This safety relay is designed for zero speed monitoring with delayed access to dangerous area. The safety relay is powered with 24V AC/DC, and equipped with a spring removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 3 safety inputs, 1 NO output configurable between 0,5s and 60s, and 2solid state diagnostic outputq with complete status information. The maximum safety level achieved by this safety relay is PLe/Category 3 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061 and SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Universal is the first choice for a broad range of simple to mid-complex machines.
Range of product
Harmony Safety Automation
Product or component type
Safety module
safety module name
XPSUVN
safety module application
For zero speed detection
function of module
Monitoring 3-phase motor Monitoring 3-phase motor with star-delta starting Monitoring 3-phase motor with variable number of poles Monitoring 3-phase motor with variable number of poles and star-delta starting Monitoring dc motor Monitoring servo motor Monitoring 3-phase motor supplied by variable speed drive Monitoring 3-phase motor supplied by servo drive Controlling enegization to open of guard switch type XCSE, XCSLE, XCSLF, XCST
Safety level
Can reach PL e/category 3 for normally open relay contact conforming to ISO 13849-1 Can reach SILCL 3 for normally open relay contact conforming to IEC 62061 Can reach SIL 3 for normally open relay contact conforming to IEC 61508
Safety reliability data
MTTFd > 30 years conforming to ISO 13849-1 Dcavg = 98.9 % conforming to ISO 13849-1 PFHd = 2.39E-9 1/h conforming to ISO 13849-1 HFT = 1 conforming to IEC 62061 PFHd = 2.39E-9 1/h conforming to IEC 62061 SFF > 99% conforming to IEC 62061 HFT = 1 conforming to IEC 61508-1 PFHd = 2.39E-9 1/h conforming to IEC 61508-1 SFF > 99% conforming to IEC 61508-1 Type = B conforming to IEC 61508-1
product certifications
TÜV cULus
[Us] rated supply voltage
24 V AC - 15...10 % 24 V DC - 20...20 %
Output type
Relay, 1 NO circuit(s), volt-free
number of additional circuits
2 solid state outputs
Power consumption in W
2.0 W
Power consumption in VA
5.5 VA
Input voltage
690 V
Input detection threshold
50 mV 65 mV 85 mV 110 mV 140 mV 180 mV 230 mV 300 mV 400 mV 500 mV
Time delay
0.5 s 1 s 2 s 3 s 5 s 8 s 12 s 20 s 35 s 60 s
[Ie] rated operational current
5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact
[Ith] conventional free air thermal current
6 A for NO relay output circuit
Associated fuse rating
6 A gG for relay output conforming to IEC 60947-1
Standards
IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard
Minimum output current
10 mA for relay output
Minimum output voltage
5 V for relay output
[Ui] rated insulation voltage
690 V phase to phase (pollution degree 2) conforming to EN/IEC 60947-1 400 V phase to earth (pollution degree 2) conforming to EN/IEC 60947-1
[Uimp] rated impulse withstand voltage
4 kV overvoltage category II conforming to EN/IEC 60947-1
Local signalling
LED green with power marking for power ON LED red with error marking for error LED yellow with state marking for status LED yellow with L12 marking for input line comparison LED yellow with L32 marking for input line comparison
Connections - terminals
Removable spring terminal block solid or flexible cable: 0.2...2.5 mm² Removable spring terminal block flexible with ferrule cable: 0.25...2.5 mm² single conductor Removable spring terminal block solid or flexible cable: 0.2...1.5 mm² twin conductor Removable spring terminal block flexible with ferrule cable: 2 x 0.25...1 mm² without cable end, with bezel Removable spring terminal block flexible with ferrule cable: 2 x 0.5...1.5 mm² with cable end, with bezel
mounting support
35 mm symmetrical DIN rail
Depth
120 mm
height
100 mm
Width
22.5 mm
Net weight
0.2 kg
IP degree of protection
IP20 (terminals) conforming to EN/IEC 60529 IP40 (housing) conforming to EN/IEC 60529 IP54 (mounting area) conforming to EN/IEC 60529
Ambient air temperature for operation
-25…55 °C
Ambient air temperature for storage
-40…70 °C
Relative humidity
5…95 % non-condensing
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
6.500 cm
Package 1 Width
13.500 cm
Package 1 Length
15.500 cm
Package 1 Weight
262.000 g
Unit Type of Package 2
S03
Number of Units in Package 2
16
Package 2 Height
30.000 cm
Package 2 Width
30.000 cm
Package 2 Length
40.000 cm
Package 2 Weight
4.969 kg
Warranty
18 months
Datasheet