XPSBAT12A1AC

Safety module BAT Cat.4 24V

Trade Price

£339.18

Per

1

Unit

EA

Pack Quantity

1

XPSBAT12A1AC

Information

This safety relay is designed for monitoring Emergency stop, Guard switch, Magnetic switch, RFID safety switch and Safety light curtain. The safety relay is powered with 24V AC/DC, and equipped with a screw removable terminal block. This universal safety module embeds pre-defined safety functions, or selectable safety functions via rotary selectors. This safety relay embeds 2 safety inputs, 3 control outputs, 2 NO immediate, 3 NO configurable and 1 NC configurable safety output, 1 diagnostic output. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.

Technical Specifications

Range of product

Harmony Safety Automation

Product or component type

Safety module

safety module name

XPSBAT

safety module application

For emergency stop and protective guard applications For OSSD monitoring

function of module

Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches Light curtain monitoring RFID switch Monitoring of electro-sensitive protection equipment (ESPE)

Safety level

Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1 Can reach SILCL 3 for normally open relay contact conforming to IEC 62061 Can reach SIL 3 for normally open relay contact conforming to IEC 61508 Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1 Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061 Can reach SIL 1 for normally closed relay contact conforming to IEC 61508

Safety reliability data

MTTFd > 30 years conforming to ISO 13849-1 Dcavg >= 99 % conforming to ISO 13849-1 PFHd = 0.98E-09 conforming to ISO 13849-1 for SS0 PFHd = 0.96E-09 conforming to ISO 13849-1 for SS1 HFT = 1 conforming to IEC 62061 PFHd = 0.98E-09 conforming to IEC 62061 for SS0 PFHd = 0.96E-09 conforming to IEC 62061 for SS1 SFF > 99% conforming to IEC 62061 HFT = 1 conforming to IEC 61508-1 PFHd = 0.98E-09 conforming to IEC 61508-1 for SS0 PFHd = 0.96E-09 conforming to IEC 61508-1 for SS1 SFF > 99% conforming to IEC 61508-1 Type = B conforming to IEC 61508-1

Electrical circuit type

NC pair OSSD pair

Connections - terminals

Removable spring terminal block, 0.2...2.5 mm² solid or flexible Removable spring terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable spring terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable spring terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable spring terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel

[Us] rated supply voltage

24 V AC - 15...10 % 24 V DC - 20...20 %

Synchronisation time between inputs

0.5 s 2 s

Type of start

Automatic/manual/monitored

Power consumption in W

2 W 24 V DC

Power consumption in VA

5 VA 24 V AC 50/60 Hz

Input protection type

Internal, electronic

safety outputs

2 NO immediate 1 NO configurable

safety inputs

2 positive safety input 24 V DC 5 mA

maximum wire resistance

500 Ohm

Time delay range

0...900 s off delay

Input compatibility

Normally closed circuit conforming to ISO 14119 Mechanical contact conforming to ISO 14119 OSSD pair conforming to IEC 61496-1-2 Normally closed circuit conforming to ISO 13850 3-wire proximity sensors PNP

[Ie] rated operational current

5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact

control outputs

3 on/off configurable pulsed output

Input/output type

Semiconductor output 24 V DC, 20 mA Z1, not safety-related

[Ith] conventional free air thermal current

12 A

Associated fuse rating

6 A gG for NO relay output circuit conforming to IEC 60947-1

Minimum output current

20 mA for relay output

Minimum output voltage

24 V for relay output

Maximum response time on input open

20 ms

[Ui] rated insulation voltage

250 V (pollution degree 2) conforming to EN/IEC 60947-1

[Uimp] rated impulse withstand voltage

4 kV overvoltage category II conforming to EN/IEC 60947-1

Local signalling

LED green with power marking for power ON LED red with error marking for error LED yellow with state 1 marking for safety output instantaneous LED yellow with state 2 marking for safety output delayed LED yellow with start 1 marking for start LED yellow with start 2 marking for start LED yellow with S12 marking for safety input S12 LED yellow with S22 marking for safety input S22

mounting support

35 mm symmetrical DIN rail

Depth

120 mm

height

100 mm

Width

22.5 mm

Net weight

0.350 kg

Standards

IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard

product certifications

TÜV cULus

IP degree of protection

IP20 (terminals) conforming to EN/IEC 60529 IP40 (housing) conforming to EN/IEC 60529 IP54 (mounting area) conforming to EN/IEC 60529

Ambient air temperature for operation

-25…55 °C

Ambient air temperature for storage

-25…85 °C

Relative humidity

5…95 % non-condensing

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

6.8 cm

Package 1 Width

13.8 cm

Package 1 Length

15.5 cm

Package 1 Weight

292.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

16

Package 2 Height

30 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

5.409 kg

Warranty

18 months

Document Links

Datasheet