Trade Price
POA
Per
1
Unit
Pack Quantity
This Harmony RUM universal plug-in relay uses cylindrical pins, has a control coil voltage of 24V DC and has 3 changeover contacts triple pole double throw with a rating of 10A." "It provides a complete system solution for the most demanding applications." "It also offers one-step lockable test button and “Power On” LED for readiness." "It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere." "The product is IP40 and has a transparent cover allowing operator to visually inspect the status of contacts." "Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs)." "Status display with LED, clearly signal both in the day and night." 0 0 0 0 0 0 0 0 0
Range of product
Harmony Electromechanical Relays
Series name
Universal
Product or component type
Plug-in relay
Device short name
RUM
Contacts type and composition
3 C/O
[Uc] control circuit voltage
24 V DC
[Ithe] conventional enclosed thermal current
10 A at -40…55 °C
Status LED
With
Control type
Lockable test button
Utilisation coefficient
20 %
Shape of pin
Cylindrical
[Ui] rated insulation voltage
250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL
[Uimp] rated impulse withstand voltage
4 kV (1.2/50 µs)
Contacts material
AgNi
[Ie] rated operational current
10 A at 277 V AC conforming to UL 10 A at 30 V DC conforming to UL 10 A at 277 V AC (same polarity) conforming to CSA 10 A at 30 V DC conforming to CSA 5 A at 250 V AC (NC) conforming to IEC 5 A at 28 V DC (NC) conforming to IEC 10 A at 250 V AC (NO) conforming to IEC 10 A at 28 V DC (NO) conforming to IEC
Maximum switching voltage
250 V conforming to IEC
Resistive rated load
10 A at 250 V AC 10 A at 28 V DC
Maximum switching capacity
2500 VA/280 W
Minimum switching capacity
170 mW at 10 mA, 17 V
Operating rate
<= 18000 cycles/hour no-load <= 1200 cycles/hour under load
Mechanical durability
5000000 cycles
Electrical durability
100000 cycles for resistive load
Average coil consumption in W
1.4 W
Drop-out voltage threshold
>= 0.1 Uc DC
Operate time
20 ms at nominal voltage
Release time
20 ms at nominal voltage
Average coil resistance
470 Ohm at 20 °C +/- 15 %
Rated operational voltage limits
19.2...26.4 V DC
Protection category
RT I
Test levels
Level A group mounting
Safety reliability data
B10d = 100000
Operating position
Any position
Net weight
0.086 kg
Device presentation
Complete product
Dielectric strength
1500 V AC between contacts with micro disconnection 2500 V AC between coil and contact with reinforced 2000 V AC between poles with basic
product certifications
EAC UL CSA
standards
IEC 61810-1 CSA C22.2 No 14 UL 508
Ambient air temperature for storage
-40…85 °C
Ambient air temperature for operation
-40…55 °C
Vibration resistance
3 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles in operation 4 gn, amplitude = +/- 1 mm (f = 10…150 Hz)5 cycles not operating
IP degree of protection
IP40
Shock resistance
10 gn (duration = 11 ms) for in operation conforming to IEC 60068-2-27 10 gn (duration = 11 ms) for not operating conforming to IEC 60068-2-27
Pollution degree
2
Unit Type of Package 1
PCE
Number of Units in Package 1
1
Package 1 Height
3.6 cm
Package 1 Width
3.5 cm
Package 1 Length
6.9 cm
Package 1 Weight
90 g
Unit Type of Package 2
BB1
Number of Units in Package 2
10
Package 2 Height
4 cm
Package 2 Width
14.6 cm
Package 2 Length
20 cm
Package 2 Weight
964 g
Unit Type of Package 3
S02
Number of Units in Package 3
60
Package 3 Height
15 cm
Package 3 Width
30 cm
Package 3 Length
40 cm
Package 3 Weight
6.426 kg
Warranty
18 months