This Harmony RE17R timing relay can be set between 0.1 seconds and 100 hours, has an output rating of 8A, is 17.5mm wide and can be supplied with 24V DC, 24V to 240V AC. It also has 1 changeover contact SPDT (single pole double throw). It has one of market slimmest form-factors, allowing for a flexible and easy installation on DIN rail, using the same space as any modular 1-pole DIN device. It also offers a sealable cover, simple and precise settings with rotary trimmers. Multi function timer for a simple integration in hard-wired logic schematics, ideal for refurbishment of old installations without using a PLC. 0 0 0 0 0 0 0 0 0 0 0 0 0 0
Range of product
Harmony Timer Relays
Product or component type
Multifunction relay
Discrete output type
Relay
Width
17.5 mm
Device short name
RE17R
Time delay type
Ad, Ah, N, O, P, Pt, TI, Tt, W
Time delay range
6...60 s 1...10 min 0.1...1 s 1...10 h 1...10 s 6...60 min 10...100 h
Nominal output current
8 A
Contacts type and composition
1 C/O
Contacts material
Cadmium free
height
90 mm
Depth
72 mm
Control type
Selector switch front panel
[Us] rated supply voltage
24...240 V AC 50/60 Hz 24 V DC
Voltage range
0.85...1.1 Us
Supply frequency
50...60 Hz +/- 5 %
release of input voltage
10 V
Connections - terminals
Screw terminals, 1 x 0.5...1 x 3.3 mm² (AWG 20...AWG 12) solid without cable end Screw terminals, 2 x 0.5...2 x 2.5 mm² (AWG 20...AWG 14) solid without cable end Screw terminals, 1 x 0.2...1 x 2.5 mm² (AWG 24...AWG 14) flexible with cable end Screw terminals, 2 x 0.2...2 x 1.5 mm² (AWG 24...AWG 16) flexible with cable end
Tightening torque
0.6…1 N.m conforming to IEC 60947-1
Housing material
Self-extinguishing
Repeat accuracy
+/- 0.5 % conforming to IEC 61812-1
Temperature drift
+/- 0.05 %/°C
Voltage drift
+/- 0.2 %/V
Setting accuracy of time delay
+/- 10 % of full scale at 25 °C conforming to IEC 61812-1
control signal pulse width
100 ms with load in parallel typical 30 ms typical
Insulation resistance
100 MOhm at 500 V DC conforming to IEC 60664-1
Reset time
120 ms on de-energisation typical
On-load factor
100 %
Power consumption in VA
0…32 VA at 240 V AC
Maximum power consumption in W
0.6 W at 24 V DC
Minimum switching current
10 mA at 5 V DC
Maximum switching current
8 A AC/DC
Maximum switching voltage
250 V AC
Breaking capacity
2000 VA
operating frequency
10 Hz
Electrical durability
100000 cycles (8 A at 250 V AC maximum) for resistive load
Mechanical durability
10000000 cycles
Dielectric strength
2.5 kV 1 mA/1 minute 50 Hz conforming to IEC 61812-1
[Uimp] rated impulse withstand voltage
5 kV during 1.2/50 µs
power on delay
100 ms
Marking
CE
Creepage distance
4 kV/3 conforming to IEC 60664-1
Safety reliability data
MTTFd = 296.8 years B10d = 270000
Mounting position
Any position in relation to normal vertical mounting plane
Mounting support
35 mm DIN rail conforming to IEC 60715
Local signalling
LED indicator for on steady: relay energised, no timing in progress LED indicator for flashing: timing in progress 80 % ON and 20 % OFF LED indicator for pulsing: relay de-energised, no timing in progress (except function Di-D, Li-L) 5 % ON and 95 % OFF
Net weight
0.07 kg
Functionality
Multifunction
Compatibility code
RE17
Immunity to microbreaks
20 ms
standards
2006/95/EC 2004/108/EC IEC 61000-6-1 IEC 61000-6-4 IEC 61000-6-2 IEC 61000-6-3 IEC 61812-1
product certifications
cULus GL CSA
Ambient air temperature for storage
-30…60 °C
Ambient air temperature for operation
-20…60 °C
IP degree of protection
IP20 (terminal block) conforming to IEC 60529 IP40 (housing) conforming to IEC 60529 IP50 (front panel) conforming to IEC 60529
Vibration resistance
20 m/s² (f= 10…150 Hz) conforming to IEC 60068-2-6
Shock resistance
15 gn for 11 ms conforming to IEC 60068-2-27
Relative humidity
93 % without condensation conforming to IEC 60068-2-30
Electromagnetic compatibility
Electrostatic discharge immunity test: (in contact), level 3, 6 kV, conforming to IEC 61000-4-2 Electrostatic discharge immunity test: (in air), level 3, 8 kV, conforming to IEC 61000-4-2 Susceptibility to electromagnetic fields: (80 MHz to 1 GHz), level 3, 10 V/m, conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test: (capacitive connecting clip), level 3, 1 kV, conforming to IEC 61000-4-4 Electrical fast transient/burst immunity test: (direct), level 3, 2 kV, conforming to IEC 61000-4-4 1.2/50 µs shock waves immunity test: (differential mode), level 3, 1 kV, conforming to IEC 61000-4-5 1.2/50 µs shock waves immunity test: (common mode), level 3, 2 kV, conforming to IEC 61000-4-5 Conducted RF disturbances: (0.15...80 MHz), level 3, 10 V, conforming to IEC 61000-4-6 Voltage dips and interruptions immunity test: (1 cycle), 0 %, conforming to IEC 61000-4-11 Voltage dips and interruptions immunity test: (25/30 cycles), 70 %, conforming to IEC 61000-4-11 Conducted and radiated emissions: , class B, conforming to EN 55022
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.000 cm
Package 1 Width
8.300 cm
Package 1 Length
9.600 cm
Package 1 Weight
80.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
40
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
3.669 kg
Warranty
18 months