TPRPM038

TI Power Interface 38A/18,5kW

Trade Price

POA

Per

1

Unit

Pack Quantity

TPRPM038

Information

TeSys island power module, 3 poles, 38A/690V. Connected to a TPRBC bus coupler it protects and monitors loads up to 38A and motors up to 18.5kW@400V / 20hp@480V. External power switching devices could be controlled if associated to a digital IO module TPRDG4X2. It provides motor protection functions including thermal overload (setting 0.76-38A, tripping class 5-30), phase loss, phase unbalance and reversal, long start (stall), locked rotor (jam), rapid cycle lockout, ground current detection. Monitoring of the load includes max/average voltages and currents, number of faults, active and reactive power/energy when associated to a TPRVM001 voltage module. Mounting on DIN rail together with the other modules of the TeSys island configuration. Multi standards certified (IEC, UL, CSA, CCC, EAC), Green Premium compliant (RoHS/REACh).

Technical Specifications

Range of product

TeSys

Product name

TeSys island

Device short name

TPRPM

Product or component type

Power module

Device presentation

Power module connected to an automation controller through a bus coupler Operational only when connected to a bus coupler

Function available

Upstream voltage presence detection Electronic thermal overload protection Monitoring of currents Control of third party power devices when associated to TPRDG IO module

Product compatibility

TPRBC bus coupler TPRDG digital IO module TPRAN analog IO module

Poles description

3P

Motor power kW

9 kW at 230 V AC 50 Hz 18.5 kW at 380...415 V AC 50 Hz 18.5 kW at 440 V AC 50 Hz 18.5 kW at 500 V AC 50 Hz 18.5 kW at 690 V AC 50 Hz

motor power HP (UL / CSA)

2 hp at 120 V AC 60 Hz for 1 phase motors 5 hp at 240 V AC 60 Hz for 1 phase motors 10 hp at 208 V AC 60 Hz for 3 phases motors 10 hp at 240 V AC 60 Hz for 3 phases motors 20 hp at 480 V AC 60 Hz for 3 phases motors 25 hp at 600 V AC 60 Hz for 3 phases motors

[Ue] rated operational voltage

<= 690 V AC 47...63 Hz

[Ie] rated operational current

38 A (at <50 °C) at <= 440 V AC-3 40 A (at <50 °C) at <= 440 V AC-1

[Ith] conventional free air thermal current

40 A (at 50 °C)

[Ui] rated insulation voltage

690 V conforming to IEC 60947-4-1 600 V conforming to UL 60947-4-1 600 V conforming to CSA C22.2 No 60947-4-1

[Uimp] rated impulse withstand voltage

6 kV

Overvoltage category

III

Thermal protection adjustment range

0.76…38 A

Thermal overload class

Class 5…30

Reset

Remotely or automatically

[Uc] control circuit voltage

24 V DC supplied by the bus coupler

Current consumption

60 mA

Power dissipation in W

0.9 W at Ie AC-3

Protection type

Thermal overload protection Motor overheat Overcurrent Undercurrent Jam Long start Stall Rapid cycle lockout Phase loss Rapid restart lockout Phase reversal Phase sequence Phase unbalance Ground current

Monitoring type

Time device ON Number of faults Number of device power cycles Average current Iavg Average voltage Vavg Max current Imax Max voltage Vmax

Local signalling

1 LED (green/red) for DS (device status) 1 LED (green/red) for LS (load status)

Standards

EN/IEC 60947-1 EN/IEC 60947-4-1 UL 60947-4-1 CSA C22.2 No 60947-4-1

Product certifications

EAC CCC CSA UL

Mounting mode

Horizontal and vertical (35 mm symmetrical DIN rail)

Connections - terminals

Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid Screw-clamp terminals 2 cable(s) 1.5…10 mm² (AWG 16...AWG 8) rigid Screw-clamp terminals 1 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end Screw-clamp terminals 2 cable(s) 2.5…10 mm² (AWG 14...AWG 8) flexible without cable end Screw-clamp terminals 1 cable(s) 1.5…10 mm² (AWG 16...AWG 10) flexible with cable end Screw-clamp terminals 2 cable(s) 1.5…6 mm² (AWG 16...AWG 10) flexible with cable end

Tightening torque

2.5 N.m - with screwdriver flat Ø 6 mm 2.5 N.m - with screwdriver Philips No 3

Width

45 mm

height

121 mm

Depth

115 mm

Net weight

0.255 kg

Ambient air temperature for storage

-25…70 °C

Ambient air temperature for operation

-10…50 °C without derating 50…60 °C with current derating

Relative humidity

5…95 %

Operating altitude

0...2000 m without derating

IP degree of protection

IP20

Pollution degree

2

Protective treatment

TC

Fire resistance

960 °C conforming to UL 94 850 °C conforming to IEC 60695-2-1 650 °C conforming to IEC 60695-2-12

Shock resistance

15 gn (duration = 11 ms) conforming to IEC 60068-2-27

Vibration resistance

1.5 mm peak to peak (f= 3…13 Hz) conforming to IEC 60068-2-6 1 gn (f= 13…200 Hz) conforming to IEC 60068-2-6

Electromagnetic compatibility

Electrostatic discharge immunity test, level 3, 8 kV air, 6 kV contact, conforming to EN/IEC 61000-4-2 Radiated RF field immunity test, level 3, 10 V/m, conforming to EN/IEC 61000-4-3 Fast transient immunity test, level 4, 4 kV, conforming to EN/IEC 61000-4-4 Surge immunity test (differential mode), level 3, 2 kV, conforming to EN/IEC 61000-4-5 Surge immunity test (common mode), level 4, 4 kV, conforming to EN/IEC 61000-4-5 Conducted RF disturbance immunity test, 20 V, conforming to EN/IEC 61000-4-6

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

5.0 cm

Package 1 Width

12.5 cm

Package 1 Length

13.0 cm

Package 1 Weight

308.0 g

Unit Type of Package 2

S02

Number of Units in Package 2

14

Package 2 Height

15.0 cm

Package 2 Width

30.0 cm

Package 2 Length

40.0 cm

Package 2 Weight

4.657 kg

Warranty

18 months