XPSBAC34AP

Estop, guard, 48-240 V no inputs

Trade Price

£169.59

Per

1

Unit

EA

Pack Quantity

1

XPSBAC34AP

Information

This safety relay is designed for monitoring Emergency stop and Guard switch. The safety relay is powered with 48-240V AC/DC, and equipped with a screw removable terminal block. This basic safety modules embeds pre-defined safety functions. This safety relay embeds 1 control output, 4 NO safety outputs, and 2 NC diagnostic outputs. The maximum safety level achieved by this safety relay is PLe/Category 4 conforming to ISO 13849-1, SILCL 3 conforming to IEC 62061, SIL 3 conforming to IEC 61508. This safety relay weighs 0,200kg. Its dimensions are 22,5mm (Width) x 120mm (Depth) x 100mm (Height). This safety relays is suitable for applications such as Food and Beverage, Hoisting, Material Handling, Material Working, Packaging. This safe relay conforms to IEC 60947-5-1, IEC 61508-1, IEC 61508-2/-3, ISO 13849-1, IEC 62061 functional safety standards, is certified by cULus, TÜV. Harmony safety relays are compatible with Modicon logic controllers. This relay is mounted on a 35mm symmetrical DIN rail. Harmony XPS Basic and Universal safety relays are the first choice for managing single safety functions easily, typically in machines of simple to medium complexity. Harmony XPS Basic offers the most optimised solution for applications with hardwired safety modules.

Technical Specifications

Range of product

Harmony Safety Automation

Product or component type

Safety module

safety module name

XPSBAC

safety module application

For emergency stop and protective guard applications

function of module

Emergency stop button with 2 NC contacts Guard monitoring with 1 or 2 limit switches

Safety level

Can reach PL e/category 4 for normally open relay contact conforming to ISO 13849-1 Can reach SILCL 3 for normally open relay contact conforming to IEC 62061 Can reach SIL 3 for normally open relay contact conforming to IEC 61508 Can reach PL c/category 1 for normally closed relay contact conforming to ISO 13849-1 Can reach SILCL 1 for normally closed relay contact conforming to IEC 62061 Can reach SIL 1 for normally closed relay contact conforming to IEC 61508

Safety reliability data

MTTFd > 30 years conforming to ISO 13849-1 for normally open relay contact Dcavg >= 99 % conforming to ISO 13849-1 for normally open relay contact PFHd = 1.01E-09 conforming to ISO 13849-1 for normally open relay contact HFT = 1 conforming to IEC 62061 for normally open relay contact PFHd = 1.01E-09 conforming to IEC 62061 for normally open relay contact SFF > 99% conforming to IEC 62061 for normally open relay contact HFT = 1 conforming to IEC 61508-1 for normally open relay contact PFHd = 1.01E-09 conforming to IEC 61508-1 for normally open relay contact SFF > 99% conforming to IEC 61508-1 for normally open relay contact Type = B conforming to IEC 61508-1 for normally open relay contact MTTFd > 30 years conforming to ISO 13849-1 for normally closed relay contact DC > 60 % conforming to ISO 13849-1 for normally closed relay contact PFHd = 1.01E-09 conforming to ISO 13849-1 for normally closed relay contact HFT=0 conforming to IEC 62061 for normally closed relay contact PFHd = 1.01E-09 conforming to IEC 62061 for normally closed relay contact SFF > 60% conforming to IEC 62061 for normally closed relay contact HFT=0 conforming to IEC 61508-1 for normally closed relay contact PFHd = 1.01E-09 conforming to IEC 61508-1 for normally closed relay contact SFF > 60% conforming to IEC 61508-1 for normally closed relay contact Type = B conforming to IEC 61508-1 for normally closed relay contact

Electrical circuit type

NC pair

Connections - terminals

Removable screw terminal block, 0.2...2.5 mm² solid or flexible Removable screw terminal block, 0.25...2.5 mm² flexible with ferrule single conductor Removable screw terminal block, 0.2...1.5 mm² solid or flexible twin conductor Removable screw terminal block, 2 x 0.25...1 mm² flexible with ferrule without cable end, with bezel Removable screw terminal block, 2 x 0.5...1.5 mm² flexible with ferrule with cable end, with bezel

[Us] rated supply voltage

48...240 V AC - 15...10 % 48...240 V DC - 20...20 %

Synchronisation time between inputs

Unlimited

Type of start

Automatic/manual/monitored

Power consumption in W

2.0 W 48...240 V DC

Power consumption in VA

6.0 VA 48...240 V AC 50/60 Hz

Input protection type

Internal, electronic

safety outputs

4 NO + 1 NC

safety inputs

0

Input compatibility

Normally closed circuit conforming to ISO 14119 XC limit switch conforming to ISO 14119 Mechanical contact conforming to ISO 14119 Normally closed circuit conforming to ISO 13850

input terminal

Power supply

[Ie] rated operational current

5 A AC-1 for normally open relay contact 3 A AC-15 for normally open relay contact 5 A DC-1 for normally open relay contact 3 A DC-13 for normally open relay contact 3 A AC-1 for normally closed relay contact 1 A AC-15 for normally closed relay contact 3 A DC-1 for normally closed relay contact 1 A DC-13 for normally closed relay contact

control outputs

0

[Ith] conventional free air thermal current

6 A

Associated fuse rating

10 A gG for NO relay output circuit conforming to IEC 60947-1

Minimum output current

10 mA for relay output

Minimum output voltage

5 V for relay output

Response time

60 ms at 48...240 V AC/DC

[Ui] rated insulation voltage

300 V (pollution degree 2) conforming to EN/IEC 60947-1

[Uimp] rated impulse withstand voltage

4 kV overvoltage category II conforming to EN/IEC 60947-1

Local signalling

LED green with power marking for power ON LED red with error marking for error LED yellow with state marking for status LED yellow with start1 marking for start input LED yellow with start2 marking for start input

mounting support

35 mm symmetrical DIN rail

Depth

120 mm

height

100 mm

Width

22.5 mm

Net weight

0.200 kg

Ambient air temperature for operation

-25…55 °C

Standards

IEC 60947-5-1 IEC 61508-1 functional safety standard IEC 61508-2 functional safety standard IEC 61508-3 functional safety standard IEC 61508-4 functional safety standard IEC 61508-5 functional safety standard IEC 61508-6 functional safety standard IEC 61508-7 functional safety standard ISO 13849-1 functional safety standard IEC 62061 functional safety standard

product certifications

TÜV cULus

IP degree of protection

IP20 (terminals) conforming to EN/IEC 60529 IP40 (housing) conforming to EN/IEC 60529 IP54 (mounting area) conforming to EN/IEC 60529

Relative humidity

5…95 % non-condensing

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

6.5 cm

Package 1 Width

13.5 cm

Package 1 Length

15.5 cm

Package 1 Weight

305.0 g

Unit Type of Package 2

S03

Number of Units in Package 2

16

Package 2 Height

30 cm

Package 2 Width

30 cm

Package 2 Length

40 cm

Package 2 Weight

5.607 kg

Warranty

18 months

Document Links

Datasheet