Trade Price
POA
Per
1
Unit
Pack Quantity
TeSys island direct starter, 3 poles, 25A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 25A and motors up to 11kW@400V / 15hp@480V. It provides motor protection functions including thermal overload (setting 0.5-25A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Range
TeSys
Product name
TeSys island
Device short name
TPRST
Product or component type
Motor starter
Motor starter type
Direct on line
Device presentation
Direct starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler
Function available
Upstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module
Product compatibility
TPRBC bus coupler TPRVM voltage interface module
Poles description
3P (3 NO)
utilisation category
AC-1 AC-2 AC-3 AC-4
Motor power kW
5.5 kW at 230 V 50 Hz (AC-3) 11 kW at 380...415 V 50 Hz (AC-3) 11 kW at 440 V 50 Hz (AC-3) 15 kW at 500 V 50 Hz (AC-3) 15 kW at 690 V 50 Hz (AC-3)
motor power HP (UL / CSA)
2 hp at 120 V AC 60 Hz for 1 phase motors 3 hp at 240 V AC 60 Hz for 1 phase motors 7.5 hp at 208 V AC 60 Hz for 3 phases motors 7.5 hp at 240 V AC 60 Hz for 3 phases motors 15 hp at 480 V AC 60 Hz for 3 phases motors 20 hp at 600 V AC 60 Hz for 3 phases motors
[Ue] rated operational voltage
<= 480 V AC 47...63 Hz for overvoltage cat. III <= 690 V AC 47...63 Hz for overvoltage cat. II
[Ie] rated operational current
25 A (at <50 °C) at <= 440 V AC-3 30 A (at <50 °C) at <= 440 V AC-1
[Ith] conventional free air thermal current
30 A (at 50 °C)
[Ui] rated insulation voltage
690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV conforming to IEC 60947-1
Overvoltage category
III for Ue <= 480 V II for Ue <= 690 V
Thermal protection adjustment range
0.5…25 A
Thermal overload class
Class 5…30
Reset
Remotely or automatically
Irms rated making capacity
450 A at 440 V conforming to IEC 60947
Rated breaking capacity
450 A at 440 V conforming to IEC 60947
[Icw] rated short-time withstand current
380 A 40 °C - 1 s 240 A 40 °C - 10 s 120 A 40 °C - 1 min 50 A 40 °C - 10 min
Average impedance
2 mOhm - Ith 30 A 50 Hz
Power dissipation per pole
1.25 W AC-3 - Ith 25 A 1.8 W AC-1 - Ith 30 A
[Uc] control circuit voltage
24 V DC supplied by the bus coupler
Current consumption
160 mA contactor sealed 160 mA contactor closing
Power dissipation in W
6.6 W at Ie AC-3
Mechanical durability
30 Mcycles
Electrical durability
1.65 Mcycles 25 A AC-3 at Ue 440 V 2 Mcycles 30 A AC-1 at Ue 440 V
Maximum operating rate
3600 cyc/mn AC-3
Operating time
< 100 ms closing < 30 ms opening
Safety performance level
B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1
Protection type
Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Rapid restart lockout Phase sequence Phase reversal Phase loss Phase unbalance Ground current
Monitoring type
Time device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module
Local signalling
1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)
Standards
EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Product certifications
CCC UL CSA EAC
Mounting mode
Horizontal and vertical (35 mm symmetrical DIN rail)
Connections - terminals
Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid Screw-clamp terminals 2 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid Screw-clamp terminals 1 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end Screw-clamp terminals 2 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 10) flexible with cable end Screw-clamp terminals 2 cable(s) 1.5…6 mm² (AWG 16...AWG 10) flexible with cable end
Tightening torque
2.5 N.m - with screwdriver flat Ø 6 mm 2.5 N.m - with screwdriver Philips No 3
Width
45 mm
height
121 mm
Depth
115 mm
Net weight
0.718 kg
Ambient air temperature for storage
-25…70 °C
Ambient air temperature for operation
-10…50 °C without derating 50…60 °C with current derating
Relative humidity
5…95 %
Operating altitude
0...2000 m without derating
IP degree of protection
IP20
Pollution degree
2
Protective treatment
TC
Fire resistance
960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12
Shock resistance
15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance
1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility
Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.000 cm
Package 1 Width
11.000 cm
Package 1 Length
13.000 cm
Package 1 Weight
767.000 g
Unit Type of Package 2
S02
Number of Units in Package 2
14
Package 2 Height
15.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
10.975 kg
Warranty
18 months
Datasheet