59642

ACE949-2 RS485 Interface

Trade Price

POA

Per

1

Unit

Pack Quantity

59642

Information

Sepam Series 20 is a protection relay range designed for standard distribution system applications. It provides 7 types of digital current or voltage protection for standard distribution systems, each one dedicated to a single application. The communication interface is enabled with 2 wire RS485 Modbus port protocol. The rated supply voltage is 12 VDC and 24 VDC. The supply current is 16 mA for receiving mode and 40 mA for maximum in sending mode. This device can be fixed on DIN rail. Mechanical dimensions are 88 mm in height, 72 mm in width and 30 mm in depth.

Technical Specifications

Range of product

Sepam series 60 Sepam series 80 Sepam series 40 Sepam series 20 Sepam series 48 Sepam series 80 NPP

Device short name

ACE949-2

Communication port protocol

Modbus RTU network: E-LAN interface: RS485 - 2-wire Modbus RTU network: S-LAN interface: RS485 - 2-wire

Local signalling

LED for link activity (front face)

[Us] rated supply voltage

12 V DC tolerance: +/- 10 % 24 V DC tolerance: +/- 10 %

Maximum supply current

16 mA: receiving mode 40 mA: maximum in sending mode

Mounting mode

Fixed

Mounting support

Symmetrical DIN rail

Height

88 mm

Width

72 mm

Depth

30 mm

Net weight

0.1 kg

Mechanical robustness

Earthquakes in operation (level: 2) : 1 Gn (vertical axes) conforming to IEC 60255-21-3 Earthquakes in operation (level: 2) : 2 Gn (horizontal axes) conforming to IEC 60255-21-3 Jolts de-energized (level: 2) : 20 Gn/16 ms conforming to IEC 60255-21-2 Shocks de-energized (level: 2) : 27 Gn/11 ms conforming to IEC 60255-21-2 Shocks in operation (level: 2) : 10 Gn/11 ms conforming to IEC 60255-21-2 Vibrations de-energized (level: 2) : 2 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1 Vibrations in operation (level: 2) : 1 Gn, 10 Hz...150 Hz conforming to IEC 60255-21-1 Vibrations in operation (level: Fc) : 2 Hz...13.2 Hz, a = +/- 1 mm conforming to IEC 60068-2-6

Maximum cable distance between devices

10 Devices <180 m at 12 V DC 10 Devices <750 m at 24 V DC 20 Devices <160 m at 12 V DC 20 Devices <450 m at 24 V DC 25 Devices <125 m at 12 V DC 25 Devices <375 m at 24 V DC 5 Devices <1000 m at 24 V DC 5 Devices <320 m at 12 V DC

Auxiliary connection terminal

Earthing terminal: screw-type connectorcable 2.5…50 mm² <0.2 m Earthing terminal: screw-type connectortinned copper braid 6…100 mm²

Tightening torque

Earthing terminal: 2.2 N.m

Electromagnetic compatibility

1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 60255-22-1 1 MHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 2.5 kV DM, conforming to ANSI C37.90.1 100 kHz damped oscillating wave: (immunity tests-conducted disturbances), 2.5 kV CM, 1 kV DM, conforming to IEC 61000-4-12 Conducted disturbance emission: (emission tests), conforming to IEC 60255-25 Conducted disturbance emission: (emission tests), A, conforming to EN 55022 Disturbing field emission: (emission tests), conforming to IEC 60255-25 Disturbing field emission: (emission tests), A, conforming to EN 55022 Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 4 kV contact, conforming to ANSI C37.90.3 Electrostatic discharge: (immunity tests-radiated disturbances), 8 kV air, 6 kV contact, conforming to IEC 60255-22-2 Fast transient bursts: (immunity tests-conducted disturbances), 4kV, 2.5 kHz, conforming to ANSI C37.90.1 Fast transient bursts: (immunity tests-conducted disturbances), A and B, 4kV, 2.5 kHz/2 kV, 5 kHz, conforming to IEC 60255-22-4 Fast transient bursts: (immunity tests-conducted disturbances), IV, 4kV, 2.5 kHz, conforming to IEC 61000-4-4 Immunity to conducted RF disturbances: (immunity tests-conducted disturbances), III, 10 V, conforming to IEC 60255-22-6 Immunity to magnetic fields at network frequency: (immunity tests-radiated disturbances), IV, 30 A/m (continuous)-300 A/m (1-3 s), conforming to IEC 61000-4-8 Immunity to radiated fields: (immunity tests-radiated disturbances), 10 V/m, 80 MHz...1 GHz, conforming to IEC 60255-22-3 Immunity to radiated fields: (immunity tests-radiated disturbances), 35 V/m, 25 MHz...1 GHz, conforming to ANSI C37.90.2 Immunity to radiated fields: (immunity tests-radiated disturbances), III, 10 V/m, 80 MHz...2 GHz, conforming to IEC 61000-4-3 Surges: (immunity tests-conducted disturbances), III, 2 kV CM, 1 kV DM, conforming to IEC 61000-4-5 Voltage interruptions: (immunity tests-conducted disturbances), 100 % during 100 ms, conforming to IEC 60255-11

Climatic withstand

Influence of corrosion/gaz test 2 (in operation) : 21 days, 75 % RH, 25 °C, 0.5 ppm H2S, 1 ppm S02 conforming to IEC 60068-2-60 Influence of corrosion/gaz test 4 (in operation) : 21 days, 75 % RH, 25 °C, 0.01 ppm H2S, 0.2 ppm S02, 0.2 ppm NO2, 0.01 ppm CI2 conforming to IEC 60068-2-60 Continuous exposure to damp heat (in operation) : Cab: 10 days, 93 % RH, 40 °C conforming to IEC 60068-2-78 Continuous exposure to damp heat (in storage) : Cab: 56 days, 93 % RH, 40 °C conforming to IEC 60068-2-78 Continuous exposure to damp heat (in storage) : Db: 6 days, 95 % RH, 55 °C conforming to IEC 60068-2-30 Exposure to cold (in operation) : Ad: - 25 °C conforming to IEC 60068-2-1 Exposure to cold (in storage) : Ab: - 25 °C conforming to IEC 60068-2-1 Exposure to dry heat (in operation) : Bd: 70 °C conforming to IEC 60068-2-2 Exposure to dry heat (in storage) : Bb: 70 °C conforming to IEC 60068-2-2 Salt mist (in operation) : Kb/2: 6 days conforming to IEC 60068-2-52 Temperature variation with specified variation rate (in storage) : Nb: - 25 °C to 70 °C, 5 °C/min conforming to IEC 60068-2-14

Ambient air temperature for operation

-25…70 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

6.000 cm

Package 1 Width

12.100 cm

Package 1 Length

18.300 cm

Package 1 Weight

140.000 g

Unit Type of Package 2

S02

Number of Units in Package 2

8

Package 2 Height

15.000 cm

Package 2 Width

30.000 cm

Package 2 Length

40.000 cm

Package 2 Weight

1.460 kg

Unit Type of Package 3

P12

Number of Units in Package 3

64

Package 3 Height

30.000 cm

Package 3 Width

80.000 cm

Package 3 Length

120.000 cm

Package 3 Weight

25.560 kg

Warranty

18 months