles
Rated impulse withstand voltage
5 kV 1.2/50 µs conforming to IEC 60664-1
power on delay
100 ms
Creepage distance
4 kV/3 conforming to IEC 60664-1
Overvoltage category
III conforming to IEC 60664-1
Safety reliability data
MTTFd = 227.5 years 100 % duty cycle continuous operating condition at 30 °C
Mounting position
Any position
Mounting support
35 mm DIN rail conforming to IEC 60715
status LED
LED Un: (steady), green for power ON LED R1: (steady), amber for relay energised LED R2: (steady), amber for relay energised LED pairing: (steady), green for communication status LED Un: (fast blinking), green for diagnosis mode LED R1: (blinking), amber for timing in progress LED R2: (blinking), amber for timing in progress
Maximum communication distance
10 mm
Response time
2 s
Function available
A- Power on-delay relay-2 C/O Ac- On-delay and off-delay relay w/ control signal-2 C/O Ad- Pulse delayed relay w/ control signal-2 C/O Ah- Pulse delayed relay (single cycle) w/ control signal-2 C/O Ak- Asymmetrical on-delay and off -delay relay w/ control signal-2 C/O At- Power on-delay relay w/ pause/summation (Y1)-2 C/O B- Single interval relay w/ control signal-2 C/O Bw- Double interval relay w/ control signal-2 C/O C- Off-delay relay w/ control signal-2 C/O D- Symmetrical flashing relay (starting pulse-off)-2 C/O Di- Symmetrical flashing relay (starting pulse-on)-2 C/O Dt- Symmetrical flashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O Dit- Symmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O H- Interval relay-2 C/O Ht- Interval relay w/ pause/summation (Y1)-2 C/O Li- Asymmetrical flashing relay (starting pulse-on)-2 C/O Lt- Asymmetrical fl ashing relay (starting pulse-off) w/ pause/summation (Y1)-2 C/O Lit- Asymmetrical flashing relay (starting pulse-on) w/ pause/summation (Y1)-2 C/O N- Safe-guard relay-2 C/O O- Delayed Safe-guard relay-2 C/O P- Pulse delayed relay w/ fixed pulse length-2 C/O Pt- Pulse delayed relay w/ fixed pulse length and pause/summation-2 C/O Qt- Star-delta relay (2 CO outputs w/ split common)-2 C/O Qtt- Star-delta relay (2 CO outputs w/ split common) w/ pause/summation (Y1)-2 C/O TI- Bistable relay w/ control signal on-2 C/O Tt- Retriggerable bistable relay w/ control signal on-2 C/O W- Interval relay w/ control signal off-2 C/O L- Asymmetrical flashing relay (starting pulse-off)-2 C/O
Width
22.5 mm
Net weight
0.0904 kg
Immunity to microbreaks
10 ms
Dielectric strength
2.5 kV for 1 mA/1 minute at 50 Hz with between relay output and power supply with basic insulation with basic insulation
standards
IEC 61000-6-1 IEC 61000-6-2 IEC 61000-6-4 EN 61812-1 IEC 61000-6-3
Directives
2014/35/EU - low voltage directive 2014/53/EU - radio equipment directive 2014/30/EU - electromagnetic compatibility
product certifications
CE CSA KC UL CCC EAC DNV-GL
Ambient air temperature for operation
-20…60 °C
Ambient air temperature for storage
-40…70 °C
IP degree of protection
IP40 housing: conforming to IEC 60529 IP40 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529
Pollution degree
3 conforming to IEC 60664-1
Vibration resistance
20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn not operating for 11 ms conforming to IEC 60068-2-27 5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity
95 % at 25…55 °C
Electromagnetic compatibility
Electrostatic discharge immunity test - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge immunity test - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Fast transients immunity test - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 Electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11 Radiated emission class B conforming to EN 55022 Conducted emission class A conforming to EN 55022 Electromagnetic field immunity test - test level: 3 V/m level 2 (1.4 GHz...2 GHz) conforming to IEC 61000-4-3 Electromagnetic field immunity test - test level: 1 V/m level 1 (2...2.7 GHz) conforming to IEC 61000-4-3
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
2.4 cm
Package 1 Width
8.05 cm
Package 1 Length
9.45 cm
Package 1 Weight
103.635 g
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
4.616 kg
Unit Type of Package 3
P06
Number of Units in Package 3
640
Package 3 Height
70.0 cm
Package 3 Width
60.0 cm
Package 3 Length
80.0 cm
Package 3 Weight
84.13 kg
Warranty
18 months