TPRST025

TI Starter 25 A / 11 kW

Trade Price

POA

Per

1

Unit

Pack Quantity

TPRST025

Information

TeSys island direct starter, 3 poles, 25A/690V. Connected to a TPRBC bus coupler it controls, protects and monitors loads up to 25A and motors up to 11kW@400V / 15hp@480V. It provides motor protection functions including thermal overload (setting 0.5-25A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of switching cycles, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Technical Specifications

Range

TeSys

Product name

TeSys island

Device short name

TPRST

Product or component type

Motor starter

Motor starter type

Direct on line

Device presentation

Direct starter connected to an automation controller through a bus coupler Operational only when connected to a bus coupler

Function available

Upstream voltage presence detection Electrical line and load protection Power and energy monitoring when connected with TPRVM voltage module

Product compatibility

TPRBC bus coupler TPRVM voltage interface module

Poles description

3P (3 NO)

utilisation category

AC-1 AC-2 AC-3 AC-4

Motor power kW

5.5 kW at 230 V 50 Hz (AC-3) 11 kW at 380...415 V 50 Hz (AC-3) 11 kW at 440 V 50 Hz (AC-3) 15 kW at 500 V 50 Hz (AC-3) 15 kW at 690 V 50 Hz (AC-3)

motor power HP (UL / CSA)

2 hp at 120 V AC 60 Hz for 1 phase motors 3 hp at 240 V AC 60 Hz for 1 phase motors 7.5 hp at 208 V AC 60 Hz for 3 phases motors 7.5 hp at 240 V AC 60 Hz for 3 phases motors 15 hp at 480 V AC 60 Hz for 3 phases motors 20 hp at 600 V AC 60 Hz for 3 phases motors

[Ue] rated operational voltage

<= 480 V AC 47...63 Hz for overvoltage cat. III <= 690 V AC 47...63 Hz for overvoltage cat. II

[Ie] rated operational current

25 A (at <50 °C) at <= 440 V AC-3 30 A (at <50 °C) at <= 440 V AC-1

[Ith] conventional free air thermal current

30 A (at 50 °C)

[Ui] rated insulation voltage

690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

Overvoltage category

III for Ue <= 480 V II for Ue <= 690 V

Thermal protection adjustment range

0.5…25 A

Thermal overload class

Class 5…30

Reset

Remotely or automatically

Irms rated making capacity

450 A at 440 V conforming to IEC 60947

Rated breaking capacity

450 A at 440 V conforming to IEC 60947

[Icw] rated short-time withstand current

380 A 40 °C - 1 s 240 A 40 °C - 10 s 120 A 40 °C - 1 min 50 A 40 °C - 10 min

Average impedance

2 mOhm - Ith 30 A 50 Hz

Power dissipation per pole

1.25 W AC-3 - Ith 25 A 1.8 W AC-1 - Ith 30 A

[Uc] control circuit voltage

24 V DC supplied by the bus coupler

Current consumption

160 mA contactor sealed 160 mA contactor closing

Power dissipation in W

6.6 W at Ie AC-3

Mechanical durability

30 Mcycles

Electrical durability

1.65 Mcycles 25 A AC-3 at Ue 440 V 2 Mcycles 30 A AC-1 at Ue 440 V

Maximum operating rate

3600 cyc/mn AC-3

Operating time

< 100 ms closing < 30 ms opening

Safety performance level

B10d = 1369863 cycles contactor with nominal load conforming to EN/ISO 13849-1 B10d = 20000000 cycles contactor with mechanical load conforming to EN/ISO 13849-1

Protection type

Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Rapid restart lockout Phase sequence Phase reversal Phase loss Phase unbalance Ground current

Monitoring type

Time device ON Time device switch ON Number of faults Number of switching cycles Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax Active and reactive power with voltage module Active and reactive energy with voltage module True power factor with voltage module

Local signalling

1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)

Standards

EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Product certifications

CCC UL CSA EAC

Mounting mode

Horizontal and vertical (35 mm symmetrical DIN rail)

Connections - terminals

Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid Screw-clamp terminals 2 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid Screw-clamp terminals 1 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end Screw-clamp terminals 2 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 10) flexible with cable end Screw-clamp terminals 2 cable(s) 1.5…6 mm² (AWG 16...AWG 10) flexible with cable end

Tightening torque

2.5 N.m - with screwdriver flat Ø 6 mm 2.5 N.m - with screwdriver Philips No 3

Width

45 mm

height

121 mm

Depth

115 mm

Net weight

0.718 kg

Ambient air temperature for storage

-25…70 °C

Ambient air temperature for operation

-10…50 °C without derating 50…60 °C with current derating

Relative humidity

5…95 %

Operating altitude

0...2000 m without derating

IP degree of protection

IP20

Pollution degree

2

Protective treatment

TC

Fire resistance

960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12

Shock resistance

15 gn (duration = 11 ms) conforming to IEC 60068-2-27

Vibration resistance

1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Electromagnetic compatibility

Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

3.000 cm

Package 1 Width

11.000 cm

Package 1 Length

13.000 cm

Package 1 Weight

767.000 g

Unit Type of Package 2

S02

Number of Units in Package 2

14

Package 2 Height

15.000 cm

Package 2 Width

30.000 cm

Package 2 Length

40.000 cm

Package 2 Weight

10.975 kg

Warranty

18 months

Document Links

Datasheet