Trade Price
POA
Per
1
Unit
Pack Quantity
Range of product
Altivar Process ATV600
Product or component type
Variable speed drive
Product specific application
Process and utilities
Device short name
ATV660
Product destination
Asynchronous motors Synchronous motors
Assembly style
In floor-standing enclosure compact version
Provided equipment
Enclosure Spacial SF Graphical operating panel in the enclosure door Frequency inverter Main switch Line choke Terminal block main supply Terminal block motor
Cable entry
Bottom
Colour of enclosure
Light grey (RAL 7035)
IP degree of protection
IP23 conforming to IEC 61800-5-1
Type of cooling
Forced convection
[Us] rated supply voltage
380...415 V - 10...6 %
Supply frequency
50/60 Hz +/-5 %
Network number of phases
3 phases
Overvoltage category
III
Asynchronous motor control profile
Variable torque standard Constant torque standard Optimized torque mode
Synchronous motor control profile
Permanent magnet motor
Output voltage
<= power supply voltage
Permissible temporary current boost
1.1 x In during 60 s (normal duty) 1.5 x In during 60 s (heavy duty)
Nominal switching frequency
2.5 kHz
Switching frequency
2...8 kHz adjustable with derating factor
Speed drive output frequency
0.1…500 Hz
Motor power kW
400 kW for normal duty 315 kW for heavy duty
Continuous output current
730 A at 2.5 kHz for normal duty 590 A at 2.5 kHz for heavy duty
Maximum transient current
803 A during 60 s per 10 min (normal duty) 885 A during 60 s per 10 min (heavy duty)
Line current
681 A at 400 V (normal duty) 545 A at 400 V (heavy duty)
Apparent power
472 kVA at 400 V (normal duty) 378 kVA at 400 V (heavy duty)
Maximum THDI
<43 % full load conforming to IEC 61000-3-12
Short-circuit protection
Internal: 315.0 A 3 aR fuse Upstream: 800.0 A gG fuse (normal duty) Upstream: 630.0 A gG fuse (heavy duty)
Energy efficiency ratio
0.98
Power dissipation in W
9900 W, total (normal duty) 7370 W, total (heavy duty) 1120 W, control part (normal duty) 770 W, control part (heavy duty)
Volume of cooling air
1740 m3/h for power 280 m3/h for control
Noise level
71 dB conforming to 86/188/EEC - physical agents (noise) directive
Prospective line Isc
50 kA for 100 ms
Electrical connection
Removable screw terminals, clamping capacity: 0.5...1.5 mm² for control M12 bar for main supply M12 bar for motor
Motor recommanded cable cross section
3 x (3 x 120 mm²) (heavy duty) 3 x (3 x 185 mm²) (normal duty) 4 x (3 x 120 mm²) (normal duty) 4 x (3 x 95 mm²) (heavy duty)
Width
800 mm
Height
2150 mm
Depth
664 mm
Net weight
650 kg
number of preset speeds
16 preset speeds
Communication port protocol
Modbus TCP Modbus serial EtherNet/IP
Option card
Slot A: communication module, Profibus DP V1 Slot A: communication module, PROFINET Slot A: communication module, DeviceNet Slot A: communication module, Modbus TCP/EtherNet/IP Slot A: communication module, CANopen daisy chain RJ45 Slot A: communication module, CANopen SUB-D 9 Slot A: communication module, CANopen screw terminals Slot A/slot B: digital and analog I/O extension module Slot A/slot B: output relay extension module
Safety function
STO (safe torque off), level SIL 3 for <= 100 ms
EMC filter
Integrated conforming to EN/IEC 61800-3, category C3, shielded cable with 150 m Integrated conforming to EN/IEC 61800-3, category C4, unshielded cable with 250 m
Motor slip compensation
Can be suppressed Automatic whatever the load Adjustable Not available in permanent magnet motor law
Acceleration and deceleration ramps
S, U or customized Linear adjustable separately from 0.01 to 9000 s
Braking to standstill
By DC injection
Protection type
Motor: thermal protection Motor: safe torque off Motor: motor phase break Drive: thermal protection Drive: safe torque off Drive: overheating Drive: overcurrent (between output phases and earth) Drive: overload (output) Drive: short-circuit protection Drive: motor phase break Drive: overvoltage (DC bus) Drive: line supply overvoltage Drive: line supply undervoltage Drive: line supply phase loss Drive: overspeed Drive: break on the control circuit Drive: short-circuit protection with semi-conductor fuse (main supply) Drive: fan monitoring
Frequency resolution
Display unit: 0.1 Hz Analog input: 0.012/50 Hz
Connector type
RJ45 (on the control block) for Modbus serial RJ45 (on the control block) for Ethernet IP/Modbus TCP
Physical interface
2-wire RS 485 for Modbus serial
Transmission frame
RTU for Modbus serial
Transmission rate
10/100 Mbit/s for Ethernet IP/Modbus TCP 4.8, 9.6, 19.2, 38.4 kbit/s for Modbus serial
Exchange mode
Half duplex, full duplex, autonegotiation Ethernet IP/Modbus TCP
Data format
8 bits, configurable odd, even or no parity for Modbus serial
Type of polarization
No impedance for Modbus serial
Number of addresses
1…247 for Modbus serial
Method of access
Slave Modbus TCP
Supply
External supply for digital inputs: 24 V DC (10…30 V), <1.25 mA, protection type: overload and short-circuit protection Internal supply for reference potentiometer (1 to 10 kOhm): 10.5 V DC +/- 5 %, <10 mA, protection type: overload and short-circuit protection Internal supply for digital inputs and STO: 24 V DC (21…27 V), <200 mA, protection type: overload and short-circuit protection
Local signalling
LCD display unit front door operation function, status and configuration
analogue input number
3
Analogue input type
AI1, AI2, AI3 software-configurable voltage: 0...10 V DC, impedance: 30 kOhm, resolution 12 bits AI1, AI2, AI3 software-configurable current: 0...20 mA, impedance: 250 Ohm, resolution 12 bits
Discrete input number
8
Discrete input type
DI1...DI6 programmable, 24 V DC (<= 30 V), impedance: 3.5 kOhm DI5, DI6 programmable as pulse input: 0…30 kHz, 24 V DC (<= 30 V) STOA, STOB safe torque off, 24 V DC (<= 30 V), impedance: > 2.2 kOhm
Input compatibility
DI1...DI6: discrete input level 1 PLC conforming to EN/IEC 61131-2 DI5, DI6: discrete input level 1 PLC conforming to IEC 65A-68 STOA, STOB: discrete input level 1 PLC conforming to EN/IEC 61131-2
Discrete input logic
Positive logic (source) (DI1...DI6), < 5 V (state 0), > 11 V (state 1) Negative logic (sink) (DI1...DI6), > 16 V (state 0), < 10 V (state 1) Positive logic (source) (DI5, DI6), < 0.6 V (state 0), > 2.5 V (state 1) Positive logic (source) (STOA, STOB), < 5 V (state 0), > 11 V (state 1)
analogue output number
2
Analogue output type
Software-configurable voltage AQ1, AQ2: 0...10 V DC impedance 470 Ohm, resolution 10 bits Software-configurable current AQ1, AQ2: 0...20 mA, resolution 10 bits
Sampling duration
2 ms +/- 0.5 ms (DI1...DI4) - discrete input 5 ms +/- 1 ms (DI5, DI6) - discrete input 5 ms +/- 1 ms (AI1, AI2, AI3) - analog input 10 ms +/- 1 ms (AQ1, AQ2) - analog output
Accuracy
+/- 0.6 % AI1, AI2, AI3 for a temperature variation 60 °C analog input +/- 1 % AQ1, AQ2 for a temperature variation 60 °C analog output
Linearity error
AI1, AI2, AI3: +/- 0.15 % of maximum value for analog input AQ1, AQ2: +/- 0.2 % for analog output
Relay output number
3
Relay output type
Configurable relay logic R1: fault relay NO/NC electrical durability 100000 cycles Configurable relay logic R2: sequence relay NO electrical durability 100000 cycles Configurable relay logic R3: sequence relay NO electrical durability 100000 cycles
Refresh time
Relay output (R1, R2, R3): 5 ms (+/- 0.5 ms)
Minimum switching current
Relay output R1, R2, R3: 5 mA at 24 V DC
Maximum switching current
Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 250 V AC Relay output R1, R2, R3 on resistive load, cos phi = 1: 3 A at 30 V DC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 250 V AC Relay output R1, R2, R3 on inductive load, cos phi = 0.4 and L/R = 7 ms: 2 A at 30 V DC
Isolation
Between power and control terminals
Insulation resistance
> 1 MOhm 500 V DC for 1 minute to earth
Operating position
Vertical +/- 10 degree
Electromagnetic compatibility
Electrostatic discharge immunity test level 3 conforming to IEC 61000-4-2 Radiated radio-frequency electromagnetic field immunity test level 3 conforming to IEC 61000-4-3 Electrical fast transient/burst immunity test level 4 conforming to IEC 61000-4-4 1.2/50 µs - 8/20 µs surge immunity test level 3 conforming to IEC 61000-4-5 Conducted radio-frequency immunity test level 3 conforming to IEC 61000-4-6
Pollution degree
2 conforming to EN/IEC 61800-5-1
Vibration resistance
1.5 mm peak to peak (f= 3…10 Hz) conforming to IEC 60068-2-6 0.6 gn (f= 10…200 Hz) conforming to IEC 60068-2-6 3M3 conforming to IEC 60721-3-3
Shock resistance
4 gn for 11 ms conforming to IEC 60068-2-27 3M2 conforming to IEC 60721-3-3
Relative humidity
5…95 % without condensation conforming to IEC 60068-2-3
Ambient air temperature for operation
-10…0 °C without derating (with option enclosure heating) 0…40 °C without derating 40…50 °C with derating factor
Ambient air temperature for storage
-25…70 °C
Operating altitude
< 1000 m without derating 1000...2000 m with current derating 1 % per 100 m 2000...3800 m with current derating 1 % per 100 m for TT earthing system 2000...3800 m with current derating 1 % per 100 m for TN earthing system 2000...3800 m with current derating 1 % per 100 m for IT earthing system 3800...4800 m with current derating 1 % per 100 m for TT earthing system 3800...4800 m with current derating 1 % per 100 m for TN earthing system
Environmental characteristic
Chemical pollution resistance class 3C3 conforming to EN/IEC 60721-3-3 Dust pollution resistance class 3S3 conforming to EN/IEC 60721-3-3 Humidity resistant class 3K3 conforming to EN/IEC 60721-3-3
standards
EN/IEC 60204-1 EN/IEC 61800-2 EN/IEC 61800-3 EN/IEC 61800-5-1
Product certifications
ATEX EAC C-Tick
Marking
CE
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
215 cm
Package 1 Width
66.9 cm
Package 1 Length
80 cm
Package 1 Weight
700 kg
Unit Type of Package 2
CAR
Number of Units in Package 2
1
Package 2 Height
230 cm
Package 2 Width
80 cm
Package 2 Length
95 cm
Package 2 Weight
670 kg
Warranty
18 months