This is the digital module "ANSI 81 - Under/over frequency protection" for Micrologic X trip unit on MasterPact MTZ offer. A digital module is an advanced function that can be uploaded in Micrologic X trip unit at any stage of the product life cycle. Digital modules allow you to customize MasterPact MTZ circuit breaker to your specific needs. The digital modules are available 24/7 on the Schneider Electric GoDigital store (godigital.schneider-electric.com). The upload of the digital modules is made without interrupting power, using EcoStruxure Power Commission software and a USB cable. This digital module is used to generate either an alarm or a trip for under frequency and over frequency protections. The protection picks up when the frequency reaches its upper or lower limit. The Under/Over frequency protection requires the Micrologic X control unit to be supplied by an external 24 V dc power supply. The Micrologic X control unit firmware (greater than or equal to V003.012.xxx) is compatible with this digital module. Earlier firmware versions need to be upgraded. The benefit is to provide under frequency and over frequency protections that are suitable for generator use during abnormal or critical situations (load shedding, source changeover, emergency generator starting).
Range
MasterPact
Product or component type
Application
Application description
Under/over frequency ANSI 81
Range compatibility
MasterPact MTZ1 circuit breaker MasterPact MTZ2 circuit breaker MasterPact MTZ3 circuit breaker
Product compatibility
control unit MicroLogic 2.0 X control unit MicroLogic 3.0 X control unit MicroLogic 5.0 X control unit MicroLogic 6.0 X control unit MicroLogic 7.0 X control unit MicroLogic 2.0 Xi control unit MicroLogic 3.0 Xi control unit MicroLogic 5.0 Xi control unit MicroLogic 6.0 Xi control unit MicroLogic 7.0 Xi
function of module
Protection
Service description
Circuit breaker trips when the frequency exceeds the settings Under/over frequency protection monitors frequency
Service benefits
Protection of the generators Enable action to be initiated to safeguard the operation of the installation Typical actions: load shedding, source changeover, emergency generator starting
Energy management
Network management (option)
Protection type
Underfrequency ANSI code: 81 (option) Overfrequency ANSI code: 81 (option)