A9R61240

ACTI9 IID 2P 40A 30MA A-SI-TYPE RESIDUAL

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

1

A9R61240

Information

This Acti9 iID is a modular and reliable residual current circuit breaker (RCCB). It is a 2P circuit breaker with 40A In rated current, a sensitivity of 30mA with a A-SI type protection class. This product protects against electrical shock by direct or indirect contact and fire hazards. It performs the function of disconnection of electrical circuits in case of earth fault. Its unique Visitrip indicator reduces intervention time by showing the faulty device with a mechanical indicator on front face. This product also has a VisiSafe window with a green strip on the toggle indicating full opening of the poles allowing downstream maintenance This product is compliant with EN/IEC 61008-1 standard. The (Im/IΔm) rated breaking and making short circuit capacity is 1500A. The (Inc/IΔc) conditional rated short circuit current is 10kA. The mechanical endurance is going up to 20000 cycles and electrical endurance going up to 15000 cycles. The Ue operational voltage is 220VAC to 240VAC. The Ui rated insulation voltage is 500VAC. The Uimp rated impulse withstand voltage is 6kV. The frequency is 50Hz or 60Hz. It is DIN rail mountable. The width in 9mm pitches is 4. The product colour is white (RAL9003). The dimensions are (W) 36mm x (H) 91mm x (D) 73.5mm. The weight is 0.21kg. It has an IP20 degree of protection (as per IEC/EN 60529 standard) and becomes IP40 once in modular enclosure. The operating temperature is from -25°C to 60°C. The storage temperature is from -40°C to 85°C.

Technical Specifications

Range

Acti9

Product name

Acti9 iID

Product or component type

Residual current circuit breaker (RCCB)

Device short name

iID

Poles description

2P

Neutral position

Left

[In] rated current

40 A

Network type

AC

Earth-leakage sensitivity

30 mA

earth-leakage protection time delay

Instantaneous

Earth-leakage protection class

Type A-SI (Super Immunised)

device location in system

Outgoer

Network frequency

50/60 Hz

[Ue] rated operational voltage

220...240 V AC 50/60 Hz

Residual current tripping technology

Voltage independent

Rated breaking and making capacity

Idm 1500 A Im 1500 A

Rated conditional short-circuit current

10 kA

[Ui] rated insulation voltage

500 V AC 50/60 Hz

[Uimp] rated impulse withstand voltage

6 kV

Surge current

3000 A

Contact position indicator

Yes

Control type

Toggle

Mounting mode

Clip-on

mounting support

DIN rail

9 mm pitches

4

height

91 mm

Width

36 mm

Depth

73.5 mm

Net weight

0.21 kg

Colour

White

Mechanical durability

20000 cycles

Electrical durability

AC-1: 15000 cycles

Locking options description

Padlocking device

Connections - terminals

Single terminal top or bottom 1…35 mm² rigid Single terminal top or bottom 1…25 mm² flexible Single terminal top or bottom 1…25 mm² flexible with ferrule Single terminal

Wire stripping length

14 mm for top or bottom connection

Tightening torque

3.5 N.m top or bottom

Standards

EN/IEC 61008-1

IP degree of protection

IP20 conforming to IEC 60529 IP40 (modular enclosure) conforming to IEC 60529

Pollution degree

3

Electromagnetic compatibility

8/20 µs impulse withstand, 3000 A conforming to EN/IEC 61008-1

Ambient air temperature for operation

-25…60 °C

Ambient air temperature for storage

-40…85 °C

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

4.000 cm

Package 1 Width

8.200 cm

Package 1 Length

10.000 cm

Package 1 Weight

232.700 g

Unit Type of Package 2

BB1

Number of Units in Package 2

6

Package 2 Height

8.800 cm

Package 2 Width

10.500 cm

Package 2 Length

25.000 cm

Package 2 Weight

1.457 kg

Unit Type of Package 3

S03

Number of Units in Package 3

54

Package 3 Height

30.000 cm

Package 3 Width

30.000 cm

Package 3 Length

40.000 cm

Package 3 Weight

13.532 kg

Warranty

18 months

Document Links

Datasheet