Trade Price
POA
Per
1
Unit
Pack Quantity
This Harmony RE22 modular dual function timer can be set between 1 seconds and 300 hours, has an output rating of 8 amperes and it is 22.5 millimeters wide. It provides function Ak and function Akt and it is mountable on DIN rail. This modular dual function timing relay is ideal for providing timing control in automation systems such as automatic door opening, alarm, lighting in toilets and car park barriers. It has one of market slimmest form-factors with 22.5mm width, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 2-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Selectable timing range offers a one stop solution for your power management system. Dual function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0
Range of product
Harmony Timer Relays
Product or component type
Dual function relay
Discrete output type
Relay
Device short name
RE22
Nominal output current
8 A
Contacts type and composition
1 C/O timed contact, cadmium free
Time delay type
Asymmetrical on-delay and off-delay
Time delay range
30...300 h 3...30 min 30...300 s 0.05...1 s 30...300 min 10...100 s 0.3...3 s 3...30 h 1...10 s
Control type
Rotary knob Diagnostic button Potentiometer external
[Us] rated supply voltage
24...240 V AC/DC 50/60 Hz
Release input voltage
<= 2.4 V
Voltage range
0.85...1.1 Us
Supply frequency
50...60 Hz +/- 5 %
Connections - terminals
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque
0.6…1 N.m conforming to IEC 60947-1
Housing material
Self-extinguishing
Repeat accuracy
+/- 0.5 % conforming to IEC 61812-1
Temperature drift
+/- 0.05 %/°C
Voltage drift
+/- 0.2 %/V
Setting accuracy of time delay
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
Control signal pulse width
100 ms with load in parallel 30 ms
Insulation resistance
100 MOhm at 500 V DC conforming to IEC 60664-1
Recovery time
120 ms on de-energisation
Immunity to microbreaks
10 ms
Power consumption in VA
3 VA at 240 V AC
Power consumption in W
1.5 W at 240 V DC
Switching capacity in VA
2000 VA
Minimum switching current
10 mA at 5 V DC
Maximum switching current
8 A
Maximum switching voltage
250 V AC
Electrical durability
100000 cycles, 8 A at 250 V, AC-1 100000 cycles, 2 A at 24 V, DC-1
Mechanical durability
10000000 cycles
Rated impulse withstand voltage
5 kV for 1.2…50 µs conforming to IEC 60664-1
Power on delay
100 ms
Creepage distance
4 kV/3 conforming to IEC 60664-1
Overvoltage category
III conforming to IEC 60664-1
Safety reliability data
B10d = 180000 MTTFd = 194 years
Mounting position
Any position
Mounting support
35 mm DIN rail conforming to IEC 60715
Status LED
LED backlight green (steady) for dial pointer indication LED yellow (steady) for output relay energised LED yellow (fast flashing) for timing in progress and output relay de-energised LED yellow (slow flashing) for timing in progress and output relay energised
Width
22.5 mm
Net weight
0.1 kg
Dielectric strength
2.5 kV for 1 mA/1 minute at 50 Hz between relay output and power supply with basic insulation conforming to IEC 61812-1
standards
UL 508 IEC 61812-1
Directives
2006/95/EC - low voltage directive 2004/108/EC - electromagnetic compatibility
product certifications
EAC CSA UL RCM CCC GL CE
Ambient air temperature for operation
-20…60 °C
Ambient air temperature for storage
-40…70 °C
IP degree of protection
IP40 housing: conforming to IEC 60529 IP50 front face: conforming to IEC 60529 IP20 terminals: conforming to IEC 60529
Pollution degree
3 conforming to IEC 60664-1
Vibration resistance
20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn not operating for 11 ms conforming to IEC 60068-2-27 5 gn in operation for 11 ms conforming to IEC 60068-2-27
Relative humidity
95 % at 25…55 °C
Electromagnetic compatibility
Fast transients immunity test - test level: 1 kV level 3 (capacitive connecting clip) conforming to IEC 61000-4-4 Surge immunity test - test level: 1 kV level 3 (differential mode) conforming to IEC 61000-4-5 Surge immunity test - test level: 2 kV level 3 (common mode) conforming to IEC 61000-4-5 Electrostatic discharge - test level: 6 kV level 3 (contact discharge) conforming to IEC 61000-4-2 Electrostatic discharge - test level: 8 kV level 3 (air discharge) conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test - test level: 10 V/m level 3 (80 MHz...1 GHz) conforming to IEC 61000-4-3 Conducted RF disturbances - test level: 10 V level 3 (0.15...80 MHz) conforming to IEC 61000-4-6 Fast transient bursts - test level: 2 kV level 3 (direct contact) conforming to IEC 61000-4-4 Immunity to microbreaks and voltage drops - test level: 30 % (500 ms) conforming to IEC 61000-4-11 Immunity to microbreaks and voltage drops - test level: 100 % (20 ms) conforming to IEC 61000-4-11
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
8.64 cm
Package 1 Width
9.91 cm
Package 1 Length
2.79 cm
Package 1 Weight
0.1 kg
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Height
15 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
4.691 kg
Unit Type of Package 3
P06
Number of Units in Package 3
640
Package 3 Height
50 cm
Package 3 Width
80 cm
Package 3 Length
60 cm
Package 3 Weight
86.18 kg
Warranty
18 months