Trade Price
POA
Per
1
Unit
Pack Quantity
TeSys island power module, 3 poles, 80A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 80A and motors up to 37kW@400V / 40hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 4-80A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).
Range of produc
TeSys
Product name
TeSys island
Device short name
TPRPM
Product or component type
Power module
device presentation
Power module connected to an automation controller through a bus coupler Operational only when connected to a bus coupler
Function available
Upstream voltage presence detection Electronic thermal overload protection Monitoring of currents Control of third party power devices when associated to TPRDG IO module
Product compatibility
TPRBC bus coupler TPRDG digital IO module TPRAN analog IO module
Poles description
3P
Motor power kW
22 kW at 230 V AC 50 Hz 37 kW at 380...415 V AC 50 Hz 37 kW at 440 V AC 50 Hz 37 kW at 500 V AC 50 Hz 37 kW at 690 V AC 50 Hz
motor power HP (UL / CSA)
5 hp at 120 V AC 60 Hz for 1 phase motors 10 hp at 240 V AC 60 Hz for 1 phase motors 20 hp at 208 V AC 60 Hz for 3 phases motors 20 hp at 240 V AC 60 Hz for 3 phases motors 40 hp at 480 V AC 60 Hz for 3 phases motors 50 hp at 600 V AC 60 Hz for 3 phases motors
[Ue] rated operational voltage
<= 690 V AC 47...63 Hz
[Ie] rated operational current
80 A (at <50 °C) at <= 440 V AC-3 80 A (at <50 °C) at <= 440 V AC-1
[Ith] conventional free air thermal current
80 A (at 50 °C)
[Ui] rated insulation voltage
690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1
[Uimp] rated impulse withstand voltage
6 kV
Overvoltage category
III
Thermal protection adjustment range
4…80 A
Thermal overload class
Class 5…30
Reset
Remotely or automatically
[Uc] control circuit voltage
24 V DC supplied by the bus coupler
Current consumption
60 mA
Power dissipation in W
2.3 W at Ie AC-3
Protection type
Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Rapid restart lockout Phase reversal Phase loss Phase sequence Phase unbalance Ground current
Monitoring type
Time device ON Number of faults Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax
Local signalling
1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)
Standards
EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1
Product certifications
CCC UL EAC CSA
Mounting mode
Horizontal and vertical (35 mm symmetrical DIN rail)
Connections - terminals
EverLink BTR screw connectors 1 cable(s) 1…35 mm² (AWG 16...AWG 2) rigid EverLink BTR screw connectors 2 cable(s) 1…25 mm² (AWG 16...AWG 4) rigid EverLink BTR screw connectors 1 cable(s) 1…35 mm² (AWG 16...AWG 2) flexible without cable end EverLink BTR screw connectors 2 cable(s) 1…25 mm² (AWG 16...AWG 4) flexible without cable end EverLink BTR screw connectors 1 cable(s) 1…35 mm² (AWG 16...AWG 2) flexible with cable end EverLink BTR screw connectors 2 cable(s) 1…25 mm² (AWG 16...AWG 4) flexible with cable end
Tightening torque
5 N.m - cable 1…25 mm² hexagonal 4 mm 8 N.m - cable 25…35 mm² hexagonal 4 mm
Width
55 mm
height
136 mm
Depth
125 mm
Net weight
0.425 kg
Ambient air temperature for storage
-25…70 °C
Ambient air temperature for operation
-10…50 °C without derating 50…60 °C with current derating
Relative humidity
5…95 %
Operating altitude
0...2000 m without derating
IP degree of protection
IP20
Pollution degree
2
Protective treatment
TC
Fire resistance
960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12
Shock resistance
15 gn (duration = 11 ms) conforming to IEC 60068-2-27
Vibration resistance
1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6
Electromagnetic compatibility
Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.5 cm
Package 1 Width
13.5 cm
Package 1 Length
17.0 cm
Package 1 Weight
495.0 g
Unit Type of Package 2
S02
Number of Units in Package 2
8
Package 2 Height
15.0 cm
Package 2 Width
30.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
4.292 kg
Warranty
18 months