ZBE201

EARLY MAKE NO CONTACT

Trade Price

POA

Per

1

Unit

EA

Pack Quantity

5

ZBE201

Information

This Harmony ZB, single contact block for staggered early make contact uses screw-clamp terminals. It is compatible with Harmony XB4 and XB5 control and signaling units. This contact block, uses for staggered early make contact operation, allows fast and easy replacement and configuration of specific control and signaling products. It is easily installed and replaced on XB4 and XB5 control and signalling units and connects to control circuits with screw-clamp connections. It protects operators from unexpected contact with live circuits thanks to its IP20 protection index. 1 million cycle high endurance under 6A load allows less maintenance and damage in your installation. It has clear color scheme for NO and NC contact block types. Its wide range of operating temperatures from -40°C to 70°C allows versatility in usage of product.

Technical Specifications

Range of product

Harmony XB4 Harmony XB5

Product or component type

Contact block

Device short name

ZBE

Sale per indivisible quantity

5

IP degree of protection

IP20 conforming to IEC 60529

contact operation

Early make

Contact block type

Single

contacts usage

Staggered contacts

Connections - terminals

Screw clamp terminals, <= 2 x 1.5 mm² with cable end conforming to IEC 60947-1 Screw clamp terminals, >= 1 x 0.22 mm² without cable end conforming to IEC 60947-1

Net weight

0.011 kg

Contacts type and composition

1 NO

Positive opening

Without

Operating travel

2.6 mm (NO changing electrical state) 4.3 mm (total travel)

Operating force

2.3 N NO changing electrical state

Mechanical durability

10000000 cycles

Tightening torque

0.8…1.2 N.m conforming to IEC 60947-1

Shape of screw head

Cross compatible with pozidriv No 1 screwdriver Slotted compatible with flat Ø 4 mm screwdriver Slotted compatible with flat Ø 5.5 mm screwdriver

Contacts material

Silver alloy (Ag/Ni)

Short-circuit protection

10 A cartridge fuse type gG conforming to IEC 60947-5-1

[Ith] conventional free air thermal current

10 A conforming to IEC 60947-5-1

[Ui] rated insulation voltage

600 V (pollution degree 3) conforming to IEC 60947-1

[Uimp] rated impulse withstand voltage

6 kV conforming to IEC 60947-1

[Ie] rated operational current

3 A at 240 V, AC-15, A300 conforming to IEC 60947-5-1 6 A at 120 V, AC-15, A300 conforming to IEC 60947-5-1 0.1 A at 600 V, DC-13, Q300 conforming to IEC 60947-5-1 0.27 A at 250 V, DC-13, Q300 conforming to IEC 60947-5-1 0.55 A at 125 V, DC-13, Q300 conforming to IEC 60947-5-1

Electrical durability

1000000 cycles, AC-15, 2 A at 230 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 3 A at 120 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, AC-15, 4 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.2 A at 110 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C 1000000 cycles, DC-13, 0.5 A at 24 V, operating rate <3600 cyc/h, load factor: 0.5 conforming to IEC 60947-5-1 appendix C

Mounting of block

Front mounting

Electrical composition code

C1 (quantity <= 9) C2 (quantity <= 7) C3 (quantity <= 6) C4 (quantity <= 4) C5 (quantity <= 5) C6 (quantity <= 3) C7 (quantity <= 4) C8 (quantity <= 2) C9 (quantity <= 3) C12 (quantity <= 6) M1 (quantity <= 6) M2 (quantity <= 4) M3 (quantity <= 4) M5 (quantity <= 2) M6 (quantity <= 2) M7 (quantity <= 6) M8 (quantity <= 4) M9 (quantity <= 2) SF1 (quantity <= 3) SF2 (quantity <= 2) MF1 (quantity <= 2) MF2 (quantity <= 2) C10 (quantity <= 2) M4 (quantity <= 2) C13 (quantity <= 1)

Protective treatment

TH

Ambient air temperature for storage

-40…70 °C

Ambient air temperature for operation

-40…70 °C

standards

UL 508 IEC 60947-5-4 IEC 60947-1 JIS C8201-5-1 IEC 60947-5-1 CSA C22.2 No 14 JIS C8201-1

product certifications

DNV GOST BV UL CCC GL CSA LROS (Lloyds register of shipping)

Vibration resistance

5 gn (f= 2…500 Hz) conforming to IEC 60068-2-6

Shock resistance

30 gn (duration = 18 ms) for half sine wave acceleration conforming to IEC 60068-2-27 50 gn (duration = 11 ms) for half sine wave acceleration conforming to IEC 60068-2-27

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

0.100 cm

Package 1 Width

4.300 cm

Package 1 Length

4.000 cm

Package 1 Weight

9.000 g

Unit Type of Package 2

BB1

Number of Units in Package 2

5

Package 2 Height

5.600 cm

Package 2 Width

4.300 cm

Package 2 Length

4.000 cm

Package 2 Weight

52.000 g

Unit Type of Package 3

S03

Number of Units in Package 3

800

Package 3 Height

30.000 cm

Package 3 Width

30.000 cm

Package 3 Length

40.000 cm

Package 3 Weight

8.797 kg

Warranty

18 months

Document Links

Datasheet