Trade Price
£409.88
Per
1
Unit
EA
Pack Quantity
1
This Modicon MCM safe relay output expansion module has 4 start/restart interlock inputs, 4 relays and is fitted with captive screw clamp terminals. It is designed to monitor safety actuators for relay outputs, with a rated supply voltage of 24V DC and a maximum power dissipation of 3W. It is furnished with screw clamp terminals, removable terminal block for electrical connection. It is an IP20 rated product. The safe relay modules type XPSMCMER0004 use guided contact safety relays, each of which provides two N.O. contacts and one N.C. contact in addition to the N.C. feedback contact. This safe relay output expansion module figures LEDs on its front face, displaying the status (power supply, run, internal or external errors, inputs status, restart signal, output channels). The safe relay output modules type XPSMCMER0002 and XPSMCMER0004 do not require the backplane expansion connectors as they are directly wired to the selected OSSD. It weighs 0.3kg. Its dimension are 22.5mm (Depth), 99mm (Height) and 114.5mm (Width). Its housing is red. It is powered with 24 VDC. It is ideal for monitoring safety functions such as emergency stop, guard monitoring, perimeter guarding, position monitoring, speed monitoring and enabling movement. The safe controller CPU Modicon MCM are certified by TüV SÜD meeting the industrial safety standards of Category 4, PL e according to EN/ISO 13849-1 and SILCL 3 according to IEC/EN 61508 and IEC/EN 60261. Compatible accessory for safe relay output module is a memory card. The module instals on Omega 35mm DIN rail conforming to EN 50022. The Modicon MCM modular safety controller system provide flexibility and scalability from 8 inputs, 2 dual/4 single channel outputs up to 128 inputs, 16 dual/32 single channel outputs, up to 32 or 48 diagnostic status outputs. Modicon MCM modular safety controller system are designed to monitor multiple safety functions on and around a machine to minimise the risk of people accessing the dangerous moving parts of the machine.
Range of product
Preventa Safety automation
Product or component type
Safe relay output module
Device short name
XPSMCM
Electrical connection
Screw terminal
[Us] rated supply voltage
24 V - 20...20 % DC
Number of outputs
4 relay
Discrete output number
8 solid state at 125 mA (diagnostics)
Function of module
Monitoring safety actuators for relay output
Maximum power dissipation in W
3 W
Integrated connection type
Backplane expansion bus
Switching voltage
10 V DC
Associated fuse rating
3.5 A, slow-blow
Safety level
Can reach category 4 conforming to EN/ISO 13849-1 Can reach PL = e conforming to EN/ISO 13849-1 Can reach SIL 3 conforming to EN/IEC 61508 SILCL 3 conforming to IEC 62061
Quality labels
CE
Output type
Relay, 4 NO circuit(s), volt-free
Quantity per set
1
Switching time
12 ms
Maximum switching voltage
400 V AC 250 V DC
Minimum switching current
20 mA
Maximum switching current
6 A
Number of terminal blocks
4
Local signalling
1 LED green with PWR marking for power ON 1 LED green with RUN marking for RUN (status) 1 LED red with E IN marking for internal error 1 LED red with E EX marking for external error 2 LEDs orange with ADDR marking for node address 4 LEDs green/red with RELAY K1...K4 marking for relay contact 4 LEDs yellow with RST marking for reset
Connections - terminals
2 captive screw clamp terminals, removable terminal block 1 captive screw clamp terminals, removable terminal block
Cable cross section
0.2…1.5 mm² - AWG 24...AWG 16 flexible cablewithout cable end 0.2…2.5 mm² - AWG 24...AWG 14 flexible cablewithout cable end 0.25…1 mm² - AWG 23...AWG 18 flexible cablewith cable end, without bezel 0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, with bezel 0.25…2.5 mm² - AWG 23...AWG 14 flexible cablewith cable end, without bezel 0.5…1.5 mm² - AWG 20...AWG 16 flexible cablewith cable end, with double bezel 0.2…1 mm² - AWG 24...AWG 18 solid cablewithout cable end 0.2…2.5 mm² - AWG 24...AWG 14 solid cablewithout cable end
Mounting support
Omega 35 mm DIN rail conforming to EN 50022
Width
22.5 mm
height
99 mm
Depth
114.5 mm
Net weight
0.3 kg
standards
IEC 62061 EN/ISO 13849-1 EN/IEC 61800-5-1 EN/IEC 61508
product certifications
TÜV RCM cULus
IP degree of protection
IP20
Ambient air temperature for operation
-10…55 °C
Ambient air temperature for storage
-20…85 °C
Relative humidity
10…95 %
Pollution degree
2
[Uimp] rated impulse withstand voltage
4 kV conforming to EN/IEC 61800-5-1
Safety reliability data
B10d = 300000 utilisation category AC-15 230 V, , <3 A conforming to EN/ISO 13849-1 B10d = 750000 utilisation category AC-15 230 V, , <1 A conforming to EN/ISO 13849-1 B10d = 10000000 utilisation category DC-13 24 V, , <2 A conforming to EN/ISO 13849-1
Insulation
250 V AC between power supply and housing conforming to EN/IEC 61800-5-1
Overvoltage category
II
Electromagnetic compatibility
Electrostatic discharge immunity test - test level: 6 kV (on contact) conforming to EN/IEC 61000-4-2 Electrostatic discharge immunity test - test level: 20 kV (on air) conforming to EN/IEC 61000-4-2 Susceptibility to electromagnetic fields - test level: 10 V/m (80...1000 MHz) conforming to EN/IEC 61000-4-3 Susceptibility to electromagnetic fields - test level: 30 V/m (1.4 GHz...2 GHz) conforming to EN/IEC 61000-4-3
Vibration resistance
+/-0.35 mm (f= 10…55 Hz) conforming to EN/IEC 61496-1
Shock resistance
10 gn for 16 ms (1000 shocks on each axis) conforming to EN/IEC 61496-1
Electrical durability
20000000 cycles
Mechanical durability
20000000 cycles
Service life
20 year(s)
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
4.2 cm
Package 1 Width
12.5 cm
Package 1 Length
16.1 cm
Package 1 Weight
294.0 g
Unit Type of Package 2
S01
Number of Units in Package 2
6
Package 2 Height
15.0 cm
Package 2 Width
15.0 cm
Package 2 Length
40.0 cm
Package 2 Weight
1.991 kg
Warranty
18 months