Pack Quantity
TeSys island direct starter, 3 poles, 65A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 65A and motors up to 30kW@400V / 40hp@480V. It provides motor protection functions including thermal overload (setting 3.35-65A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Range
TeSys
Product name
TeSys island
Device short name
TPRST
Product or component type
Motor starter
Motor starter type
Direct on line
Device presentation
Direct starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler
Function available
Upstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module
Product compatibility
TPRBC bus coupler TPRVM voltage interface module
Poles description
3P (3 NO)
utilisation category
AC-1 AC-2 AC-3 AC-4
Motor power kW
18.5 kW at 230 V 50 Hz (AC-3) 30 kW at 380...415 V 50 Hz (AC-3) 30 kW at 440 V 50 Hz (AC-3) 37 kW at 500 V 50 Hz (AC-3) 37 kW at 690 V 50 Hz (AC-3)
motor power HP (UL / CSA)
5 hp at 120 V AC 60 Hz for 1 phase motors 10 hp at 240 V AC 60 Hz for 1 phase motors 20 hp at 208 V AC 60 Hz for 3 phases motors 20 hp at 240 V AC 60 Hz for 3 phases motors 40 hp at 480 V AC 60 Hz for 3 phases motors 50 hp at 600 V AC 60 Hz for 3 phases motors
[Ue] rated operational voltage
<= 690 V AC 47...63 Hz
[Ie] rated operational current
65 A (at <50 °C) at <= 440 V AC-3 80 A (at <50 °C) at <= 440 V AC-1
[Ith] conventional free air thermal current
80 A (at 50 °C)
[Ui] rated insulation voltage
690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Overvoltage category
III
Thermal protection adjustment range
3.35…65 A
Thermal overload class
Class 5…30
Reset
Remotely or automatically
Irms rated making capacity
1000 A at 440 V conforming to IEC 60947
Rated breaking capacity
1000 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current
900 A 40 °C - 1 s 520 A 40 °C - 10 s 260 A 40 °C - 1 min 110 A 40 °C - 10 min
Average impedance
1.5 mOhm - Ith 80 A 50 Hz
Power dissipation per pole
6.3 W AC-3 - Ith 65 A 9.6 W AC-1 - Ith 80 A
[Uc] control circuit voltage
24 V DC supplied by the bus coupler
Current consumption
80 mA contactor sealed 500 mA contactor closing
Power dissipation in W
20.8 W at Ie AC-3
Mechanical durability
6 Mcycles
Electrical durability
1.4 Mcycles 65 A AC-3 at Ue 440 V 0.5 Mcycles 80 A AC-1 at Ue 440 V
Maximum operating rate
3600 cyc/mn AC-3
Operating time
< 80 ms closing < 80 ms opening
Safety performance level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Protection type
Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Phase sequence Rapid restart lockout Phase reversal Phase loss Phase unbalance Ground current
Monitoring type
Time device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module
Local signalling
1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)
Standards
EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Product certifications
CSA UL EAC CCC
Mounting mode
Horizontal and vertical (35 mm symmetrical DIN rail)
Connections - terminals
EverLink BTR screw connectors 1 cable(s) 1…35 mm² (AWG 16...AWG 2) rigid EverLink BTR screw connectors 2 cable(s) 1…25 mm² (AWG 16...AWG 4) rigid EverLink BTR screw connectors 1 cable(s) 1…35 mm² (AWG 16...AWG 2) flexible without cable end EverLink BTR screw connectors 2 cable(s) 1…25 mm² (AWG 16...AWG 4) flexible without cable end EverLink BTR screw connectors 1 cable(s) 1…35 mm² (AWG 16...AWG 2) flexible with cable end EverLink BTR screw connectors 2 cable(s) 1…25 mm² (AWG 16...AWG 4) flexible with cable end
Tightening torque
5 N.m - cable 1…25 mm² hexagonal 4 mm 8 N.m - cable 25…35 mm² hexagonal 4 mm
Width
55 mm
height
167 mm
Depth
125 mm
Net weight
1.248 kg
Ambient air temperature for storage
-25…70 °C
Ambient air temperature for operation
-10…50 °C without derating 50…60 °C with current derating
Relative humidity
5…95 %
Operating altitude
0...2000 m without derating
IP degree of protection
IP20
Pollution degree
2
Protective treatment
TC
Fire resistance
960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12
Shock resistance
15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance
1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility
Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.5 cm
Package 1 Width
13.5 cm
Package 1 Length
17.5 cm
Package 1 Weight
1.32 kg
Unit Type of Package 2
S02
Number of Units in Package 2
8
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
10.892 kg
Warranty
18 months