RXG11B7

1CO 10A RELAY LTB-LED 24VAC

Trade Price

POA

Per

1

Unit

Pack Quantity

RXG11B7

Information

This Harmony RXG plug-in relay socket has a coil control voltage of 24V AC and has 1 changeover contact SPDT (single pole double throw) with a rating of 10A." "It has large choice of number of contacts for high rated current use." "It also offers lockable test button." "It helps to reduce the size of enclosures and increase machine reliability, you can mount nearly everywhere thanks to its 16mm width." "Workability for hard-wired logic automated systems to complement the functions of industrial programmable logic controllers (PLCs)." 0 0 0 0 0 0 0 0 0 0 0

Technical Specifications

Range of product

Harmony Electromechanical Relays

Series name

Interface relay

Product or component type

Plug-in relay

Device short name

RXG

Contacts type and composition

1 C/O

Status LED

Without

Contacts material

Silver alloy (AgSnO2In2O3)

Maximum contact resistance

100 mOhm

[Ithe] conventional enclosed thermal current

10 A at -40…55 °C

[Ie] rated operational current

10 A at 30 V (DC) conforming to UL 10 A at 30 V (DC) conforming to IEC 10 A at 250 V (AC) conforming to IEC 10 A at 250 V (AC) conforming to UL

Maximum switching voltage

250 V AC 30 V DC

Load current

10 A at 250 V AC

Maximum switching capacity

2500 VA

Minimum switching capacity

500 mW at 100 mA, 5 V DC

Operating rate

<= 1800 cycles/hour under load <= 18000 cycles/hour no-load

Utilisation coefficient

20 %

Mechanical durability

10000000 cycles

Electrical durability

100000 cycles for NO resistive load at 55 °C 100000 cycles for NC resistive load at 55 °C

[Ui] rated insulation voltage

250 V conforming to IEC 300 V conforming to CSA 300 V conforming to UL

[Uimp] rated impulse withstand voltage

6 kV 1.2/50 µs

Dielectric strength

1000 V AC between contacts with micro disconnection 5000 V AC between coil and contact with reinforced insulation

Coil resistance

260 Ohm +/- 10 %

Insulation resistance

1000 MOhm at 500 V DC

Test levels

Level A group mounting

Mounting position

Any position

Average consumption in VA

0.82 VA 60 Hz

Drop-out voltage threshold

>= 0.3 Uc AC

Control circuit voltage limits

0.8...1.1 Uc AC

Coil insulation class

Class F

Operate time

20 ms

Release time

20 ms

[Uc] control circuit voltage

24 V AC 50/60 Hz

Safety reliability data

B10d = 100000

colour of cover

Standard

Control type

Lockable test button

Local signalling

Flag

Torque value

0.8 N.m

Net weight

0.02 kg

Device presentation

Complete product

Vibration resistance

3 gn, amplitude = +/- 0.75 mm (f = 10…150 Hz)in operation 5 gn, amplitude = +/- 0.75 mm (f = 10…150 Hz)not in operation

IP degree of protection

IP40

Shock resistance

20 gn in operation 100 gn not in operation

Protection category

RT I

standards

CSA C22.2 No 14 UL 508 IEC 61810-1

product certifications

CE UL EAC CSA DNV-GL

Pollution degree

2

Overvoltage category

III

Ambient air temperature for storage

-40…85 °C

Ambient air temperature for operation

-40…70 °C

Relative humidity

10…85 %

Unit Type of Package 1

PCE

Number of Units in Package 1

1

Package 1 Height

3.45 cm

Package 1 Width

9.25 cm

Package 1 Length

8.6 cm

Package 1 Weight

22.1 g

Unit Type of Package 2

BB1

Number of Units in Package 2

10

Package 2 Height

3.3 cm

Package 2 Width

8.2 cm

Package 2 Length

9.1 cm

Package 2 Weight

229 g

Unit Type of Package 3

S01

Number of Units in Package 3

200

Package 3 Height

15 cm

Package 3 Width

15 cm

Package 3 Length

40 cm

Package 3 Weight

4.89 kg

Warranty

18 months

Document Links

Datasheet