Trade Price
POA
Per
1
Unit
Pack Quantity
This QOvs is a modular residual current breaker with overcurrent protection (RCBO). It is a 1P+Ns circuit breaker with 1 protected pole, 16A In rated current and C tripping curve. The earth leakage protection class is AC type with a sensitivity of 30mA. The earth-leakage protection time delay is instantaneous. The Icn rated short circuit breaking capacity is up to 10000A according IEC 61009-2-2 standard. This product protects against short circuit, cable overload, electrical shock by indirect contact and fire hazards. It has a plug on system for fast and easy installation, no conneciton errors and more safety. It also has an operating test button on the front panel. This product is compliant with AS/NZS 61009.1 and BS EN 61009-1 standards. It has an electrical endurance going up to 5000 cycles and a mechanical endurance going up to 20000 cycles. The Ue operational voltage is 230VAC or 240VAC. The Ui rated insulation voltage is 400VAC. The Uimp rated impulse withstand voltage is 4kV. The frequency is 50/60Hz. The product color is black (RAL9005). The dimensions are (W) 19mm x (H) 110mm x (D) 85mm. The weight is 186g. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -15°C to 60°C. The storage temperature is from -40°C to 85°C.
circuit breaker application
Distribution
Range
Square D
Product name
QOvs RCBO
Product or component type
Residual current breaker with overcurrent protection (RCBO)
Poles description
1P + Ns
[In] rated current
16 A at 40 °C
Earthing system
TN
Curve code
C
Earth-leakage sensitivity
30 mA
Breaking capacity
10000 A Icn at 230/240 V AC 50/60 Hz
Number of protected poles
1
device location in system
Outgoer
Network frequency
50/60 Hz
Network type
AC
Trip unit technology
Thermal-magnetic
[Ue] rated operational voltage
230/240 V AC 50/60 Hz
Residual current tripping technology
Voltage dependent functional earth
earth-leakage protection time delay
Instantaneous
Earth-leakage protection class
Type AC
[Icw] rated short-time withstand current
Icw: 250 A during 8/20 µs impulse withstand
[Ics] rated service breaking capacity
7500 A at 230/240 V AC 50/60 Hz
Electrical insulation class
Class II
Limitation class
3
[Ui] rated insulation voltage
400 V AC 50/60 Hz
[Uimp] rated impulse withstand voltage
4 kV
Surge current
250 A
Suitability for isolation
Yes
Contact position indicator
Yes
Control type
Toggle
Local signalling
ON/OFF indication
Mounting mode
Plug-on
mounting support
Socket
Comb busbar and distribution block compatibility
NO
height
110 mm
Width
19 mm
Depth
85 mm
Net weight
186 g
Colour
Black
Mechanical durability
20000 cycles
Electrical durability
5000 cycles
Provision for padlocking
Non padlockable
Connections - terminals
Plug-in connector (top) Tunnel type terminal (bottom) 1…16 mm² rigid without cable end Tunnel type terminal (bottom) 1…10 mm² with cable end Tunnel type terminal (bottom) 1…10 mm² flexible without cable end
Wire stripping length
Power circuit: 15 mm for bottom connection
Tightening torque
Power circuit: 2 N.m bottom
earth-leakage protection
Integrated
standards
AS/NZS 61009.1 BS EN 61009-1 IEC 61009-1 IEC 61009-2-2
IP degree of protection
IP20
Tropicalisation
2
Relative humidity
95 % at 55 °C
Ambient air temperature for operation
-15…60 °C
Ambient air temperature for storage
-40…85 °C
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
10.3 cm
Package 1 Width
14.3 cm
Package 1 Length
2.7 cm
Package 1 Weight
211 g
Unit Type of Package 2
S02
Number of Units in Package 2
34
Package 2 Height
15 cm
Package 2 Width
30 cm
Package 2 Length
40 cm
Package 2 Weight
7.174 kg
Unit Type of Package 3
P12
Number of Units in Package 3
1088
Package 3 Height
70 cm
Package 3 Width
120 cm
Package 3 Length
80 cm
Package 3 Weight
229.568 kg
Warranty
18 months